9.  Regulate air pressure by turning the air regulator knob.  Unlock by pulling up the knob then 

turn. Pressure reading will indicate pressure. DO NOT adjust above 100 psi (7 BARS).

10. To engage the ESD air flow, turn the valve on the rear of the unit for 

the ESD air supply.  Any time full ESD protection is required, this valve 

must be on.  The gauge should read roughly 30 psi before depressing 

foot pedal and can be changed by removing the tamper-resistant 

knob.  This can be adjusted to increase flow by removing the snap-ring on the regulator knob, 

adjusting, and replacing the snap ring.

11. Turn the red power switch on the ESD power supply on, it will light when connected correctly.  

Both the power supply and the blaster's light cord must be connected to a properly grounded 

wall plug or cable.

12. To begin blasting, use the foot pedal to start the flow of air and blasting media.  Release the 

foot pedal to stop the flow.

13. A dust collector is strongly recommended to contain the dust inside the cabinet:

-120V Abrasive-Vac Dust Collector 

 P/N 10660

-220V Abrasive-Vac Dust Collector  

P/N 10664

MAINTENANCE

Vaniman blasters are designed to be low maintenance. However, as the materials used in a 

microblaster are abrasive by design, components do wear out. A few minor areas should be 

maintained regularly for a long product life.

Handpieces Hoses: 

Check handpiece hoses for wear regularly. When hose feels thin or holes develop, the tubing 

should be replaced. 
On the rear of IO/Master units, there is a pinch valve that controls the flow of media by squeezing 

andreleasing the handpiece tube. This will be the point of highest wear on the tubing and 

therefore the hose should be moved periodically in order to wear a new section of hose. If a 

hole develops, replace the tubing.

Handpiece Tip Installation:

It is imperative that the handpiece tip and sealing o-ring be installed correctly and securely 

to avoid damage or leaks. Install in the manner shown in Illustration 1 and ensure the tip and 

o-ring sit evenly in the assembly.

Tanks:

When installing the lids on the tanks, be sure the lid is rid of any blasting material or debris. 

If the tank or lid begins to wear, replace immediately. Do not over-tighten the lid on the unit. 

The fittings on the bottom of the tank are designed for easy maintenance of the hoses. To 

remove a handpiece tubing from quick disconnect fitting, push toward the tank on the plastic 

ring while pulling the tubing out. Do not remove the hose fittings while tank is full of media 

and upright; turn the tank upside down or empty before removing hoses. To replace, be sure 

the fitting and hose are free of debris or abrasives and push the hose firmly into the fitting. Be 

sure the tube reaches beyond the black o-ring that is just above the quick disconnect fitting 

in the tank. Improper installation will result in leakage and damage to the tanks.

Summary of Contents for MASTER PROBLAST 3 ESD

Page 1: ...wer tool or BATTERY operated cordless power tool 1 Work area safety a Keep work area clean and well lit Cluttered or dark areas invite accidents b Do not operate power tools in explosive atmospheres s...

Page 2: ...ool on A wrench or a key left attached to a rotating part of the power tool may result in personal injury e Do not overreach Keep proper footing and balance at all times This enables better control of...

Page 3: ...lways disconnect the unit from the compressed air and power sources before beginning any maintenance Any abrasive material on the o ring may lead to leakage and early wear of the o ring After filling...

Page 4: ...manual and that the following label indicates that the user should reference this manual prior to operation 4 LIABILITY EXCLUSION Vaniman Manufacturing shall be absolved from all claims for damages a...

Page 5: ...blasting media in the micron size specified on tank label DO NOT OVERFILL clogging may result 6 Inspect lid for any cracks or areas that might create leaks Wipe off excess abrasive and screw lid secu...

Page 6: ...ew minor areas should be maintained regularly for a long product life Handpieces Hoses Check handpiece hoses for wear regularly When hose feels thin or holes develop the tubing should be replaced On t...

Page 7: ...blaster regulators include a filter for small amounts of oil and moisture If moisture causes the media to clump or cake in the tanks improper media flow will result Be sure the air supply is relative...

Page 8: ...e preparation 97925 Glass Bead 50 m Smoothing polishing Cleans and polishes without removing material Fig Description Reorder Part Number 1 ESD Regulator 2227 2 ESD Ionizer 3490 3 Pinch Valve 2234 4 V...

Page 9: ...fferson Ave Murrieta CA 92562 1 800 VANIMAN 826 4626 USA www vaniman com sales vaniman com MASTER PROBLAST3 ESD 08 23 Page 9 MASTER PROBLAST 3 ESD PLUMBING Foot Pedal Air Supply In ESD Regulator Power...

Page 10: ...plate to the outlet body Fig 1 but keep the outlet faceplate in place on the outlet once the screw is removed 2 Plug the power supply into the provided gray outlet adapter then plug both into one of t...

Reviews: