VTGACF60IOM / 060507
Copyright 2007
Document Version 01
AllChem Performance Products, LP
Page 1: ...Installation and Operation Manual ACF 18 Automatic Chlorinating Feeder...
Page 2: ......
Page 3: ...ter P2002202 In Line Strainer P2002203 25 of 5 8 OD Tubing P2002225 Feeder Discharge Assembly discharge valve body discharge fitting and locking bolt P601204 Chlorine Feed Assembly sieve plate legs an...
Page 4: ...er Discharge Assembly 3 Discharge Fitting 4 Float Valve Body 5 Float Assembly 6 Chemical Feed Solenoid Valve 7 Supply Manifold 8 Inlet Water Solenoid Valve 9 Rinse Nozzle 10 Level Switch Assembly 11 C...
Page 5: ...n inlet pressure of 10 45 psi The flow rate will be con trolled in the range of 1 0 to 1 5 gpm CONNECTING THE ACF 18 RECOMMENDED INSTALLATION METHODS SIDESTREAM WITH BOOSTER PUMP AND VENTURI see Figur...
Page 6: ...p but before the filter while the sidestream effluent is returned after the heater The sidestream flow and venturi must be selected to remove a minimum of 1 5 gpm from the feeder at all times When usi...
Page 7: ...ned directly into the surge pit or vacuum filter pit Erratic controller readings can occur if chlorine is injected into the system prior to the sample line Heater corrosion or scaling can occur if the...
Page 8: ...lves Pool Return Venturi w check valve Inlet Ball Valve Flow Meter Strainer 1 2 Feeder Inlet Flow Control Valve optional H EATER if present P OOL P UMP B OOSTER P UMP F ILTER denotes PVC piping denote...
Page 9: ...er Flow From Pool Isolation Valves Pool Return Venturi w check valve Inlet Ball Valve Flow Meter Strainer Flow Control Valve optional H EATER if present P OOL P UMP F ILTER denotes PVC piping denotes...
Page 10: ...ion tank using the bolt located on the float valve arm For detailed instructions on adjusting the float contact your Vantage Representative 6 Prior to filling feeder read First Aid Precautionary State...
Page 11: ...der parts with fresh water The float assembly and other parts can be damaged with rough handling Use caution when cleaning these parts 4 When all parts have been cleaned the interior of the tubing ven...
Page 12: ...alves to prevent water flow into the feeder Do not reopen valves for at least 2 hours following application of shock or superchlorinating product to prevent contamination of tablets WINTERIZATION OF F...
Page 13: ...eration Manual Should the warranted equipment prove defec tive in workmanship or material the consumer s sole remedy shall be replacement of defective parts as is herein above expressly provided and u...
Page 14: ...VTGACF60IOM 060507 Copyright 2007 Document Version 01 AllChem Performance Products LP...