TROUBLESHOOTING

 WARNING: Turn off and un-

plug heater and let cool before
servicing. Only a qualified ser-
vice person should service and
repair heater.

REMEDY

1. Replace ignitor
2. Replace ignitor
3. Reconnect ignitor cable

4. Free ignitor cable if pinched by any

metal or tubing. Keep ignitor cable dry

5. Tighten nut holding piezo ignitor to

heater cabinet. Nut is located inside
heater cabinet at top

6. Replace ignitor cable
7. Replace piezo ignitor

1. Turn on gas supply or open equipment

shutoff valve

2. Turn control knob to PILOT position
3. Press in control knob while in PILOT

position

4. Continue holding down control knob.

Repeat igniting operation until air is re-
moved

5. Clean ODS/pilot (see Cleaning and

Maintenance, page 19) or replace ODS/
pilot assembly

6. Replace gas regulator

1. Press in control knob fully
2. After ODS/pilot lights, keep control

knob pressed in 30 seconds

3. Wait one minute for safety interlock sys-

tem to reset. Repeat ignition operation

4. Fully open equipment shutoff valve
5. Hand tighten until snug, then tighten 1/4

turn more

6. A) Contact local natural gas company

B) Clean ODS/pilot (see Cleaning and
Maintenance
, page 19) or replace ODS/
pilot assembly

7. Replace thermocouple
8. Replace control valve

POSSIBLE CAUSE

1. Ignitor electrode positioned wrong
2. Ignitor electrode broken
3. Ignitor electrode not connected to igni-

tor cable

4. Ignitor cable pinched or wet

5. Piezo ignitor nut is loose

6. Broken ignitor cable
7. Bad piezo ignitor

1. Gas supply turned off or equipment

shutoff valve closed

2. Control knob not in PILOT position
3. Control knob not pressed in while in

PILOT position

4. Air in gas lines when installed

5. ODS/pilot is clogged

6. Gas regulator setting is not correct

1. Control knob not fully pressed in
2. Control knob not pressed in long enough

3. Safety interlock system has been triggered

4. Equipment shutoff valve not fully open
5. Thermocouple connection loose at con-

trol valve

6. Pilot flame not touching thermocouple,

which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot

7. Thermocouple damaged
8. Control valve damaged

OBSERVED PROBLEM

When ignitor button is pressed, there is no
spark at ODS/pilot

When ignitor button is pressed, there is
spark at ODS/pilot but no ignition

ODS/pilot lights but flame goes out when
control knob is released

 CAUTION: Never use a wire,

needle, or similar object to clean
ODS/pilot. This can damage ODS/
pilot unit.

Note:

 For additional help, visit DESA

International’s technical service web site
at 

www.desatech.com

.

Note:

 All troubleshooting items are listed in

order of operation.

www.desatech.com

Summary of Contents for VMH3000TN

Page 1: ...er serviceagency orthe gas supplier WARNING Improper installa tion adjustment alteration service or maintenance can cause injury or property dam age Refer to this manual for correct installation and o...

Page 2: ...or other accessory not approvedforusewiththisheater 3 This heater shall not be installed in a bedroom or bathroom 4 This heater needs fresh outside air ven tilation to run properly This heater has an...

Page 3: ...kdi dko em kgo dki rlnf gpd fAS DF KIG LF JI als kdi dko em kgo dki rlnf gpd f AS DF KIG LF JI als kdi dko em kgo dki rlnf gpd fAS DF KIG LF JI als kdi dko em kgo dki rlnf gpd f AS DF KIG LF JI als k...

Page 4: ...heater cabinet Attach on top and sides with four brass screws included in hard ware package see Figure 7 9 Reattach front panel to heater if you are going to mount the heater to the base Do not reatt...

Page 5: ...ith open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to areas such as joints around window and door frames be tw...

Page 6: ...ances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr max...

Page 7: ...Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Figure 9 Ventilation Air from Outdoors AIR FOR COMBUSTION AND VENTILATION Continued WARNING Rework wo...

Page 8: ...ll heater Call dealer where you bought heater for proper type heater INSTALLATION ITEMS Beforeinstallingheater makesureyouhave the items listed below piping check local codes sealant resistant to prop...

Page 9: ...16 inches apart from their centers Attach mounting bracket to wall in one of two ways 1 Attaching to wall stud 2 Attaching to wall anchor Attaching To Wall Stud This method pro vides the strongest ho...

Page 10: ...screws until heater is firmly secured to wall Do not over tighten Note Do not replace front panel at this time Replace front panel after making gas connections and checking for leaks see pages 12 and...

Page 11: ...ife at marked locations before drilling If securing to a wood floor drill a 3 4 deep hole using a 1 8 diameter drill bit Do not use anchors in wood floors If securing to a concrete floor drill a 1 3 8...

Page 12: ...Check your local codes Use pipe of 1 2 or greater diameter to allow proper gas volume to heater If pipe is too small undue loss of pressure will occur Installation must include an equipment shutoff v...

Page 13: ...off valve see Fig ure 21 2 Pressurize supply piping system by either using compressed air or open ing main gas valve located on or near gas meter 3 Check all joints from gas meter to equipment shutoff...

Page 14: ...lot does not stay lit refer to Troubleshooting pages 16 through 18 Also contact a qualified service person or gas supplier for repairs Untilrepairsaremade lightpilotwith match To light pilot with matc...

Page 15: ...rect Pilot Flame Pattern Thermocouple Thermocouple INSPECTING BURNER Figure 26 Incorrect Pilot Flame Pattern Pilot Burner Pilot Burner Check pilot flame pattern and burner flame pattern often PILOT FL...

Page 16: ...ve POSSIBLE CAUSE 1 Ignitor electrode positioned wrong 2 Ignitor electrode broken 3 Ignitor electrode not connected to igni tor cable 4 Ignitor cable pinched or wet 5 Piezo ignitor nut is loose 6 Brok...

Page 17: ...ifice 1 Turn heater off when using furniture polish wax carpet cleaners or similar products TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS pilot is lit Delayed ignition of...

Page 18: ...IBLE CAUSE 1 Metal expanding while heating or con tracting while cooling 1 Heater burning vapors from paint hair spray glues etc see IMPORTANT statement above 2 Gas leak SeeWarning statement at top of...

Page 19: ...gas supplier SERVICE HINTS CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas This provides a clean burning flame...

Page 20: ...20 104431 NATURAL GAS RESIDENTIAL HEATERS 12 1 12 2 ILLUSTRATED PARTS BREAKDOWN VMH3000TN 1 2 9 10 10 11 12 13 14 15 17 19 20 23 24 25 8 6 6 21 7 1 3 5 16 18 4 22 26 1...

Page 21: ...12 099440 05 ODS Pilot Assembly 1 12 1 098514 01 Thermocouple 1 12 2 098594 01 Ignitor Electrode 1 13 103447 01 Burner 1 14 099387 03 3 16 Pilot Tubing 1 15 103845 09 Injector 1 16 NJF 8C Nut Hex 1 1...

Page 22: ...0 323 5190 You can also visit DESA International s technical service web site at www desatech com SPECIFICATIONS Btu Variable 15 000 30 000 Type Gas Natural Only Ignition Piezo Pressure Regulator Sett...

Page 23: ...in a walnut finish or an unfinished hardwood ready to stain or paint Complete assembly and installation instructions included EQUIPMENT SHUTOFF VALVE GA5010 Equipmentshutoffvalvewith1 8 NPTtap HEARTH...

Page 24: ...all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged a...

Reviews: