background image

vanco1.com | 800.626.6445  

6x6 audio matrix with 6 bridgeable zones to 

accomodate 1 or 2 speakers per zone

6X6 AUDIO DISTRIBUTION

AMPLIFIER

VANCO PART NUMBER PA66MK2

Summary of Contents for PULSEAUDIO RPA66MK2

Page 1: ...vanco1 com 800 626 6445 6x6 audio matrix with 6 bridgeable zones to accomodate 1 or 2 speakers per zone 6X6 AUDIO DISTRIBUTION AMPLIFIER VANCO PART NUMBER PA66MK2 ...

Page 2: ...lug unit during lightening storms or when not used for an extended period of time A surge protector is strongly recommended 8 Protect the power cord from being walked on or pinched particularly at the plugs 9 Use unit only with accessories specified by the manufacturer 10 Refer all servicing to qualified personnel WARNING CAUTION THIS PRODUCT IS 100 INSPECTED AND TESTED IN THE UNITED STATES TO VER...

Page 3: ...se Audio Control System expandable up to 3 units for 18 Zones of distributed audio RS232 IP adapter and Android and IOS app allows for effortless control via smartphone or tablet Optional keypads with modern design fit seamlessly into any room Keypads are POE with built in IR Receivers Keypads and 1 Cat5e Cat6 Connection Hub sold separately as PA66ACCS High efficiency Class D amplification Stereo ...

Page 4: ...uency Response 20Hz 20KHz Input Impedance 47 K Ohm Input Sensitivity 250 mv Protection Function Overload Protection Short Circuit Protection Over Temperature Protection System on Voltage DC 12V External Mute Voltage DC 12V Power Supply AC115V 60Hz 230V 50Hz Output Connection Terminal Block Dimension 16 9 W x 3 5 H x 16 4 D Weight 25 lbs ...

Page 5: ...led on Amp Speaker Terminal Blocks 6 Installed on Amp AC Power Cable Product Manual Remote Control Keypad Connection Hub and Decora Wall plate Keypad Mounting Hardware Keypad hub 6 PoE Keypads with built in IR RX and decora wall plates IR Receiving Cable AC Power Cable Product Manual PA66MK2 PA66ACCS sold separately ...

Page 6: ...ts Input 1 PA 5 Status Used to control external zone devices 6 IR Outputs to control sources 7 A PA Trigger IN Source 1 B MUTE In Control Out This input can temporarily mute the system by connecting this unit to a relay closure switch on home automation system or phone system etc When switch is on it will short circuit the input and mute the unit 8 IN OUT Port Daisy chain additional PA66MK2 units ...

Page 7: ...s disconnected before making ANY connections to the main unit and attached devices 2 Install in a well ventilated environment 3 Ensure any vents are not blocked to allow for proper circulation 4 Do not install above or below sources of heat 5 Use good quality cabling 6 The unit can be installed within a rack using the provided mounting rack ears ...

Page 8: ...hones may require a 3 5mm Stereo to RCA Cables in order to connect to the PA66MK2 NOTE Input 1 can be used as a global input for all zones when a source is connected to Input 1 and the 12VDC is applied to the PA IN jack tip is positive then source 1 will broadcast to all zones If no 12VDC is applied then the first input will be operating under normal conditions CONNECTING THE SOURCES ...

Page 9: ...ermine modes for each zone Number 2 Panel Descriptions page 5 Once you have properly identified the desired mode strip about of insulation and twist the copper strands Connect the speaker wire to there screw down terminal as indicated on the amp To loosen the terminal turn counterclockwise and to tighten the terminal turn clockwise For better quality we recommend used 12 14 AWG stranded copper spe...

Page 10: ...ach of the 6 outputs These can be used to connect an additional amplifier expand zones or to connect a powered subwoofer The Pre amp output levels are not fixed and are able to be controlled via RS232 and IP using the provided RS232 IP adapter as well as keypads and IR sold separately in the PA66ACCS ...

Page 11: ...C trigger outputs which correspond to the six output zones When a zone is powered ON by the PA66ACCS keypad the corresponding zone sends 12Vdc to the trigger output jack The triggers can be used to automatically switch peripheral equipment ON or OFF WIRING 3 5mm Mono ...

Page 12: ...IGGER OUTPUT Zone OFF 12Vdc removed from the TRIGGER OUTPUT CONTROL When any zone is on 12Vdc applied to the CONTROL OUT When All zones are OFF 12Vdc removed from the CONTROL OUT Trigger Inputs PA IN Apply 12Vdc for input 1 override on all six zones MUTE IN Apply 12Vdc to mute all zones ...

Page 13: ...tions for this Master Slave 1 and Slave 2 which help identify each unit CASCADING SOURCES INTO ADDITONAL ZONES Once each unit is correctly addressed use the provided ribbon cables to connect the OUTPUT of the original MASTER unit into the INPUT of Slave 1 To cascade the sources into a third unit using the provided expansion ribbon cable go out of the OUTPUT port from the device addressed as SLAVE ...

Page 14: ... entertainment and home theater applications LIABILITY STATEMENT Every effort has been made to ensure that this product is free of defects The manufacturer of this product cannot be held liable for the use of this hardware or any direct or indirect consequential damages arising from its use It is the responsibility of the user and installer of the hardware to check that it is suitable for their re...

Page 15: ...ications inadequate maintenance and care or use in any manner for which the product was not originally intended Items integrated into Vanco products that are made by other manufacturers notably computer hard drives and liquid crystal display panels are limited to the term of the warranty offered by the respective manufacturers Such specific warranties are available upon request to Vanco A surge pr...

Page 16: ...506 Kingsland Drive Batavia Illinois 60510 call 800 626 6445 fax 630 879 9189 visit www vanco1 com Vanco International Introducing a new brand from Learn more at pulseaudio1 com ...