VG-LM250C 250W 3in1 Zoom LED Moving Head Light VG-LM250C 250W 3in1 Zoom LED Moving Head Light
Frost effect
Dimmer: linear dimmer 0-100%
Strobe: 1-25time/s
Pan: 540°
Tilt: 270°
Control and Programming
Control mode: DMX-512; Master/slave mode; Demo mode; Sound active
DMX channel: 16CH, 18CH
Thermal Specification
Maximum ambient temperature: 45 °C (113 °F)
Maximum surface temperature: 170 °C (338 °F)
Electrical Specification
Power supply: Electronic auto-ranging
Input voltage range:
AC90-260V 50/60Hz
Power consumption: 250W
Mechanical Specification
Light size: 320Dx220Wx480Hmm
Weight: 16.5kg
Material: ABS
Appearance color: black
Using Environment
IP rating: IP20
Working temperature: -25-45
℃
Cool system: Fan
Ⅸ
TROUBLE SHOOTING
Following are a few common problems that may occur during operation. Here are some
suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connection of power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
2. If the DMX LED is on and no response to the channel, check the address settings and
DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB
of the unit or the previous one.
4. Try to use another DMX controller.
5. Check if the DMX cables run near or run alongside to high voltage cables that may
cause damage or interference to DMX interface circuit.
C. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor’s drive IC on the PCB might be out of condition.
Ⅹ
MAINTENANCE AND CLEANING
The cleaning of internal and external optical lenses and/or mirrors must be carried out
periodically to optimize light output. Cleaning frequency depends on the environment in
which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater
accumulation of dirt on the unit’s optics.
� Clean with soft cloth using normal glass cleaning fluid.
� Always dry the parts carefully.
� Clean the external optics at least every 20 days. Clean the internal optics at least every
30/60 days.
The following points have to be considered during the inspection:
1) All screws for installing the devices or parts of the device have to be tightly connected
and must not be corroded.
2) There must not be any deformations on the housing, color lenses, fixations and
16