background image

18

®

B-VENT FREESTANDING FIREPLACE

105500

TO TURN OFF GAS

TO APPLIANCE

1.

Open lower louver panel.

2a. Set selector switch in the “OFF”

position.

2b.

If Using Optional Hand-Held Re-
mote:

 Set selector switch in the OFF

position to prevent draining battery.

3.

Turn off all electrical power to the
appliance if service is to be performed.

4.

Push in gas control knob slightly and
turn clockwise 

 to “OFF”.

5.

Close lower panel.

Shutting Off Burners Only (pilot
stays lit)

You may shut off the burners and keep
the pilot lit by doing one of the following:

1.

Turn control knob clockwise 
to the PILOT position.

2.

Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.

Remove glass door (see Removing/
Replacing Glass Door
, page 16).

2.

Follow steps 1 through 8 under Light-
ing Instructions
.

3.

Depress control knob and light pilot
with match.

4.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow steps 10 through 14, column 2.

5.

Replace glass door (see Removing/
Replacing Glass Door
, page 16).

OPERATING
FIREPLACE

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor's phone. Follow
the gas supplier's instructions.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don't try to repair it, call a
qualified service technician. Force or
attempted repair may result in a fire
or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

FOR YOUR SAFETY

READ BEFORE

LIGHTING

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information
in column one.

2.

Open lower panel.

3.

Turn ON/OFF switch to “OFF”.

4.

Turn off all electric power to the
fireplace.

5.

Push in gas control knob slightly and
turn clockwise 

 to “OFF”.

6.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation in column one. If you don't
smell gas, go to the next step.

7.

The pilot is located by the main
burner and should not require ac-
cessing for lighting.

8.

Turn knob on gas control counter-
clockwise 

 to “PILOT”.

9.

Push in control knob all the way and
hold. Immediately light the pilot by
repeatedly depressing the piezo
spark ignitor until a flame appears.
Continue to hold for about one (1)
minute after the pilot is lit. Release
knob and it will pop back. Pilot
should remain lit. If it goes out, re-
peat steps 5 through 8.
• If knob does not pop up when re-

leased, stop and immediately call your
service technician or gas supplier.

• If the pilot will not stay lit after sev-

eral tries, turn the gas control knob
to “OFF” and call your service
technician or gas supplier.

10. Turn gas control counterclockwise

 to “ON”.

11. Turn on all electric power to the

fireplace.

12. Turn the ON/OFF switch to ON

position.

13. This valve is equipped with a HI/LO

feature. Set fireplace input as desired.

14. Close lower panel.

Figure 45 - Control Valve

LO HI

OFF

ON

PI

LO

T

Gas Control
Knob

Variable
Control Knob

Piezo Ignitor

Summary of Contents for SBVBN(A)

Page 1: ...res Forassistance or additional information consultaqualifiedinstaller service agency or the gas supplier This appliance may be installed in an aftermarket manufactured mobile home where not prohibite...

Page 2: ...qualified service person with glass door properly seated and sealed gas leakage can occur Carbon Monoxide Poisoning Early signsofcarbonmonoxidepoisoningresemble theflu withheadaches dizziness ornause...

Page 3: ...d vents vertically Heat is gener ated by both realistic flames and glowing embers When used without the blower ac cessory the fireplace requires no electricity making it ideal for emergency backup hea...

Page 4: ...igure 4 on page 5 4 This stove is a freestanding unit de signed to set directly on the floor If your fireplace is to be installed directly on carpeting vinyl tile or any combus tible material other th...

Page 5: ...ing Down Stove On Side Figure 8 Removing Pallet Wood From The Bottom of The Stove Figure 6 Removing Back Panel Bolt Product Identification Label Back Stove Panel Pallet Wood Bolt Pallet Wood Bottom Of...

Page 6: ...p nut is a bolt stop and the bot tom nut is for door leveling adjustment 12 Check general catch bolt alignment with door claw Make final adjustment and door leveling after stove is in nor mal standing...

Page 7: ...jects in blower wheel Turn blower on and check for operation Turn blower off by rotating knob fully counterclock wise before continuing NOTICE If installing blower in an existing fireplace with gas c...

Page 8: ...nearby combustibles This appli ance is equipped with a safety control sys tem designed to protect against improper venting of combustion products It is very important that the venting system maintain...

Page 9: ...osure walls should have a fire rating equal to or greater than the floors through which the gas vent passes except in single or two family dwellings Situate the gas vent in the structure so that it ca...

Page 10: ...should be relined with appropriate listed relining systems Cleanout access may be required NOTICE Consult the authority having jurisdiction in your area regarding listed chimney liner venting applicat...

Page 11: ...c gas A simple spillage test can be con ducted if spillage is suspected See Checking Gas Connection pages 13 and 14 CAUSES OF SPILLAGE AND CORRECTIVE ACTION Incorrect Vent Sizing If the vent is too sm...

Page 12: ...ector if allowed by local codes not provided AnA G A design certifiedmanualshutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Pur chase the A G A design certified man...

Page 13: ...ation Items Needed 5 16 hex socket wrench or nut driver sealant resistant to propane LP gas not provided 1 Open lower door panel 2 Route flexible gas line provided by installer from manual shutoff val...

Page 14: ...Open propane LP supply tank valve for propane LP fireplace or main gas valve located on or near gas meter for natu ral gas fireplace 3 Make sure control knob of fireplace is in the OFF position 4 Chec...

Page 15: ...at sources such as lamps direct sun light fireplace or heat and air condi tioning ducts WARNING Do not connect this thermostat to a power source Electrical shock and or fire hazard will occur 5 Gently...

Page 16: ...s seeFigure35 5 Place receiver into valve bracket and align holes see Figure 36 6 Use push in fasteners included with receiver to secure to bracket 7 Connect the wires from the receiver to the valve a...

Page 17: ...Figure 41 Installing Log No 2 Figure 42 Installing Log No 3 Figure 43 Installing Log No 4 WARNING The glass door must be securely in place before running this fireplace Do not run this fireplace if g...

Page 18: ...turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or expl...

Page 19: ...on the hand held remote control unit Figure 47 Setting the GHRCT Selector Switch control Knob and Flame Adjustment Knob for Remote Operation TEMP STATUS HI LO MAN ON AUTO OFF Figure 48 Hand Held Ther...

Page 20: ...Blower controls are located on the left side of the switch bracket to the left just inside the louver panel Both the GA3700 manual blower and the DA3610T thermostatically controlled blower have an ON...

Page 21: ...e used when replacing broken ordamagedglassdoorpanel see ReplacementParts page25 This glass door panel is a complete unit No substitute materials may be used If glass has been broken carefully remove...

Page 22: ...pen 4 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor Nut is located behind the...

Page 23: ...from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 21 or replace burner orifice 1 Adjust the log set so that the flame does n...

Page 24: ...Control valve defective 1 Gas leak See Warning statement above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted o...

Page 25: ...ng controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Note Use only original replacement parts Thiswillprotectyourwarrantycoveragefor parts replac...

Page 26: ...Pressure 4 5 w c 11 0 w c Thermal Efficiency 70 70 Dimension Inches mm HxWxD Fireplace 27 x 26 x 25 27 x 26 x 25 685 8 x 660 4 x 635mm 685 8 x 660 4 x 635mm Carton Insert Only 23 x 33 x 23 23 x 33 x...

Page 27: ...ireplaces THERMOSTATICALLY CONTROLLED BLOWER KIT DA3610T Provides better heat distribution Blower turns off and on automatically as needed Completeinstallationandoperationinstruc tions included in thi...

Page 28: ...ENT FREESTANDING FIREPLACE 105500 ILLUSTRATED PARTS BREAKDOWN SBVBN A SBVBP A LO H I P I L O T OFF ON 24 17 18 19 21 23 1 23 4 23 2 23 3 26 27 4 22 9 4 1 10 11 8 2 4 4 7 28 13 14 15 16 20 20 25 5 29 3...

Page 29: ...urner Propane LP 1 18 104506 03 Orifice Natural 1 104506 04 Orifice Propane LP 1 19 104507 01 Brass Elbow 1 20 104508 01 Brass Fitting 2 21 105493 01 Aluminum Tubing Assy 1 22 105325 01 Air Deflector...

Page 30: ...repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXP...

Reviews: