18
How to correct a fault.
Smoke entering room
•
Poor draught in the chimney.
•
Check that the flue and chimney are not blocked.
•
Check that the chimney height is correct in accordance with the surroundings.
Glass and/or chimney soot:
•
Wood is too wet.
•
There is insufficient combustion air (secondary air).
•
You have closed the kindling air too quickly when you started the fire.
•
There must always be clear flames in the combustion chamber.
The stove is not heating the room:
•
The wood is too wet (all the energy is being used up in drying the wood) or the wood is
poor quality.
•
Check that the smoke guide plate is positioned correctly (free passage for smoke).
•
Insufficient combustion air (secondary air).
The fire burns too intensely:
•
The gasket in the door or ash pan does not seal (it must be replaced).
•
The chimney draught is too powerful (fit a damper in the chimney).
•
Check that the kindling air is closed.
The shaker grate is stuck:
•
Check that a piece of wood or similar is not stuck in the grate.
•
Check that the shaker grate bar is in the correct position.
Recycling
Packaging
In consideration of the environment, the packaging should be disposed of in accor-
dance with local regulations for the disposal of waste. The packaging is 100% recy-
clable.
Ceramic glass
Ceramic glass must be taken to the local recycling station and recycled with other
ceramic and porcelain, where it is sent to a waste disposal facility.
Vermiculite
Vermiculite panels from the wood-burning stove must be taken to the recycling sta-
tion, where they will be sent to a waste disposal facility.
Summary of Contents for Lyon
Page 19: ...19...