Warranty & Service

VanGuard microscopes are warranted by VEE GEE Scientific LLC 

to be free from defects in material and workmanship for a period 

of five (5) years from the date of purchase, except for electrical 

components which have a one (1) year limited warranty. During 

this period, VEE GEE Scientific, or its authorized service station, 

will at their option and without charge, either repair or replace any 

part found to be defective in materials or workmanship.

This warranty is subject to the following limitations and exceptions 

and will not apply if:
1) There is lack of proof of date and place of purchase. The 

purchase invoice must accompany the unit when sent in for repair. 

The warranty extends to the original consumer purchaser only and 

is not assignable or transferable.
2) The damage is due to normal wear and tear, misuse, abuse, 

negligence, accident, inadequate maintenance, disregard 

for operating instruction, or to any other cause not due to the 

manufacture of the microscope (e.g., objective failure because of 

oil penetration due to lack of timely cleaning).
3) The serial numbers, names, and/or functions are altered or 

obliterated; or unauthorized repair or replacement of parts by the 

End-User or an unauthorized third party while under warranty.
4) Consumable items (such as, but not limited to, bulbs) have failed.

This warranty expressly excludes transportation damage and 

adjustment or readjustment. In no case shall VEE GEE Scientific 

be liable to the Buyer or any person for any special, indirect, 

incidental, or consequential damage whether claims are based 

in contract or otherwise with respect to or arising out of product 

furnished hereunder. For goods manufactured by any third party, 

VEE GEE Scientific’s liability under warranty is limited to the terms 

of the warranty by the supplier for the goods. All warranty work 

shall be performed at the authorized service center. Contact your 

distributor or VEE GEE Scientific to discuss the problem and obtain 

instructions for the return of your microscope for repair. The original 

purchaser returning this product must prepay all postage, shipping, 

transportation, packaging, and delivery costs.

5 Year Limited Warranty

 

Contact Information:

Toll Free 

 

800-423-8842

Email 

  [email protected]

   

 

[email protected]

Web 

  veegee.com

If you experience problems setting up your 

microscope or have service related questions 

please contact your dealer or VanGuard

Microscopes directly at 1-800-423-8842.

O u r   s t a n d a r d   b u s i n e s s   h o u r s   a r e

7:00 a.m. - 5:00 p.m. Central Standard Time.

Summary of Contents for 1400 Series

Page 1: ...Covering Models 1420BR 1421BR 1430BR 1431BR 1423PH 1433PH Operation Manual 1400 Series...

Page 2: ...ide holder and a chemical resistant finish Motion is controlled by a right hand low position coaxial control and is driven by a rack and pinion system Focusing Movement Coaxial ultra low position coar...

Page 3: ...el 1423PH Binocular Head 1 ea Stand 1 ea Phase Contrast Condenser 1 ea Phase Contrast Centering Telescope 1 ea 10X Eyepiece 2 ea 10X Plan Phase Objective 1 ea 20X Plan Phase Objective 1 ea 40X Plan Ph...

Page 4: ...art Numbers Scale Reticle Call for Part Numbers Stage Micrometer Call for Part Numbers 20X Eyepieces Call for Part Numbers Objectives Achromatic 4X 10X 20X 40X 60X 100X oil Plan Achromatic 4X 10X 20X...

Page 5: ...Port Mechanical Stage Head Assembly Focusing Tension Control Knob Prism Slider Camera Port Dust Cap Phase Annulus Turret Substage Adjustment Knob Diopter Adjustment Mechanism Interpupillary Adjustment...

Page 6: ...6 1400 Series Parts Power Cord Jack 1400 Series Rear View Carrying Handle Power Switch Variable Lighting Control Up Stop Mechanism 1400 Series Lower Left View Substage Adjustment Knob...

Page 7: ...set screw using the included hex wrench see figure 1 NOTE Do not release the head until it is firmly secured with the head set screw Assembly 1 2 3 4 5 Figure 2 Figure 3 7 All Models If you are setti...

Page 8: ...re 6 Make sure that the text NA 1 25 is facing up as you install the condenser If the condenser will not slide freely through the silver ring and you ve checked that the condenser set screw is backed...

Page 9: ...condenser assembly While looking into the microscope eyepieces close the field iris diaphragm to the smallest setting by turning the uppermost section of the substage illuminator counter clockwise Cl...

Page 10: ...contrast centering telescope should resemble rings superimposed on one another see Figure 7A What is actually being viewed are the phase rings Turn the condenser centering knobs which extend from the...

Page 11: ...stage X Y controls located underneath the right hand side of the stage see figure 9 provide easy and accurate positioning of the sample One complete turn of the longitudinal Y control lower half of th...

Page 12: ...t mechanism located on the right eyetube see figure 12 Once complete the microscope is corrected for your vision Interpupillary and Diopter Adjustments Figure 12 Figure 11 1 2 3 The 100X objective whi...

Page 13: ...vert the image to the camera port The prism slider is the silver knob on the right side of the head assembly see figure 13 Note The 1400 Series Microscopes utilize a 70 30 split sliding prism This spl...

Page 14: ...s is blackened pull the fuse out of it s holder and snap a new fuse in You might need to use a screwdriver to lever the fuse out but be careful not to scratch the circuit board Replace the rear cover...

Page 15: ...1 8mm F O V Plan Achromatic 20X 0 40 N A 0 50mm W D 0 9mm F O V 40X 0 65 N A 0 40mm W D 0 45mm F O V 100X 1 25 N A 0 25mm W D 0 18mm F O V Stage Dimensions 140mm x 140mm Stage Motion Right Hand Coaxia...

Page 16: ...ir or replacement of parts by the End User or an unauthorized third party while under warranty 4 Consumable items such as but not limited to bulbs have failed This warranty expressly excludes transpor...

Page 17: ...Printed in the USA No VGMNL081919 1400BR PH...

Reviews: