background image

Page 1

Read Before Use – Safety Information

 

Warning

To prevent possible electrical shock, fire, personal injury and ensure safety 

operation and service of the Tester, please follow these guidelines:

•  Read the instruction before use and follow all safety instructions.

•  Use the Tester only as specified in the instruction card; otherwise, the Tester's safety 

features may not protect you.

•  Do not use the Tester and/or the accessory if they look damaged and / or wet.

•  Examine the case before you use the Tester. Look for cracks or missing plastic. 

Carefully look at the insulation around the terminals.

•  Do not use the Tester if it operates incorrectly.

•  Do not use the Tester just before, during or just after an electrical storm (electrical 

shock / high energy overvoltage!). Please make sure that your hands, your shoes, 

your clothing, the floor, switches and switching components are dry.

•  Never use the Tester if it just brought from a place with great temperature difference.

•  Do not use the Tester around explosive gas, vapor, or in damp or wet environment.

•  Limit operation to the specified measurement category, voltage, or amperage ratings 

between the terminals or between each terminal and earth ground.

•  Use extreme caution when working around bare conductors or bus bars. Contact with 

the conductor could result in electric shock.

•  Avoid to use the equipment in the environment with strong magnetic fields, strong 

electrostatic fields and strong RF fields.

•  Avoid simultaneous contact with battery and frame racks or hardware that may be 

grounded.

•  Comply with local and national safety codes. Use personal protective equipment 

(approved rubber gloves, face protection, and flame-resistant clothes) to prevent 

shock and arc blast injury where hazardous live conductors are exposed.

•  Do not touch voltages > 30 V ac rms, 42 V ac peak, or 60 V dc.

•  Keep fingers behind the finger guards on the probes.

•  Use only probes, clips, and adapters supplied with the Product.

•  Connect the common clip before the live clip and remove the live clip before the 

common clip.

•  Disable the Tester if it is damaged.

•  Only use probes, test clips, and accessories that have the same measurement 

category, voltage, and amperage ratings as the Tester.

•  Do not apply more than the rated voltage, between the terminals or between each 

Summary of Contents for AB70

Page 1: ...AB70 Manual...

Page 2: ...attery internal resistance and the discharge capability The Tester have overload protection bad contact indication revese polarity protection and etc Features of the tester include battery internal re...

Page 3: ...er 3 Tester Strurcture 3 Display 4 Push Buttons 5 Operating the Meter 6 A Test Battery Internal Resistance 6 B Test Battery Internal Resistance 8 C Maximum Load Test 10 D Engine Start Test 10 E Measur...

Page 4: ......

Page 5: ...nt Limit operation to the specified measurement category voltage or amperage ratings between the terminals or between each terminal and earth ground Use extreme caution when working around bare conduc...

Page 6: ...ource when the clips are connected to the current terminals Personal injury or damage to the equipment can occur if you attempt to make a measurement with a clip in an incorrect terminal A Warning sta...

Page 7: ...Page The Tester Tester Structure 1 Process Indicators 5 Battery Clips 2 Display 6 Temperature Probe Input Jack AB70B only 3 Push Button 7 USB Power Socket 4 Holster 8 LED Flashlight 6 7 8 1 2 3 4 5...

Page 8: ...ttery Type 2 Battery Standard 3 Analogue Bargraph 4 Testing Result 5 Steps Numbers State of Charge Battery Life 6 Battery Conditions SOC SOH STD TYPE PERFECT GOOD BAD REPLACE DISCHARGE STARTING CYL DU...

Page 9: ...ng on display after internal resistance test completed Press to switch to display between internal resistance state of charge voltage battery life current battery life Any Backlight Switch Press hold...

Page 10: ...battery voltage is lower than 8V Please fully charge the battery before test If the battery power is not enough charge the battery before test Recommended to charge 10 more minutes after the battery...

Page 11: ...ear The Testing Result area will also display the progress from 9 to 1 Please wait for the result 15 After the test is completed battery data will be shown 16 Press or to switch the display between in...

Page 12: ...320 150 755 26 330 200 995 Table A1 Note If the battery parameters cannot be found please refer to table A1 to set the discharge current B Test Charging System Warning Make sure the car brake is not...

Page 13: ...V for 24V battery check the drive belt and the wires conditions Test Results 12V Battery need to press the accelarator Engine Conditions Battery Voltage When headlamps air conditions are switch off Wh...

Page 14: ...ct this function 5 Press to start the test The testing period is 90s Within this time increase the engine speed to 2500 3000rpm 6 After the test is completed the test result Charging Voltage and state...

Page 15: ...if voltage 10 7V Please refer to the following table if voltage is 10 7V For 24V battery system the system is in good condition if voltage 17 5V Please refer to the following table if voltage is 17 5...

Page 16: ...ct this function 4 Press to start the test The testing period is 90s 5 Connect k type temperature probe to the Tester 6 Place the temperature probe to the object being test 7 The measured temperature...

Page 17: ...ent Battery Life Analyse Battery Level Detection Start Capabiltiy Battery Quality Display Backlight Flashlight Temperature Measurement Car Starting Test Car Charging Capability Car Load Measurement Ov...

Page 18: ...ry is connected external battery will be needed Please connect to a type C USB power source Cleaning Caution To avoid damaging the equipment NEVER submerge them in water DO NOT use abrasive cleaners t...

Page 19: ...AB70 Series Manual Version 1 0 Copyright 2023 All Rights Reserved...

Page 20: ...FMA6AB700Sg 0010 23 05...