MASTER PROBLAST 3 ESD

PROPER GROUNDING PROCEDURE

When setting up your Vaniman ESD Blaster, it is important to correctly ground your system to provide 

the best posibible protection against ESD damage to the parts you are blasting. To properly ground your 

system, complete the following steps:

1.  Using a typical wall outlet, unscrew the middle screw that holds the outlet faceplate to the outlet 

body (Fig. 1), but keep the outlet faceplate in place on the outlet once the screw is removed.

2.  Plug the power supply into the provided gray outlet adapter, then plug both into one of the wall 

outlets so that the adapter's metal tab with a hole in it aligns with the outlet's faceplate mounting 

hole (Fig. 2). 

3.  Take the green wire attached to the power supply wiring harness with the ring terminal on the end 

and slide the ring terminal between the metal tab of the gray adapter and the outlet faceplate, with 

the holes aligned.

4.  Secure the adapter and power supply to the outlet faceplate using the same screw removed in step 

1 above. Your ESD system will now be properly grounded.

Fig. 1

Fig. 2

Summary of Contents for MASTER PROBLAST 3 ESD

Page 1: ...wer tool or BATTERY operated cordless power tool 1 Work area safety a Keep work area clean and well lit Cluttered or dark areas invite accidents b Do not operate power tools in explosive atmospheres s...

Page 2: ...ool on A wrench or a key left attached to a rotating part of the power tool may result in personal injury e Do not overreach Keep proper footing and balance at all times This enables better control of...

Page 3: ...lways disconnect the unit from the compressed air and power sources before beginning any maintenance Any abrasive material on the o ring may lead to leakage and early wear of the o ring After filling...

Page 4: ...manual and that the following label indicates that the user should reference this manual prior to operation 4 LIABILITY EXCLUSION Vaniman Manufacturing shall be absolved from all claims for damages a...

Page 5: ...blasting media in the micron size specified on tank label DO NOT OVERFILL clogging may result 6 Inspect lid for any cracks or areas that might create leaks Wipe off excess abrasive and screw lid secu...

Page 6: ...ew minor areas should be maintained regularly for a long product life Handpieces Hoses Check handpiece hoses for wear regularly When hose feels thin or holes develop the tubing should be replaced On t...

Page 7: ...blaster regulators include a filter for small amounts of oil and moisture If moisture causes the media to clump or cake in the tanks improper media flow will result Be sure the air supply is relative...

Page 8: ...e preparation 97925 Glass Bead 50 m Smoothing polishing Cleans and polishes without removing material Fig Description Reorder Part Number 1 ESD Regulator 2227 2 ESD Ionizer 3490 3 Pinch Valve 2234 4 V...

Page 9: ...fferson Ave Murrieta CA 92562 1 800 VANIMAN 826 4626 USA www vaniman com sales vaniman com MASTER PROBLAST3 ESD 08 23 Page 9 MASTER PROBLAST 3 ESD PLUMBING Foot Pedal Air Supply In ESD Regulator Power...

Page 10: ...plate to the outlet body Fig 1 but keep the outlet faceplate in place on the outlet once the screw is removed 2 Plug the power supply into the provided gray outlet adapter then plug both into one of t...

Reviews: