background image

 

Safety Precaution

2

STOP using the ceiling fan when any abnormality or failure occurs.

If unusual oscillating movement is observed, immediately stop using the ceiling fan and 

contact the manufacturer, its service agent or suitably qualified persons. 

CAUTION

Please take note of the following important points when installing.

The fixing means for attachment to the ceiling such as hooks or other devices shall be 

fixed with a sufficient strength to withstand 4 times the weight of the ceiling fan. 

The mounting of the suspension system shall be performed by the manufacturer, its 

service agent or suitably qualified persons. 
The fan is to be installed so that the blades are more than 2.5m above the floor.

 

Safety cord should not be longer than the earthing conductor. 

Should failure of the suspension system occur, the supporting of the fan must not rely on 

the earthing conductor. The earthing terminal in the fan assembly should be such that 

should any part of the suspension system fall off, the body of the fan assembly shall 

effectively earthed.

Ensure that the unit’s panel is closed after service or installation.

Unsecured panels will cause the unit to operate noisily.

Sharp edges and coil surfaces are potential locations which may cause injury 

hazards. Avoid from being in contact with these places.
Before turning off the power supply set the remote controller’s ON/OFF switch to 

the “OFF” position.

If this is not done, the unit’s fans will start turning automatically when power resumes, 

posing a hazard to service personnel or the user.

Do not operate any heating apparatus too close to the ceiling fan unit or use in room 

where mineral oil, oil vapour or oil steam exist, this may cause plastic part to melt or 

deform as a result of excessive heat or chemical reaction.

Ensure the colour of wires of the outdoor unit and the terminal markings are same to the 

indoors respectively.
Don’t use joined and twisted wires for incoming power supply.

Do not place any object in the path of the blades. Avoid raising objects or your arms near 

the ceiling fan.
The fan suspension system and blade screw tightening shall be examined yearly.

 

Replacement of parts of the safety suspension system device shall be performed by the 

manufacturer, its service agent or suitably qualified persons.

Torque value for screw/bolts for securing primary suspension system for motor is 2Nm.

3

Parts & Accessories

Motor Assembly with Downrod

Switch

Housing

Blade

Screw x 7

AAA

AAA

Battery x 2

Wall Screw x 2

Transmitter &

Holder x 1

3H

1H

6H

1

2

3

4

6

5

OFF

Blade x 3

Canopy

Coupling Cover

Rubber Pulley Assembly

Receiver

Summary of Contents for VC2-3B/52

Page 1: ...INSTRUCTION MANUAL CEILING FAN MODEL VC2 3B 52 Version 2020 V1 ...

Page 2: ... leaving the fan remain earthed to prevent electrocution Tighten the blade firmly using a screw driver Blades that are detached from the unit during operation will cause serious injuries and property damages This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given superv...

Page 3: ...urfaces are potential locations which may cause injury hazards Avoid from being in contact with these places Before turning off the power supply set the remote controller s ON OFF switch to the OFF position If this is not done the unit s fans will start turning automatically when power resumes posing a hazard to service personnel or the user Do not operate any heating apparatus too close to the ce...

Page 4: ...ubber Pulley onto the ceiling hook and fix back the Bolt Clevis Nut and Washer IMPORTANT Clevis Pin MUST be insert to prevent nut from loosening Installation Instruction IMPORTANT DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO DIMMER SWITCH OR REGULATOR 5 Installation Instruction Rubber Pulley Bolt Clevis Pin Washer Nut Step 3 Remove the Safety Wire screw and spring washer from the Downrod Step...

Page 5: ...e wires from the receiver to House s Supply Wire Connect Earth Wire to House Supply Earth Terminal House Supply Wires Brown L Blue N Green Yellow E Green Yellow E Step 7 Install the Blades on Motor with Screw Install the Switch Housing by twisting in IMPORTANT Assemble the Fan Blades only after the ceiling fan is mounted on the hook Blade Screw Switch Housing Blade Green Yellow E Brown L Blue N Wh...

Page 6: ... SWITCH OR REGULATOR Circuit Diagram 9 Regulator Dimmer Switch DC Motor ANT W N Blue Grey Yellow White Neutral Blue Live Brown Earth Green Yellow Earth Green Yellow Brown Green Yellow MAIN PCB L E V U Power Supply 220V 240V 50Hz 220V 240V 50Hz Single Pole Switch Double Pole Switch Power Supply ...

Page 7: ... function works best at low speed Suitable for air conditioned condition Mount the remote control holder on the wall with the screws provided OFF 1 6 1H 3H 6H Turn off fan Fan speed lowest to highest Natural wind creating gentle sea breeze effect Forward Reverse turn anti clockwise or clockwise rotation Timer on fan turns on after 1hr Timer on fan turns on after 3hr Timer on fan turns on after 6hr...

Page 8: ...nical assistance or faulty report please contact our customer service centre at Alpha Home Appliances Sdn Bhd 390258 H Head Office 6 Jalan Sungai Kayu Ara 32 37 Berjaya Park Section 32 40460 Shah Alam Selangor Tel 03 5740 6666 Fax 03 5740 8220 Website www alphamalaysia com Email info alphamalaysia com Johor 71 Jalan Molek 3 10 Taman Molek 81100 Johor Bahru Tel 07 353 4833 4933 Fax 07 355 4233 Mela...

Reviews: