OPERATING GUIDELINES AND MAINTENANCE
INSTRUCTIONS

GLASS DOORS

Only the cabinet type doors can be opened, the front glass panel
assembly is stationary and must be installed with doors.

When firebox is in operation, both sets of cabinet doors on each side
of firebox, must be in the FULLY OPEN or FULLY CLOSED
position only or a fire hazard may be created (see Figure 32).

Figure 33

DAMPER MECHANISM

The damper control lever is located inside the fire chamber (see
Figure 33). Make sure lever is cool before handling. Pull down to
CLOSE, push up to OPEN. The damper must be open when lighting
a fire; not doing so will cause smoke spillage into the room.

When the firebox is not in use, close the damper to prevent downdrafts
from entering room.

The damper mechanism should be per the following figure.

OUTSIDE AIR MECHANISM

The outside air handle is located at the right hand side of the firebox
rear refractor (Figure 33). Pull to close, push to open, Always open
the mechanism when starting a fire, this provides adequate outside
combustion air. Close the mechanism when not in use to prevent cold
air from entering the room.

Periodically check your outside air intake vent hood for any possible
obstructions (snow, bushes, etc.).

GRATE

The grate is designed to provide you with the maximum solid fuel
capacity, do not attempt to defeat its purpose, doing so may cause
smoke spillage and may cause a fire hazard.

Do not overload the grate or obstruct the required air space beneath
it. Always keep ashes from building up under the grate.

WARNING: RISK OF FIRE! REPLACE GRATE WITH
VANGUARD MODEL 36PNGR GRATE ONLY.

Never obstruct the flow of combustion and ventilation air.
Keep the front of the firebox clear of all obstacles and
materials.

WARNING: CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH SURFACE
TEMPERATURES AND TO STAY AWAY FROM THESE
TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SU-
PERVISED WHEN THEY ARE IN THE SAME ROOM AS
THE FIREBOX.

FOR FURTHER OPERATING GUIDELINES, INSTRUC-
TIONS AND WARRANTY INFORMATION PLEASE RE-
FER TO YOUR OWNER'S MANUAL OR CONTACT YOUR
AUTHORIZED DEALER.

CABINET DOORS MUST EITHER BE FULLY OPEN (AS SHOWN)
OR FULLY CLOSED WHEN FIREPLACE IS IN OPERATION

SIDE PANEL IS
STATIONARY

CABINET GLASS
DOOR (TYP. OF 4)

Figure 32

Summary of Contents for PENINSULA VPN36

Page 1: ...should be located out of traffic and away from furniture and draperies Do not place clothing or other flammable materials on or near the appliance NEVER leave children unattended when a fire is burni...

Page 2: ...MNEY PIPE INSTALLATION PG 7 9 FINISHING YOUR CHIMNEY SYSTEM PG 9 10 TERMINATIONS PG 11 11 FINISHING YOUR FIREBOX PG 12 12 OPERATING GUIDELINES AND MAINTENANCE INSTRUCTIONS PG 13 13 REPLACEMENT ACCESSO...

Page 3: ...or approved by DESA INTERNATIONAL in this wood burning firebox PROPER INSTALLATION is the most important step in ensur ing a safe and continuous operation of this firebox Although grounding may not b...

Page 4: ...uld not be placed within 9 inches of the effective opening of this firebox The effective opening is considered the opening where actual heat output may occur Combustible material above and projecting...

Page 5: ...opening except on the end where projection is 16 in min to the front and 20 in to the sides see Figure 10 page 6 1 2 MIN OVERLAP 1 2 MIN METAL SAFETY STRIPS SUPPLIED 1 2 MIN TO COMBUSTIBLES 2 MIN CLEA...

Page 6: ...the outside air kit please refer to the instructions included with the kit For operating instruc tions please refer to your owner s manual GAS LINE INSTALLATION YOUR GAS SUPPLIER OR A QUALIFIED SERVI...

Page 7: ...ill install an unvented gas log set ONLY UNVENTED GAS LOGSETSWHICHHAVEBEENFOUNDTOCOMPLYWITHTHE STANDARDFORUNVENTEDROOMHEATERS ANS IAS AGA Z21 11 2 ARE TO BE INSTALLED IN THIS FIREPLACE NOTE An appropr...

Page 8: ...ramed opening into a living space above a firestop must be placed on the ceiling below Figure 16 Figure 16 When the pipe passes through a framed opening into an attic space above a firestop must be pl...

Page 9: ...e 20 and Rise and Offset Chart Figure 20 A B Maximum length of pipe between supports is 6 feet of angled run Amaximumoftwo6footangledrunsectionsperchimneysystem see Figure 21 Figure 21 FINISHING YOUR...

Page 10: ...50 feet measured from bottom of firebox to flue outlet end of pipe CHIMNEY MAINTENANCE Have your chimney system cleaned and inspected regularly to ensure safe and efficient operation Refer to your Own...

Page 11: ...le termina tion only Figure 27 shows an VRTL 10D round top termination Figure 27 CAUTION DO NOT SEAL OPENINGS ON THE ROOF TOP FLASHING FOLLOW THE INSTALLATION IN STRUCTIONS PROVIDED WITH THE TERMINATI...

Page 12: ...earances are adhered to refer to section on clearances and the firebox opening are not blocked or obstructed in any way see Figure 30 TOP SLOT UNDERNEATH FRAME ADJUSTMENT CLIP ADJUSTMENT CLIP SHORT PI...

Page 13: ...ting a fire this provides adequate outside combustionair Closethemechanismwhennotinusetopreventcold air from entering the room Periodically check your outside air intake vent hood for any possible obs...

Page 14: ...ANGLED RUN PIPE SUPPORT ASSEMBLY V12S 10DM OUTSIDE AIR KIT VAK4 900147 VENT HOOD EMBER PROTECTORS 5 VENT PLASTER COLLAR FRONT PANEL ASSEMBLY CABINET DOOR SET LEFT RIGHT VDGPN36 Cabinet Doors 2 sets an...

Reviews: