4. CLEANING AND MAINTENANCE
Cleaning.
1.
Close the
Mixer air stopcock
(14)
, close the
Resin pump air stopcock (3)
and close
the
Catalyser pump air stopcock (9)
.
2.
Keep the
resin valve (5)
and the
resin pump air control
(12)
closed.
3.
Remove the
absorption (6)
and place in cleaning solvent.
4.
Open the
Catalyser pump bleed (11)
(pressure tank), release the air an open the
cover of the
catalyser pump
(8)
(pressure tank).
5.
Fill the
catalyser pump (8)
(pressure tank) with cleaning solvent.
6.
Follow steps 4 and 5 for pressure tank
resin pumps (1)
.
7.
Replace the
catalyser pump (8)
cover, making sure that it is properly closed.
8.
Open the
Mixer air stopcock
(14)
, open the
Resin pump air stopcock (3)
and open
the
Catalyser pump air stopcock (9)
.
9.
Open the
resin valve (5)
and the
resin pump air control
(12)
.
10. Squeeze the
gun trigger (18)
until clean solvent –free of resin and catalyser residue-
is expelled.
11. Close the
Mixer air stopcock
(14)
, close the
Resin pump air stopcock (3)
and close
the
Catalyser pump air stopcock (9)
.
12. Always leave the equipment PRESSURISED. Loaded with pressurized cleaning
solvent.
Maintenance.
1.
Clean the TRIMIX® mixer head (17) frequently when in use.
2.
Always leave the
TRIMIX® mixer head (17)
immersed in cleaning solvent. When left
unused for long periods, place in a tightly sealed recipient with solvent. This will
impede the evaporation of the solvent and the catalyser outlets becoming blocked
by any remaining residue.
3.
Clean the equipment each day with the cleaning solvent recommended by the
manufacturer and which we applied to the
resin pump (1)
(dual membrane or
pressure tank) to avoid blockage from resin residue.
4.
Clean the equipment each day with the cleaning solvent recommended by the
manufacturer and which we applied to the
catalyser pump (8)
(pressure tank) to
avoid blockage from the catalyser.
5.
Check the gun, anti-pulsation chamber or absorption filters between the 1st and the
2nd cleaning.
6.
Grease the exchange valves in dual membrane units ONCE PER WEEK when the
equipment is in use.
The equipment is to be subjected to an initial revision some 3 months after installation. This
check is to cover all the
AIRBRUSH MANUAL EXTERNAL MIX EQUIPMENT’S spray
equipment
, as well as the correct operation of all the equipment’s safety systems. If
everything is as it should be after the service check, further service checks are to be carried
out every six months until the end of the guarantee period. After the guarantee expires, the
frequency of service checks will be agreed with the client.
Summary of Contents for AIRBRUSH MANUAL EXTERNAL MIX EQUIPMENT
Page 1: ......
Page 22: ...INSTRUCTIONS MANUAL AIRBRUSH MANUAL EXTERNAL MIX EQUIPMENT 21 APPLICATION GUN EXPLODED...
Page 23: ...INSTRUCTIONS MANUAL AIRBRUSH MANUAL EXTERNAL MIX EQUIPMENT 22...
Page 24: ...INSTRUCTIONS MANUAL AIRBRUSH MANUAL EXTERNAL MIX EQUIPMENT 23...
Page 25: ...INSTRUCTIONS MANUAL AIRBRUSH MANUAL EXTERNAL MIX EQUIPMENT 24...