2.2.6 LED 

PWR LED: If the light is on, the system is successfully started; If the light is off, 

the system is turned off.

 

ERR LED: User can define by themselves. 

SS LED: User can define by themselves. 

TX LED: If R1 sends data, TX1 flashes; if R2 sends data, TX2 flashes. 

RX LED: If R1 receives data, RX1 flashes; if R2 receives data, RX2 flashes. 

Figure 2-11 LED 

 

 

 

 

 

 

2.2.7 Debug 

CONN, Pin header,1 x 4 x 2.0, TH. User can view the debug message and use 

keyboard  to  input  debug  command.  It

’s TTL level, so we need a Uart-debug 

board when we use it. 

Figure 2-12 Debug board 

 

 

 

Table 2-7 Pin description of debug board 

Pin 

Description 

3.3V 

Pin 1 

Summary of Contents for FPC-N64

Page 1: ...FPC N64 User Manual M2M Gateway Product Version 1 0 Date 2019 11 02 For any question please contact Chengdu Vantron Technology Ltd Copyright Vantron Technology Ltd All rights reserved ...

Page 2: ...History This document describes FPC N64 briefly and is intended for all readers This table describes the version and release date No Version Description Date Author 1 V1 0 First release 2019 11 02 Guomin Zhang ...

Page 3: ...rks in this manual are properties of their respective owners No part of this manual may be copied reproduced translated or sold No changes or other purposes are permitted without the prior written consent of Vantron Vantron reserves the right of all publicly released copies of this manual Symbol Conventions The symbols that may be found in this document are defined as follows Symbol Type Descripti...

Page 4: ...r Safety Instructions Keep and comply with all operation instructions warnings and information Pay attention to warnings on this device Read the following precautions so as to decrease the danger of injury electric shock fire or any damage to the device Operations and service instructions are provided with the equipment Unit shall be used with indoor use antenna only No antenna for this unit can b...

Page 5: ...ource This product still contains a button lithium battery as a real time clock after its external power source is removed and therefore should not be short circuited during transportation or placed under high temperature Place cables properly Do not place cables at any place with extrusion danger Cleaning Instructions Please power off before cleaning the device Do not use spray detergent Clean wi...

Page 6: ...s 3 2 1 Product Appearance 3 2 2 Interface Description 4 2 2 1 Power Interface 4 2 2 2 Ethernet Interface 4 2 2 3 RS232 or RS485 Connector 5 2 2 4 RS485 Connector 6 2 2 5 Boot Configuration 7 2 2 6 LED 8 2 2 7 Debug 8 2 2 8 Renew Button 9 2 2 9 SD MMC Socket 9 3 Tips 10 Appendix A How to Contact Us 15 ...

Page 7: ... the embedded devices equipped with the state of the art technology and the best product services Vantron s M2M products are based on the most advanced ARM and Intel Atom processors and have low power consumption and high integration The products are designed for applications of M2M in industry finance retailing vehicle transportation etc ...

Page 8: ...T2 RXD and TXD 2 x LED for UART4 RXD and TXD 1 x LED for power 1 x LED for state of error 1 x LED for state of SS RTC Supported separately RTC chip power for super capacitor Control Button of Restored to Default setting GPIO 4 x GPIO Optional Software OS Linux Applications Provide SDK Power Input Wide Range 9 30V DC or 24V AC 3 x 3 81 mm Black Terminal Mechanical Dimensions 155 x 105 x 50 mm Box I...

Page 9: ...FPC N64 User Manual 3 2 FPC N64 Hardware Instructions 2 1 Product Appearance Figure 2 1 Front view Figure 2 2 Side view right Figure 2 3 Side view left ...

Page 10: ... outlook Table 2 2 Pin description of power connector Pin Description 1 Power input range DC9 30V or AC24V L 2 DC Ground or AC24V N 3 Shell ground 2 2 2 Ethernet Interface Standard RJ45 interface supporting 100M Full Half Duplex is a standard RJ45 Ethernet port Figure 2 5 Ethernet interface Pin 1 ...

Page 11: ...tor Standard vertical 1 x 3 x 3 81 mm male Terminal Block Figure 2 6 RS232 or RS485 connector Table 2 3 Pin description of RS232 or RS485 connector Pin Description Remarks 1 TX or RS485_A IO 2 RX or RS485_B IO 3 GND Figure 2 7 DIP Switch for selection ...

Page 12: ...ave pulled up a resistor of 510 ohm OFF No Bias 3 ON Have pulled down a resistor of 510 ohm OFF No Bias 4 ON Select RS232 OFF Select RS485 Select RS232 or RS485 2 2 4 RS485 Connector Standard vertical 1 x 3 x 3 81 mm male Terminal Block Figure 2 8 RS485 connector Table 2 5 Pin description of RS485 connector Pin Description Remarks 1 RS485_A IO 2 RS485_B IO 3 GND ...

Page 13: ...t Description Single 1 ON Have matched with a resistor of 120 ohm OFF No Term 2 ON Have pulled up a resistor of 510 ohm OFF No Bias 3 ON Have pulled down a resistor of 510 ohm OFF No Bias 2 2 5 Boot Configuration Figure 2 10 Boot configuration SHORT Boot from NAND OPEN Boot from SD MMC Boot Configurati on ...

Page 14: ... LED If R1 sends data TX1 flashes if R2 sends data TX2 flashes RX LED If R1 receives data RX1 flashes if R2 receives data RX2 flashes Figure 2 11 LED 2 2 7 Debug CONN Pin header 1 x 4 x 2 0 TH User can view the debug message and use keyboard to input debug command It s TTL level so we need a Uart debug board when we use it Figure 2 12 Debug board Table 2 7 Pin description of debug board Pin Descri...

Page 15: ...enew Button Renew button Press and hold this button to restore factory settings and the press time is user defined Figure 2 13 Renew button 2 2 9 SD MMC Socket This is standard SD card socket where user can save data on this storage Figure 2 14 SD MMC socket ...

Page 16: ...y with the following safety tips Do not use in combustible and explosive environment Keep away from combustible and explosive environment for fear of danger Keep away from all energized circuits Operators should not remove enclosure from the device Only the group or person with factory certification is permitted to open the enclosure to adjust and replace the structure and components of the device...

Page 17: ...ration of Conformity M2M Gateway FPC N64 This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Vantron Technology Inc 440 Boulder Court Suite 300 Pleasanton CA 94566 USA 925 621 8758 Décl...

Page 18: ... circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Réorienter ou déplacer l antenne de réception Augmenter la séparation entre l équipement et le récepteur Connectez l équipement dans une prise sur un circuit différent de celui auquel le récepteur est connecté Consultez le concessionnaire ou un technicien expérimenté en...

Page 19: ...age 2 L appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement Warning This class B digital apparatus complies with Canadian ICES 003 Industry Canada ICES 003 Compliance Label CAN ICES 3 B NMB 3 B Avertissement Cet appareil numérique de classe B est conforme à l ICES 003 canadien Industrie Canada ICES 003 Étiquette de c...

Page 20: ...fournir une distance de séparation d au moins 20 cm de toutes les personnes et ne doit pas être co localisée ou exploitée en conjonction avec toute autre antenne ou émetteur Les utilisateurs finaux et les installateurs doivent recevoir des instructions d installation d antenne et des conditions de fonctionnement des émetteurs pour satisfaire à la conformité à l exposition rf ...

Page 21: ...t us US Office Vantron Technology Inc Address 440 Boulder Court Suite 300 Pleasanton CA 94566 USA Tel 925 621 8758 Email sales vantrontech com China Office Chengdu Vantron Technology Ltd Address 6th Floor 1st Building No 9 3rd Wu Ke East Street Wu Hou District Chengdu 610045 China Tel 86 28 8512 3930 3931 8515 7572 6320 Email sales vantrontech com cn ...

Reviews: