background image

V&P Scientific, Inc. 

Technical Note 455 

 

 
 
 
 

Technical Note 455 

 

OPERATION MANUAL FOR 

VP 741ECE-3Z-KIT-96 

 

 

 

 

Figure 1. Components of VP 741ECE-3Z-KIT-96 

(*glass shell vials not included) 

 

Warning:

 

Avoid attempting to move the 3-Zone heating block 

after heating has begun, it can become quite hot 

and cause burns if touched. 

 
 

 

Summary of Contents for VP 741ECE-3Z-KIT-96

Page 1: ...e 455 OPERATION MANUAL FOR VP 741ECE 3Z KIT 96 Figure 1 Components of VP 741ECE 3Z KIT 96 glass shell vials not included Warning Avoid attempting to move the 3 Zone heating block after heating has beg...

Page 2: ...quired components it is ready to be sealed STEP1 Place one VP 416 96 FILM clear PFA sheet sold separately over the vials taking care to align the center hole of the film and the center hole of the rea...

Page 3: ...unnecessary and may strip the threads As an illustration note starting position of tightening puck at 12 o clock position followed by fully tightened position at 5 o clock position 3 Following the pre...

Page 4: ...socket head connectors to their respective ports Note that each are labelled ZONE 1 ZONE 2 ZONE 3 see Figure 6 2 Plug power cable into the port at the back of the control box as well as into the wall...

Page 5: ...Inc 5 Technical Note 455 3 Note that location of each temperature zone is indicated on the side of the red anodized heating block as shown in Figure 8 Figure 8 Side view of heating block showing 3 tem...

Page 6: ...C 5 From the touchscreen interface tap the SP button to bring up the Set Point temperature screen as seen in Figure 9 Input desired temperature by hitting Enter button Figure 9 Setting desired tempera...

Page 7: ...ne heating block Warning Avoid attempting to move the 3 Zone heating block after heating has begun it can become quite hot and cause burns if touched 8 Once reaction time is complete set the temperatu...

Page 8: ...erature internal reaction temperature correlation i e desired set temperature 50degC then internal reaction temperature is also 50degC 2 Should you wish to access calibration offsets menu to adjust th...

Page 9: ...ration Offset as desired f Once Calibration Offset is changed select Done then Home Screen buttons 3 You may need to repeat this process of adjusting Calibration Offset and testing internal temperatur...

Page 10: ...ied period of time because of a defect in material or workmanship V P Scientific will at its option repair or replace the product Damage to the product caused by user negligence is not covered Please...

Reviews: