Maintenance

Due to the fan’s natural movement, connections may get loose after period of usage. To

ensure a proper and safety usage, it is highly recommended to inspect and tighten all 

connections every 6 months.

Cleaning

Cleaning your fan periodically will prolong its new appearance. Basic cleaning procedures

are as follows :

1. Use only water and mild soap. Do not use solvents, corrosive or acidic solution.

2. Damp the cloth lightly. Use only soft or lint-free cloth to clean the fan. Rough fabric will

    scratch the surface.

3. Do not bent the blades while cleaning. At the event where blades are bent or damage,

    order new set of blades from service center or dealer shop.

4. There is no need to oil the fan. 

Technical Specifications

Technical Specifications

Customer Service Centre

If you need any technical assistance or faulty report, please contact our customer 

service centre at :

Alpha Home Appliances Sdn. Bhd. 

(390258-H)

Head Office

 :  6, Jalan Sungai Kayu Ara 32/37, Berjaya Park, Section 32, 40460 Shah 

     

  Alam, Selangor.

Tel    

:  03-5740 6666 

Fax  :  03-5740 8220

Website 

:  www.alphamalaysia.com 

Email  :  [email protected]

Johor

 

:  71, Jalan Molek 3/10, Taman Molek, 81100 Johor Bahru.

Tel    

:  07-353 4833 / 4933 

Fax  :  07-355 4233

Melaka

 : 

19, 19-1 & 19-2, Jalan KSB 11, Taman Kota Syahbandar, 75200 Melaka.

Tel    

:  06-292 6292 / 6293 

Fax  :  06-292 6296

Perak

 

:  16, Jalan Tasek Timur, Taman Tasek Indra, 31400 Ipoh, Perak.

Tel 

:  05-545 2282 / 547 2282 Fax  : 05-547 6282

Penang

 

:  28, Jalan Icon City, Icon City, 14000 Bukit Mentajam, Penang.

Tel    

:  04-506 2366 / 2066 / 2566  Fax : 

04-506 2966

Pahang

 

:  A131, TK1, Jalan Wang Ah Jang, Taman Liza, 25100 Kuantan, Pahang.

Tel    

:  09-516 5226             

Fax  :   09-513 9226

Model
No. of Blades
Fan Width
Motor R.P.M
Voltage
Motor Wattage
Nett Weight

VC2-3B/52

3

52”

90 - 214

5W - 40W

5.6kg

220V-240V~ 50Hz

More than 1m

More than 2.5m (8’

 2”)

1320mm (4’ 4”)

290mm (1’)

350mm (1’

 2”)

Summary of Contents for VC2-3B/52

Page 1: ...INSTRUCTION MANUAL CEILING FAN MODEL VC2 3B 52 Version 2020 V1 ...

Page 2: ... leaving the fan remain earthed to prevent electrocution Tighten the blade firmly using a screw driver Blades that are detached from the unit during operation will cause serious injuries and property damages This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given superv...

Page 3: ...urfaces are potential locations which may cause injury hazards Avoid from being in contact with these places Before turning off the power supply set the remote controller s ON OFF switch to the OFF position If this is not done the unit s fans will start turning automatically when power resumes posing a hazard to service personnel or the user Do not operate any heating apparatus too close to the ce...

Page 4: ...ubber Pulley onto the ceiling hook and fix back the Bolt Clevis Nut and Washer IMPORTANT Clevis Pin MUST be insert to prevent nut from loosening Installation Instruction IMPORTANT DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO DIMMER SWITCH OR REGULATOR 5 Installation Instruction Rubber Pulley Bolt Clevis Pin Washer Nut Step 3 Remove the Safety Wire screw and spring washer from the Downrod Step...

Page 5: ...e wires from the receiver to House s Supply Wire Connect Earth Wire to House Supply Earth Terminal House Supply Wires Brown L Blue N Green Yellow E Green Yellow E Step 7 Install the Blades on Motor with Screw Install the Switch Housing by twisting in IMPORTANT Assemble the Fan Blades only after the ceiling fan is mounted on the hook Blade Screw Switch Housing Blade Green Yellow E Brown L Blue N Wh...

Page 6: ... SWITCH OR REGULATOR Circuit Diagram 9 Regulator Dimmer Switch DC Motor ANT W N Blue Grey Yellow White Neutral Blue Live Brown Earth Green Yellow Earth Green Yellow Brown Green Yellow MAIN PCB L E V U Power Supply 220V 240V 50Hz 220V 240V 50Hz Single Pole Switch Double Pole Switch Power Supply ...

Page 7: ... function works best at low speed Suitable for air conditioned condition Mount the remote control holder on the wall with the screws provided OFF 1 6 1H 3H 6H Turn off fan Fan speed lowest to highest Natural wind creating gentle sea breeze effect Forward Reverse turn anti clockwise or clockwise rotation Timer on fan turns on after 1hr Timer on fan turns on after 3hr Timer on fan turns on after 6hr...

Page 8: ...nical assistance or faulty report please contact our customer service centre at Alpha Home Appliances Sdn Bhd 390258 H Head Office 6 Jalan Sungai Kayu Ara 32 37 Berjaya Park Section 32 40460 Shah Alam Selangor Tel 03 5740 6666 Fax 03 5740 8220 Website www alphamalaysia com Email info alphamalaysia com Johor 71 Jalan Molek 3 10 Taman Molek 81100 Johor Bahru Tel 07 353 4833 4933 Fax 07 355 4233 Mela...

Reviews: