Montagehandleiding Enpres
Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands
+31 174 515 050 · [email protected] · www.vanderendegroep.com
Page 16 of 30
IMPROVING YOUR BUSINESS
With a petrol powered Enpres:
fill the tank with petrol
check the oil level of the engine
4.3 Actions before use:
check the oil level with the dipstick (26) or with the oil level indicator (24);
o
the oil level should be above the marking;
check whether all connections are correctly connected;
check whether all lines are securely connected;
check whether the guard (3) is securely connected;
check whether the handle (16) is in the vertical position;
put the main switch on;
start the motor for 5 to 10 seconds
o
do not exceed this time, the pump is running without fluid and will overheat otherwise;
o
if possible, help filling the suction line;
after a 30 second break, start the motor for another 5 to 10 seconds;
repeat this sequence until there is fluid coming out of the overflow connection (20);
the pump is now ready for use.