Vanguard B) Owner'S Operation And Installation Manual Download Page 16

16

105539

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

®

INSTALLING OPTIONAL
BLOWER ACCESSORY

IMPORTANT

: For clarity, gas valve as-

sembly and grate/burner assembly are not
shown in Figures 31 through 34, page 17.
They will, however, be in your fireplace
when you are installing the blower. Also for
clarity the firebox is shown with dotted
lines.

1.

Open lower louver panel or remove for
easier access.

2.

Place the blower against the lower rear
wall of firebox outer wrapper with the
exhaust port directed upward. Align the
holes in the top mounting tabs of blower
with holes in wall of wrapper (see Fig-
ure 31, page 17). Using the two screws
provided, mount blower and tighten
screws securely.

Note:

 For DA3610T, make sure the

thermal switch is comfortably under the
back of the firebox as shown in Figure
32, page 17.

3.

Be sure to securely attach all wire ter-
minals to terminals on blower motor
(and thermal switch where applicable)
and that the screw retaining the green
ground wire is tight.

4.

Remove screws securing the plate con-
taining the ON/OFF switch to the bot-
tom of the firebox and set aside.

5.

Place speed control against back of this
plate and push the plastic control shaft
through opening (see Figure 33, page 17).

6.

While supporting speed control, secure con-
trol shaft with lock nut by pushing and turn-
ing lock nut with pliers clockwise until tight
against the plate. Place control knob pro-
vided onto shaft (see Figure 33, page 17).

7.

Replace plate containing switches and
tighten screws securely.

NOTICE: If installing blower in an
existing fireplace with gas con-
nections, shut off gas supply and
disconnect heater from gas sup-
ply. Contact a qualified service
person to do this.

CHECK GAS TYPE

Use proper gas type for the fireplace unit
you are installing. If you have conflicting
gas types, do not install fireplace. See dealer
where you purchased the fireplace for proper
fireplace according to your gas type.

FIREPLACE
INSTALLATION

NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

 WARNING: A qualified ser-

vice person must install fireplace.
Follow all local codes.

 CAUTION: This fireplace cre-

ates warm air currents. These cur-
rents move heat to wall surfaces
next to fireplace. Installing fire-
place next to vinyl or cloth wall
coverings or operating fireplace
where impurities (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.

Note: 

Your fireplace is designed to be used in

zero clearance installations. Wall or framing
material can be placed directly against any
exterior surface on the rear, sides, or top of
your fireplace, except where standoff spacers
are integrally attached. If standoff spacers are
attached to your fireplace, these spacers can be
placed directly against wall or framing mate-
rial. See framing details on page 4.

Place the fireplace into position and shim
with noncombustible material if needed.
Nail the side flanges to the framing to secure
the unit in place. There are two floor brack-
ets included with each unit. Use these as an
alternative method of securing the fireplace.

IMPORTANT: 

Make sure fireplace is level

before securing. If fireplace is not level it
will not work properly.

Attaching Thermal Switch to
DA3610T Thermostatically-
Controlled Blower

When installing the DA3610T thermostati-
cally-controlled blower accessory, you must
first secure the thermal switch to the blower.

1.

Remove the two hex head screws on the
blower assembly as shown in Figure 30.

2.

Place the green wire between the bot-
tom hole on the thermal switch bracket
and the bottom hole on the blower as-
sembly.  Insert one of the hex screws
into all three pieces and tighten.

3.

Insert the top screw through the ther-
mal switch bracket and into the blower
assembly. Tighten screw.

4.

Connect the blue wire on the blower
assembly to the right side of the ther-
mal switch.

5.

Connect the black wire to the left side
of the thermal switch.

Installing GA3700/DA3610T
Blowers

Figure 30 - Attaching Thermal Switch to DA3610T Thermostatically-Controlled
Blower Accessory

Blower Assembly

Blue Wire

Green Wire

Black Wire

White Wire

Hex Head
Screws

Thermal Switch
with Bracket

Summary of Contents for B)

Page 1: ...ocedures For as sistanceoradditionalinformation consult a qualified installer ser vice agency or the gas supplier This appliance may be installed in an aftermarket manufactured mobile home where not p...

Page 2: ...This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electri cal Code ANS NFPA 70 or the Cana dian Electrical C...

Page 3: ...BDV Series Figure 2 Vanguard Direct Vent Fireplace DDV Series Glass Door Assembly Blower Adjustment Optional Installation ON OFF Switch Piezo Ignitor Valve Burner Pilot Assembly Log Set Grate Assembly...

Page 4: ...um 1 clearance to combustibles 37 1 2 41 1 2 34 3 4 36 3 4 20 Vertical Termination 19 Horizontal Termination Note Where two numbers are given the top number is exclusive to the 37 Fireplace and the bo...

Page 5: ...d or Simpson Dura Vent GS venting components or kits spe cifically approved for this fireplace Minimum clearance between vent pipes and combustible materials is 1 25 mm except where stated otherwise C...

Page 6: ...side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimum of 24 inc...

Page 7: ...proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount of vertical rise desired The horizon tal...

Page 8: ...ation of pipe and el bows to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs indentations...

Page 9: ...ap Position the vent cap in the center of the 7 1 2 or 10 hole on the exterior wall with the arrow on the vent cap pointing up Insure proper clearance of 1 to combustibles is maintained At tach the ve...

Page 10: ...orner installation UP Horizontal Venting See information in Figure 18 for Vertical V and Horizontal H maximums and minimums The same amounts apply for flexible venting Note Figure 17 applies to rigid...

Page 11: ...max 8 min 8 min 20 max 20 max 8 max 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 20 Horizontal Termi...

Page 12: ...e Pay spe cial attention to these installation in structions for required clearances air space to combustibles when passing through ceilings walls roofs enclo sures attic rafters etc Do not pack air s...

Page 13: ...using a level Temporarily tack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corners down to the roofline and fold th...

Page 14: ...INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Figure 28 Vertical Rigid Venting Conf...

Page 15: ...le Gal vanized Pipe 7 12 Firestop Support Roof Flashing RTV Silicone Vertical Termination and 26 screws D1000 7 x 12 Galvanized Coaxial Pipe 6 pcs D1010 7 x 24 Galvanized Coaxial Pipe 6 pcs D1020 7 x...

Page 16: ...you may run system scirculatingblowerwhile using heater This will help circu late the heat throughout the house In the event of a power outage you can use this heater as your primary heat source WARNI...

Page 17: ...right side see Figure 34 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your fireplace system installati...

Page 18: ...tive to test gauge connection Pur chase the A G A design certified manual shutoff valve from your dealer WARNING A qualified ser vice person must connect fire place to gas supply Follow all local code...

Page 19: ...rough one of the access holes on side of fireplace 3 Attach a 45 flare union gas connector to flexible gas line from gas supply see Figure 37 Connect flare union to flex ible gas line attached to gas...

Page 20: ...ve see Fig ure 38 2 Open propane LPsupply tank valve for propane LPfireplace or main gas valve located on or near gas meter for natu ral gas fireplace 3 Make sure control knob of fireplace is in the O...

Page 21: ...ard off of the lower bracket see Figure 42 4 To replace glass door follow the above instructions in reverse FIREPLACE INSTALLATION Continued Figure 42 Removing Replacing Glass Door Continued Figure 41...

Page 22: ...e firebox see Figure 43 4 Slide the left retainer bracket against the left side brick panel Loosely se cure the bracket screw This secures the left side brick panel 5 Install the right brick panel usi...

Page 23: ...s instructed Do not modify logs Only use logs supplied with fireplace Removeglassdoor SeeRemoving Replacing GlassDoor page21 Installlogsaccordingto instructions for fireplace model numbers Fireplace M...

Page 24: ...see Figure 51 3 Place log 3 crossover assembly onto the front right pin on front burner with the crossover log resting in notch on back log see Figure 52 4 Place lava rock along sides and front of fir...

Page 25: ...ing 8 Turn gas control knob counterclock wise to PILOT 9 Push in gas control knob all the way and hold Immediately light the pi lot by repeatedly depressing the piezo spark ignitor until a flame appea...

Page 26: ...e the louver panel Both the GA3700 manual blower and the DA3610T thermostatically controlled blower have an ON setting and an OFF setting The blower will only run when the switch is in the ON position...

Page 27: ...d Check mechanical supports such as wall straps for rigidity WARNING Turn off fireplace and let cool before cleaning CAUTION Youmustkeepcon trol areas burners and circulat ing air passageways of firep...

Page 28: ...mocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dr...

Page 29: ...om line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 27 or replace burner orifice 1 Adjust the log set so that the flame does not...

Page 30: ...og placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF po...

Page 31: ...ng controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Note Use only original replacement parts Thiswillprotectyourwarrantycoveragefor parts replac...

Page 32: ...c Minimum Inlet Supply Pressure 4 5 w c 11 0 w c 4 5 w c 11 0 w c Dimension Inches mm HxWxD Fireplace 33 x 37 x 18 1 2 33 x 37 x 18 1 2 35 x 41 x 18 1 2 35 x 41 x 18 1 2 838 x 940 x 470mm 838 x 940 x...

Page 33: ...al quick and easy They are designed to go at the top and bottom of the glass door on BDV units Note Remove the plastic film covering on strips before installing on fireplace BRICK LINER D8037A 37 D804...

Page 34: ...3 4 6 7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 29 30 31 32 33 42 34 3 34 2 34 4 34 1 35 36 35 37 38 5 5 5 50 51 39 45 46 35 47 48 49 44 6 41 40 43...

Page 35: ...4502 01 Ignitor Screw 1 24 104503 01 Ignitor Wire 1 25 104504 01 Burner 1 26 104506 01 Orifice 37 1 104506 03 Orifice 41 1 27 104507 01 Brass Elbow 1 28 104508 01 Brass Fitting 2 29 104509 01 Aluminum...

Page 36: ...STRATED PARTS BREAKDOWN BDV37P A B BDV41P A B 1 2 3 4 6 7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 29 30 31 32 33 42 34 3 34 2 34 4 34 1 35 36 35 37...

Page 37: ...23 104502 01 Ignitor Screw 1 24 104503 01 Ignitor Wire 1 25 104504 02 Burner 1 26 104506 02 Orifice 37 1 104506 04 Orifice 41 1 27 104507 01 Brass Elbow 1 28 104508 01 Brass Fitting 2 29 104509 01 Alu...

Page 38: ...KDOWN DDV37N A B DDV41N A B 1 2 3 4 5 5 5 6 6 5 6 7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 33 34 35 36 37 38 47 39 1 39 2 39 3 40 40 40...

Page 39: ...r Natural 37 1 104505 01 Rear Burner Natural 41 1 27 104488 01 Burner Manifold 1 28 104489 01 Burner Gasket 1 29 104506 04 Orifice 37 1 104506 05 Orifice 41 1 30 104506 05 Orifice 1 31 104507 01 Brass...

Page 40: ...7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 33 34 35 36 37 38 47 39 1 39 2 39 3 40 40 40 41 55 54 55 54 59 6 59 56 57 58 55 46 49 45 6 33...

Page 41: ...Rear Burner LP 41 1 27 104488 02 Burner Manifold 1 28 104489 01 Burner Gasket 1 29 104506 07 Orifice 37 1 104506 15 Orifice 41 1 30 104506 06 Orifice 37 1 104506 09 Orifice 41 1 31 104507 01 Brass El...

Page 42: ...sts related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THISEXPRESS WARRANTYEXCLUDESANYANDALLO...

Reviews: