background image

 

A6V10276498_b  

en 

1.  EC declaration of conformity 

Hereby Vanderbilt International (IRL) Ltd declares that this 
equipment type is in compliance with all relevant EU Directives for 
CE marking. From 20/04/2016 it is in compliance with Directive 
2014/30/EU (Electromagnetic Compatibility Directive). 

The full text of the EU declaration of conformity is available at the 
following internet address: 

http://pcd.vanderbiltindustries.com/doc/Seismic

. 

2.  Application 

The GM775LSNi seismic detector is compatible with both types of 
local security network LSNi & LSN and has a loop connection to 
the control panel. The detector reliably detects attempted break-
ins to safes, ATMs, night deposits, lightweight safes, strong rooms 
and modular steel or concrete vaults. Intelligent signal processing 
enables detection sensitivity to be set individually and therefore 
reliably ensures no false alarms. The anti-tamper system for the 
cover (Fig. 1, item A) and on the back of the GM775LSNi will 
detect the opening or the forcible removal of the detector. 

 

Installation, programming and commissioning must be 
performed by specialists. 

3.  Contents 

 

1 x GM775LSNi seismic detector 

 

1 x GM7xx drill template 

 

3 x cable ties 

4.  Coverage area 

The area monitored by the detector is referred to as the coverage 
area. It covers the area around the detector with an operating 
radius (r). 

Detector coverage 

 

Joints in the construction of the vault may impair the transmission 
of the signal. Doors must have their own detector installed to 
provide the correct coverage. 

Tightly sealed corners and edges may reduce the operating radius 
(

r

) by >25%, therefore, corners and edges on steel vaults must be 

seamlessly welded. Incorrect positioning can reduce the coverage 
area. It is recommended that detectors are installed on each plane 
(walls, floor, and ceiling) of the protected area. Coverage from 
adjoining planes should not form part of a comprehensive 
protection strategy. 

4.1.  Detector spacing distance 

Detectors should be positioned so that they cover the entire area 
to be monitored. The distance between detectors is referred to as 
the spacing distance (

sd

). 

Detector spacing distance (sd) 

 

To ensure complete coverage of the protected area, the following 
formula should be applied to determine the correct spacing 
distance between seismic detectors. 

Spacing distance (

sd

) = operating radius(

r

) x 2 x 0.75 

Example: 

Material 

Operating 

radius 

Spacing 

distance 

Steel 

2m 

3m 

Concrete 

4m 

6m 

LWS (Systems of armour plating 
with synthetic/composite materials) 

1.5m 

2.25m 

5.  Installation 

5.1.  Direct Installation on steel 

The GM775LSNi seismic detector can be installed directly onto a 
flat, even metal surface. 

 

Take note of the orientation of the GM775LSNi seismic 
detector and the required drill pattern. 

 

There must be a direct connection between the detector 
and the mounting surface. Paint, varnish, dirt, silicone or 
similar materials will impede the acoustics. Remove 
these materials from the mounting location before 
installation. 

Use the GM7xx drilling template (provided) to determine the 
location of the required holes. 

1.  Drill 3 x 3.2mm holes, 6mm deep. 2 holes for the detector and 

1 hole for the GMXS1 internal test transmitter (Fig. 1, item H). 

2.  Remove the drilling template. 
3.  Thread all holes to M4. 
4.  Secure the detector and the test transmitter to the mounting 

surface. 

5.2.  Installation on steel using the GMXP0 mounting plate 

Use the weld symbol side of the GMXP0 mounting plate (Fig. 2) to 
install the detector on uneven or reinforced steel surfaces. 

 

The GMXP0 mounting plate can be used for installing a 
seismic detector on a steel surface. It is essential to use 
the correct side and mounting methods. The GMXP0 
displays a detector symbol to indicate the direction of 
the cable access to the detector. 

 

Take note of the orientation of the GM775LSNi seismic 
detector and the required orientation of the GMXP0 
mounting plate. 

 

GMXP0 weld symbol 

 

Detector symbol showing cable access at top   

1.  With the weld symbol visible, attach the GMXP0 to the 

mounting surface using two fillet welds as shown (Fig. 3, item 
B). 
If welding is not possible, use the GMXP0 as a drill template. 

 

Mark the 3 centrally located countersunk holes (Fig. 3, 
item A). 

 

Drill 3 x 3.2mm Ø holes (depth to be determined by the 
thickness of the mounting surface). 

 

Thread to M4. 

 

Secure the GMXP0 using 3 x M4 countersunk screws 
(provided with GMXP0). 

2.  Mount the detector on to the GMXP0. 
3.  Mount the GMXS1 internal test transmitter on the designated 

location on the GMXP0 (Fig. 3, item C) and connect to the 
detector (Fig. 1, item E). 

5.3.  Installation on concrete using the GMXP0 mounting 

plate 

Use the drill symbol side of the GMXP0 mounting plate (Fig. 4) to 
install the detector on concrete surfaces. 

Summary of Contents for GM775LSNi

Page 1: ...A6V10276498_b 1 GM775LSNi en Seismic detector de Körperschallmelder Installation manual A6V10276498_b Edition 01 10 2015 A5Q00038199 1 2 3 4 5 6 ...

Page 2: ...A6V10276498_b 2 7 ...

Page 3: ... the correct spacing distance between seismic detectors Spacing distance sd operating radius r x 2 x 0 75 Example Material Operating radius Spacing distance Steel 2m 3m Concrete 4m 6m LWS Systems of armour plating with synthetic composite materials 1 5m 2 25m 5 Installation 5 1 Direct Installation on steel The GM775LSNi seismic detector can be installed directly onto a flat even metal surface Take...

Page 4: ...6 8 Configuration addressing LSNi LSN GM775LSNi supports LSNi LSN improved and LSN LSN classic The detector must be configured using the two DIP switches Fig 1 items G and J before the power supply is connected via the LSNi LSN bus The DIP switches are used for configuration and addressing as follows Fig 1 item G Addressing Fig 1 item J Material and coverage application The following configuration...

Page 5: ...With the cover removed scratch the metal case of the detector with a screw driver Activate the GMXS1 internal test transmitter through the control panel using a seismic test function Apply the required input to activate the GMXS5 external test transmitter if provided Simulate an attack on the protected space Carefully replace the cover and secure it in place 13 Service The function of the detector...

Page 6: ...eldautomaten Nachttresoren Leichtbausafes Stahlkammern und modularen Tresor räumen aus Stahl oder Beton Die intelligente Signalverarbeitung erlaubt eine individuelle Einstellung der Detektionsempfindlichkeit und somit eine hohe Sicherheit gegen Falschalarm Der Sabotageschutz in der Melderabdeckung Abb 1 Element A und auf der Rückseite des GM775LSNi erkennt ein Öffnen und ein gewaltsames Entfernen ...

Page 7: ...tte GMXP0 kann für die Montage eines Körperschallmelders auf einer Betonfläche verwendet werden Es ist ausschlaggebend dass die richtige Seite und die korrekten Montagemethoden verwendet werden Die GMXP0 trägt ein Meldersymbol das die Ausrichtung der Kabelzuführung zum Melder anzeigt Achten Sie darauf dass der Körperschallmelder GM775LSNi und die Montageplatte GMXP0 zueinander ausgerichtet sind GM...

Page 8: ...tionsbedingten Geräuschen 9 Programmierung über LSNi LSN Zentrale Die Programmierung des Melders erfolgt über die Konfigurationssoftware der entsprechenden Zentrale 10 Wirkradius Der angegebene Wirkradius gilt für einen Angriff mit Sauerstofflanze Bei einem Angriff mit mechanischem Werkzeug z B Bohrer kann sich der Wert bis auf das Dreifache erhöhen Der angegebene Wirkradius ist ein Richtwert der ...

Page 9: ...400 bis 500 mm mit einer 30 bis 40 mm langen Schweißnaht verschweißt sein 3 Eckverbindungen bei Wandelementen müssen durchgehend verschweißt werden wenn der Wirkbereich sich auch über die Ecken erstrecken soll 4 Werden Wandelemente mit Meldern bestückt kann das direkt angrenzende Boden und oder Deckenelement in den Wirkbereich mit einbezogen werden wenn die entsprechende Stoßstelle durchgehend ver...

Page 10: ...lossschutz GM7xx VBPZ 3470190001 GMXP3Z Schlossschutz GM7xx VBPZ 5712410001 GMAS6 Bewegliches Montagekit GM7xx VBPZ 4886060001 GMXD7 Bohrschutzfolie 10 GM730 760 775 VA5Q00006245 GMXC2 Anschlussmuffe 16 mm GM7xx V54534 F101 A100 ...

Page 11: ... 1 0 1 0 0 0 1 38 0 0 1 0 0 1 1 0 124 0 1 1 1 1 1 0 0 210 1 1 0 1 0 0 1 0 39 0 0 1 0 0 1 1 1 125 0 1 1 1 1 1 0 1 211 1 1 0 1 0 0 1 1 40 0 0 1 0 1 0 0 0 126 0 1 1 1 1 1 1 0 212 1 1 0 1 0 1 0 0 41 0 0 1 0 1 0 0 1 127 0 1 1 1 1 1 1 1 213 1 1 0 1 0 1 0 1 42 0 0 1 0 1 0 1 0 128 1 0 0 0 0 0 0 0 214 1 1 0 1 0 1 1 0 43 0 0 1 0 1 0 1 1 129 1 0 0 0 0 0 0 1 215 1 1 0 1 0 1 1 1 44 0 0 1 0 1 1 0 0 130 1 0 0 0 ...