background image

15 

14 

The 

MIGHTY MEDIC Vapor-

izer ensures the highly effec-
tive, safe, and fast-acting ap-

plication of cannabinoids. The patient 
must undergo a medical examination 
before the beginning of treatment.
The 

MIGHTY MEDIC Vaporizer is not 

intended for use in children and youth 
under age 18. Adults may use the de-
vice following the Instructions for Use 
or physician’s instructions. 

Due to hygienic reasons, the 
MIGHTY MEDIC Vaporizer 
may be operated only with at-

tached (disposable) Lip Piece on the 
Mouthpiece (see Chapter 8.1. „Dis-
posable Lip Piece for Hygienic Use“ 
from page 29 onwards). 

The device is not to be used, if 
the user has respiratory tract 
or lung conditions. Depending 

on the density, the vapor could irritate 
respiratory tracts or lungs, which can 
lead to coughing. 
The application and inhalation is de-
scribed in Chapter 8.2. “Cooling Unit 
with Mouthpiece” on page 30.
Before every use by another person, 
the Cooling Unit and the Vaporizer 
must be cleaned thoroughly (see in-
formation on the Cooling Unit and 
Vaporizer from page 28 onwards). 

Please note that damaged or 
brittle Lip Pieces are not to be 
used. 

At a certain dosage, cannabis 
can have a psychotropic 
(mind-altering) effect.

Thus, there is a potential for abuse, 
which governments in nearly all coun-
tries of the world counteract with cor-
responding laws. 
Use only medicinal hemp flowers 
(cannabis flos) prescribed by your 
physician and purchased from a phar-
macy. Otherwise you may be at risk of 
breaking the law. 
In case of doubt, ask your physician, 
pharmacist, or the responsible au-
thorities about the current laws at your 
place of residence. 
Cannabinoids vaporize at tempera-
tures over 180°C (356°F) and then 
form an aerosol with an average drop-
let size (MMAD) of 0.64 µm (microm-
eter) that can be inhaled and respired. 
The droplets are absorbed in the al-
veoli and enter the bloodstream (sys-
temic absorption). 
When cannabinoids are inhaled, the 
onset of the effect takes approx. 1-2 
min. and the effects last for 2-4 hours. 
Our Service Centre is available to an-
swer your questions and receive your 
comments and suggestion concern-
ing the 

MIGHTY MEDIC Vaporizer. 

You may download the cur-
rent Instructions for Use for 
the 

MIGHTY MEDIC Vaporiz-

4. IMPORTANT REMARKS

4. IMPORTANT REMARKS

er on www.vapormed.com. Here you 
will find the up-to-date information to 
the current state of research. 
If questions occur about the medical 
use of cannabinoids or cannnabis 
please contact your doctor, pharma-
cist or manufacturer of medical hemp 
flowers (Cannabis flos). 

Summary of Contents for MIGHTY MEDIC

Page 1: ...INSTRUCTIONS FOR USE Read carefully before using the device and save these instuctions...

Page 2: ...GHTY MEDIC Vaporizer 17 5 1 Unpacking 17 5 2 Power Connection 17 5 3 Application and Operation 18 5 4 Charging the Battery 18 5 5 Heating Up 20 5 6 Temperature Setting 21 5 7 Reset to Default Settings...

Page 3: ...zer 36 10 1 Cleaning of the MIGHTY MEDIC Vaporizer and the Power Adapter 36 10 2 Care and Maintenance Storage Disposal 36 10 3 Troubleshooting Periodic Safety Checks 37 10 4 Technical Specifications 3...

Page 4: ...have an average expected operating life of approx 500 operating hours approx 2 years For exchanging the batteries please contact our Service Center Service Contact in case of technical problems or qu...

Page 5: ...2005 The product may not be disposed of in normal household waste The X on the trash can indicates the necessity of disposing of this product separately The device contains a built in rechargeable lit...

Page 6: ...Do not wind the power adapter cord tightly nor pull it over sharp edges and never crush or kink it If the power adapter cord is damaged please contact our Service Center to have it replaced Never try...

Page 7: ...s The Filling Chamber is made of metal do not touch it when it is hot The Dosing Capsule is made of metal do not touch it when it is hot Before cleaning disconnect the power adapter from the socket Th...

Page 8: ...ychotropic mind altering effect Thus there is a potential for abuse which governments in nearly all coun tries of the world counteract with cor responding laws Use only medicinal hemp flowers cannabis...

Page 9: ...e Keep the Instructions for Use for future ref erence Remove the MIGHTY MEDIC Vapor izer and the accessories from the box Immediately after unpacking check whether the Vaporizer the accesso ries the p...

Page 10: ...e frame and all six fields are visible The number of status fields visible depends on the extent of the battery charge Check the housings of the MIGHTY MEDIC Vaporizer and the power adapter for signs...

Page 11: ...on If the basic temperature can no longer provide adequate evaporation the booster temperature can be activated by means of a double click on the or ange colored ON OFF switch Once the booster tempera...

Page 12: ...ules by the nursing staff Inserting the Dosing Capsules into the MIGHTY MEDIC Vaporizer is con siderably easier than filling the Filling Chamber with ground hemp flowers 6 1 Filling the Dosing Capsule...

Page 13: ...or any other cannabis that has not been sub jected to recognised quality controls The amount of active ingredients in these products is generally unknown may fluctuate considerably and they often cont...

Page 14: ...the MIGHTY MEDIC Vapor izer has reached the set temperature 180 C 356 F set and actual tem peratures are the same also signaled by a short double vibration and the Mouthpiece with Lip Piece is folded...

Page 15: ...be used 8 HYGIENE Material Resistance of the MIGHTY MEDIC Vaporizer Please ensure that the Lip Piece the Cooling Unit with Mouthpiece and the MIGHTY MEDIC Vaporizer do not come in contact with the fol...

Page 16: ...or brittle Lip Pieces are not to be used 8 2 Cooling Unit with Mouthpiece When the vapors are cooled it is in evitable that a fraction is condensed on the internal surfaces of the Cool ing Unit The co...

Page 17: ...iece more frequently As an alternative to warm water with wash up liquid all parts of the Cool ing unit with Mouthpiece exception Cap Lock can be cleaned with etha nol Manual cleaning of the disassemb...

Page 18: ...h the upper Screen downwards out of the Filling Chamber Cap from above by using the Filling Chamber Tool supplied Reassemble in reverse order When assembling make sure that Seal Rings are properly sea...

Page 19: ...alified persons In Case of Problems If the power adapter has been in use unplug it at the socket and ensure that no one can connect the MIGHTY MEDIC Vaporizer to the mains supply again without this be...

Page 20: ...o be documented If the device is not functioning prop erly or fails any of the above tests the device has to be repaired 10 4 Technical Specifications Power adapter Manufacturer Mean Well types GSM36E...

Page 21: ...on on Electromagnetic Compatibility Immunity test IEC 60601 test level Compliance level Electromagnetic envi ronment guidance Guidance and Manufacturer s Declaration Electromagnetic Immu nity The MIGH...

Page 22: ...test level 10 THE MIGHTY MEDIC VAPORIZER Immunity test IEC 60601 test level Compliance level Electromagnetic envi ronment guidance Guidance and Manufacturer s Declaration Electromagnetic Immu nity The...

Page 23: ...con sidered If the measured field strength in the location in which the MIGHTY MEDIC Vaporizer is used exceeds the applicable RF compliance level above the MIGHTY MEDIC Vaporizer should be observed t...

Page 24: ...regular mesh width REF 03 11 MM MIGHTY MEDIC Normal Screen Set 6 pcs Lower Screen with regular mesh width REF 03 12 MM MIGHTY MEDIC Coarse Screen Set 6 pcs Upper Screen with coarse mesh width REF 04 0...

Page 25: ...users Normal wear or tear to the products is not con sidered a defect under warranty law If the customer has commissioned third parties with completing maintenance or repair of the product or if the c...

Page 26: ...imated costs and obtained cus tomer approval Copyright This document is copyright protected and may not be used either in whole or in part pursuant to Sections 15 et seqq UrhG German Copyright Act wit...

Page 27: ...AL 30 210 ENG 08 2017 Subject to alterations All rights reserved Manufacturer and Distributor STORZ BICKEL GMBH CO KG In Gruben cker 5 9 78532 Tuttlingen Germany Phone 49 7461 969707 0 Fax 49 7461 969...

Reviews: