background image

ELECTRIC BICYCLE METER KT

LCD7 Product User Manual

 

- 17 -

P2 parameter setting interface 

P2  is  wheel  speed  pulse  signal  setting,  if  wheel  generated  1  pulse  signal  by  a 

revolution,  P2  should  be  set  as1.  If  wheel  generated  6  pulse  signals  by  a  revolution,  P2 

should be set as 6. If users didn’t configure the pulse signal system, and then P2 parameter 

setting can be 0. The setting range of  P2 should be between 0-6, hold 

button (

UP

shortly or 

  button 

(DOWN) 

for selection. 

Under P2 parameter setting interface, if there’s no button operation on the meter 

for  more  than  1  minute,  and  then  the  meter  will  automatically  return  to  display  1, 

and the original set parameter will be saved. 

After  finishing  P2  parameter  setting,  hold 

  button  (

SW

)  shortly  to  save  the 

current set values and enter P3 parameter setting interface. 

Please Note

when P2 parameter is set to be 0, for the built-in clutch motor, there will 

be the following defects, when the internal motor rotors stop or the internal rotor speed is 

lower than the outer rotor speed, then the speed displayed on the meter is inaccurate! 

P3 Power-assist Control Mode Setting

Enter  P3  parameter  setting  interface  after  P2  parameter  setting  is  finished,  and  P3 

parameter column flashes. 

  P3 parameter setting interface 

P3  is  for  power-assist  control  mode  setting,  when  P3  parameter  setting  is1,  power- 

Summary of Contents for KT-LCD7

Page 1: ...User Manual KT LCD7 eBike Special Meter www vamoosecycle com...

Page 2: ...Content 5 Normal Operation 5 On Off 5 Display Interface 6 Display 1 6 Display 2 7 Display 3 8 Display of Turned on Throttle 9 Display of Power assist Startup 9 PAS Ratio or Throttle Gear Switch 9 Pus...

Page 3: ...ting 19 C2 Motor Phase Classification Coding Setting 20 C3 Power assist Ratio Gear Initialization Setting 21 C4 Throttle Function Setting 22 C5 Controller Maximum Current Adjustment Setting 23 C6 Back...

Page 4: ...properly which help you resolve the problems appeared in practical use Outlook and Size Meter Dimension Main Material and Color PC material is mainly used for KT LCD7 meter and the housing color is d...

Page 5: ...peed display with displays of real time speed KM H or MPH and a single maximum speed MXS and a single average speed AVS Trip distance display with displays of a single trip distance DST and total trip...

Page 6: ...al Operation On Off Hold button SW long the meter is powered on and into normal operation and it provides the controller with power supply Under normal operating status hold button SW long the meter i...

Page 7: ...rface Display 1 The meter is startup to enter display 1 Display 1 The followings are shown on display 1 Battery Capacity Indicator Single Trip Time TM Display Power Assist Ratio Gear ASSIST Real time...

Page 8: ...hts and Headlights Status Brake Status Cruise Function Display Power assist Startup Display Throttle Turned on Display Bluetooth connection display Display 2 In display 1 hold button SW shortly to ent...

Page 9: ...5 seconds display 2 automatically returns to display 1 Display 3 In display 2 hold button SW shortly to enter display 3 Display 3 The followings are shown on display 3 Single Maximum Speed MXS Real ti...

Page 10: ...terface shows the sign of turned on throttle see the Figure below The sign will be off automatically after about five seconds Display of Power assist Startup The meter is driving with power assist und...

Page 11: ...zero there s no power assist function Power Assistant Push Function Users can use 6KM H power assist function when pushing vehicles Hold button DOWN the meter assist function logo flashes the vehicle...

Page 12: ...ave headlights driving and output functions meter backlighting and vehicle lights power logo light hold button UP long again to turn off backlights and vehicle headlights Battery Capacity Indicator Th...

Page 13: ...the button UP and the button DOWN simultaneously for about 2 seconds the single trip time TM and single trip distance DST flicker then hold button shortly SW the record contents of both will be cleare...

Page 14: ...t circuit Abnormality User Setting Project KT LCD7 meter user setting project General project setting P parameter setting C parameter setting General Project Setting Maximum Trip Speed Under power off...

Page 15: ...ing speed setting enter the wheel diameter setting interface and then the wheel diameter display column flashes Hold button UP or button DOWN to choose the corresponding wheel diameter specification t...

Page 16: ...no button operation on the meter for more than 1 minute and then the meter will automatically return to display 1 and the original set units will be saved After finishing the metric imperial units se...

Page 17: ...P1 motor gear reduction ratio number of rotor magnet pieces just rounding if there s any decimal After entering P parameter setting environment the first is to set P1parameter P1 parameter column flas...

Page 18: ...te and then the meter will automatically return to display 1 and the original set parameter will be saved After finishing P2 parameter setting hold button SW shortly to save the current set values and...

Page 19: ...parameter setting is finished P4 parameter column flashes P4 parameter setting interface P4 is throttle startup setting when P4 setting is 1 indicating the throttle is under non zero startup mode name...

Page 20: ...eter setting interface Or hold button SW long for about 2 seconds to exit P parameter setting environment and return to the display 1 Exit P Parameter Setting Among the five P parameter settings when...

Page 21: ...rt Sensitivity Forward 5 Signal 00 Standard Reverse 6 Signal 05 Standard 01 Lower 06 Lower 02 Lowest 07 Lowest Forward 8 Signal 00 Higher Reverse 10 Signal 05 Higher 01 Standard 06 Standard 02 Lower 0...

Page 22: ...on DOWN for selection After finishing C2 parameter setting hold button SW shortly to save the current set values and enter C3 parameter setting interface C3 Power assist Ratio Gear Initialization Sett...

Page 23: ...ce after C3 parameter setting is finished C4 parameter column flashes C4 parameter setting interface C4 is throttle function setting the setting range is 0 4 hold button UP or button DOWN for selectio...

Page 24: ...for short to make selection and the default value is 50 The percentage values of other gears divide automatically in equal After finishing C4 parameter setting hold button SW shortly to save the curre...

Page 25: ...current value ie limit current value when setting is 9 maximum current value divided by 1 10 when setting is 8 maximum current value divided by 1 15 and so on After finishing C5 parameter setting hol...

Page 26: ...nterface after C6 parameter setting is finished C7 parameter column and CRUISE sign flashes C7 parameter setting interface C7 is cruise function setting the setting range is 0 or 1 hold button UP or b...

Page 27: ...setting is finished C9 parameter column flashes C9 parameter setting interface C9 is meter power on password setting the default value is 0 hold button UP or button DOWN shortly for selection C9 param...

Page 28: ...oded After finishing C9 parameter setting hold button SW shortly to save the current set values and enter C10 parameter setting interface C10 Automatically Restore Default Setting Enter C10 parameter...

Page 29: ...ace C11 is meter attribute selection setting the setting range is 0 2 hold button UP or button DOWN shortly for selection C11 parameter definition table C11 value Meter Attribute 0 Meter uses LCD3 new...

Page 30: ...lashes C12 parameter setting interface C12 is controller minimum operating voltage adjustment setting tiny adjustment of voltage shortage the default value is 4 and the setting range is 0 7 hold butto...

Page 31: ...SW shortly to save the current set values and enter C13 parameter setting interface C13 ABS brakes of the controller and parameters of anti charge control Setting Enter into C13 parameter setting inte...

Page 32: ...setting interface C14 parameter bar flashes C14 parameter setting interface C14 is the parameters of power assist tuning setting with the default value of 2 The power assist is between1 4 gear and it...

Page 33: ...parameters include general project parameter P parameter and C parameter of all KT LCD7 meter produced by our company according to requirements and set the meter to be a data source according to the...

Page 34: ...meter can only copy parameter of the same meter model User Setting Note After entering the user setting environment if there s no button operation on the data for more than 1 minute the meter will au...

Reviews: