background image

                VG-PB200W  200W  LED  Fresnel  Spot  light  User  Manual                                                VG-PB200W  200W  LED  Fresnel  Spot  light  User  Manual 

intelligent temperature control system, improve the quality of our products stable 

performance, apply to indoor installation. 

Using brand LED chips, integrated encapsulation, improve reliability and long lifespan. 

Using the advanced optical reflective material, make the light on the projection distance 

and brightness is higher than traditional film soft light. 

 

 OVERVIEW AND DIMENSIONS                                                                                                                   

 

   

 

All dimensions are in millimeters 

 

 SAFETY INFORMATION                                                                                                                 

Important 

Every person involved with the installation, operation and maintenance of this device has to 

be qualified and follow the instructions of this manual. Manufacturer will not with 

responsibility for those operations which are not according to this Instruction.   

Verify that the voltage matches the rated voltage. 

When the voltage is 110V, Do not connect more than 10 lightings in total to AC mains 

power in one interconnected daisy chain   

When the voltage is 220V, Do not connect more than 20 lightings in total to AC mains 

power in one interconnected daisy chain   

Before using the fixture, check that all power distribution equipment and cables are in 

perfect condition and rated for the current requirements of all connected devices. 

Always ground (earth) the fixture electrically. 

Avoiding hit the Light when you are move or install the light. 

The minimum distance between light-output and the illuminated surface must be more 

than 0.5 meters. Keep all combustible materials (for example fabric, wood, paper) at least 

0.2 meters away from the fixture. 

Do not expose the fixture to rain or moisture. 

Avoid looking directly into the light source (especially those who suffer from epileptic fits) 

Maximum ambient temperature (Ta) is 40°C. Do not operate fixture at temperatures higher 

than this.   

The Maximum surface temperature is 50°C 

When suspending the fixture above ground level, verify that the structure can hold at least 

10 times the weight of all installed devices. 

Verify that all external covers and rigging hardware are securely fastened and use an 

approved means of secondary attachment such as a safety cable.   

 

 POWER CONNECTION                                                                                                               

03 

02 

Summary of Contents for VG-PB200W

Page 1: ...t light User Manual VG PB200W 200W LED Fresnel Spot light User Manual 200W LED Fresnel Spot Light VG PB200W CE RoHS User Manual Please read this user manual before using this product Keep it for further reference http www vangaa com ...

Page 2: ... chips beads matrix arrangement of large area through the whole aluminum shell to realize heat dissipation naturally we have designed this light This light has high brightness good head dissipation ultra quiet and other features It can satisfy the requirement of indoor movie filming for the lighting layout It is a good substitute of the traditional Fresnel spot light which is very suitable for the...

Page 3: ... the voltage is 220V Do not connect more than 20 lightings in total to AC mains power in one interconnected daisy chain Before using the fixture check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices Always ground earth the fixture electrically Avoiding hit the Light when you are move or install the light The ...

Page 4: ...cian RELAYING POWER TO OTHER DEVICES The lightings can be linked in a chain by power cables which installed a blue and a light gray connectors on the two ends The light gray connector connects to the power out socket of the first lighting and the blue connector connects to the power in socket of the subsequent lighting and so on The power cable must is a three conductor 2 5mm2 cable When the volta...

Page 5: ...rrent menu and save the selected item or parameter MAIN MENU The way into the menu as below 1 Press ENTER when the display show the title information 2 Press UP or DOWN button to choose the right menu which you need 3 Press ENTER into the menu 4 Press UP and DOWN button to set the parameter or setting 5 Press ENTER to save the setting 6 Press MENU SET button to back MENU MAP LCD SHOW Function Inst...

Page 6: ...r temperature 5 Press UP DOWN to choose Set auto mode Dimmer menu then press ENTER into the adjust function of the LED 6 Press UP DOWN to adjust the brightness 000 light off 255 Max brightness after the setting press ENTER to save 7 Press twice MENU SET button to back the title mode the second line will shows Master Auto the setting is ok The sound active mode based on the light has the sound acti...

Page 7: ... Light visor optional IP rating IP20 Housing material aluminum alloy Working temperature 25 40centigrad degree Ⅸ APPENDIX Problem and solution Problem Reason Resolution Device not work No power AC100 240V 50 60Hz Check the power connection and make sure device connect the mains in well condition Check if the fuse is good LED Bulb is off LED bulb damaged Replacing LED bulb LED drive board damaged R...

Reviews: