Safety Precaution

2

STOP using the ceiling fan when any abnormality or failure occurs.

If unusual oscillating movement is observed, immediately stop using the ceiling fan and 

contact the manufacturer, its service agent or suitably qualified persons. 

CAUTION

Please take note of the following important points when installing.

The fixing means for attachment to the ceiling such as hooks or other devices shall be 

fixed with a sufficient strength to withstand 4 times the weight of the ceiling fan. 
The mounting of the suspension system shall be performed by the manufacturer, its 

service agent or suitably qualified persons. 
The fan is to be installed so that the blades are more than 2.5m above the floor.

 

Safety cord should not be longer than the earthing conductor. 

Should failure of the suspension system occur, the supporting of the fan must not rely on 

the earthing conductor. The earthing terminal in the fan assembly should be such that 

should any part of the suspension system fall off, the body of the fan assembly shall 

effectively earthed.

Ensure that the unit’s panel is closed after service or installation.

Unsecured panels will cause the unit to operate noisily.

Sharp edges and coil surfaces are potential locations which may cause injury 

hazards. Avoid from being in contact with these places.
Before turning off the power supply set the remote controller’s ON/OFF switch to 

the “OFF” position.

If this is not done, the unit’s fans will start turning automatically when power resumes, 

posing a hazard to service personnel or the user.
Do not operate any heating apparatus too close to the ceiling fan unit or use in room 

where mineral oil, oil vapour or oil steam exist, this may cause plastic part to melt or 

deform as a result of excessive heat or chemical reaction.
Ensure the colour of wires of the outdoor unit and the terminal markings are same to the 

indoors respectively.
Don’t use joined and twisted wires for incoming power supply.
Do not place any object in the path of the blades. Avoid raising objects or your arms near 

the ceiling fan.
The fan suspension system and blade screw tightening shall be examined yearly.

 

Replacement of parts of the safety suspension system device shall be performed by the 

manufacturer, its service agent or suitably qualified persons.

Torque value for screw/bolts for securing primary suspension system for motor is 2Nm.

33

Parts & Accessories

Wall Screw x 2

Transmitter & Holder

AA

AA

A

A

AAA Battery x 2

Blade x 5

Receiver

Canopy & Coupling Cover

Downrod

Rubber Pulley Assembly

Blade Screw & Washer x 11

Motor Assembly

Summary of Contents for i6-5B/40

Page 1: ...INSTRUCTION MANUAL CEILING FAN MODEL i6 5B 40 i6 5B 56 Version 2022 V1...

Page 2: ...leaving the fan remain earthed to prevent electrocution Tighten the blade firmly using a screw driver Blades that are detached from the unit during operation will cause serious injuries and property d...

Page 3: ...dges and coil surfaces are potential locations which may cause injury hazards Avoid from being in contact with these places Before turning off the power supply set the remote controller s ON OFF switc...

Page 4: ...cover and the canopy through the downrod Step 2 Remove the Bolt Clevis Nut Washer and Rubber Pulley from the Downrod Place the Rubber Pulley onto the ceiling hook and fix back the Bolt Clevis Nut and...

Page 5: ...Wire with spring washer onto the Downrod 7 Below shows a complete installation diagram Step 7 Install the Blades on Motor with Blade Screw Install the Switch Housing by twisting in IMPORTANT Assemble...

Page 6: ...DIMMER SWITCH OR REGULATOR Circuit Diagram 9 Double Pole Switch Single Pole Switch 220V 240V 50Hz DC Motor ANT W N Blue Red Grey Pink Neutral Blue Live Brown Earth Green Yellow Earth Green Yellow Bro...

Page 7: ...ng in memory and the next time you turn on the fan fan will operate as the last setting Function of Forward Reverse Fan must be turned on and rotating Press Forward Reverse button and fan will slow do...

Page 8: ...to the fan s natural movement connections may get loose after period of usage To ensure a proper and safety usage it is highly recommended to inspect and tighten all connections every 6 months Cleani...