background image

Safety Precaution

Table of Contents

Warning

Installation and maintenance work shall only be performed by qualified persons, familiar 

with local code and regulation, and experienced with this type of appliance.
All field wiring must be installed in accordance with the national wiring regulation.
Ensure that the rated voltage of the unit corresponds to that of the name plate before 

commencing wiring work according to the wiring diagram.

The appliance must be permanently connected to the electricity supply through a double

pole switch having a contact separation of at least 3mm in all poles.

The unit must be GROUNDED to prevent possible hazard due to insulation failure.

The earth wire is approximately 60mm longer than safety wire. This is to ensure at the 

event whereby the suspension system fails, the (L) and (N) wire will break leaving the 

fan remain earthed to prevent electrocution.

Tighten the blade firmly using a screw driver.

Blades that are detached from the unit during operation will cause serious injuries and 

property damages.

This appliance is not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless 

they have been given supervision or instruction concerning use of the appliance by a 

person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliances.
Confirm that the power supply has been switched OFF before installing or servicing the 

unit. Ensure that the blade is fully static before doing any maintenance work.

Item

1. Safety Precaution
2. Parts & Accessories
3. Installation Instruction
4. Power Supply Connection
5. Circuit Diagram
6. Transmitter Learning Process
7. Transmitter Function & Assembly
8.  Maintenance
9. Technical Specifications
10. Customer Service Centre

Page No.

1 - 2
3
4 - 7
8
9
10
11
12
12 - 13
13

Summary of Contents for i6-5B/40

Page 1: ...INSTRUCTION MANUAL CEILING FAN MODEL i6 5B 40 i6 5B 56 Version 2022 V1...

Page 2: ...leaving the fan remain earthed to prevent electrocution Tighten the blade firmly using a screw driver Blades that are detached from the unit during operation will cause serious injuries and property d...

Page 3: ...dges and coil surfaces are potential locations which may cause injury hazards Avoid from being in contact with these places Before turning off the power supply set the remote controller s ON OFF switc...

Page 4: ...cover and the canopy through the downrod Step 2 Remove the Bolt Clevis Nut Washer and Rubber Pulley from the Downrod Place the Rubber Pulley onto the ceiling hook and fix back the Bolt Clevis Nut and...

Page 5: ...Wire with spring washer onto the Downrod 7 Below shows a complete installation diagram Step 7 Install the Blades on Motor with Blade Screw Install the Switch Housing by twisting in IMPORTANT Assemble...

Page 6: ...DIMMER SWITCH OR REGULATOR Circuit Diagram 9 Double Pole Switch Single Pole Switch 220V 240V 50Hz DC Motor ANT W N Blue Red Grey Pink Neutral Blue Live Brown Earth Green Yellow Earth Green Yellow Bro...

Page 7: ...ng in memory and the next time you turn on the fan fan will operate as the last setting Function of Forward Reverse Fan must be turned on and rotating Press Forward Reverse button and fan will slow do...

Page 8: ...to the fan s natural movement connections may get loose after period of usage To ensure a proper and safety usage it is highly recommended to inspect and tighten all connections every 6 months Cleani...