background image

 

6

Air 2 in 1 Combi Nailer SF5040E

                                                                                 

 

Only those fasteners specified under TECHNICAL DATA (see 1.1) may be used 

When filling the magazine, hold the tool so that the muzzle is not pointing towards the operator or any other person or animals. 

4.4 Handling the tool 

Pay attention to 

2-Special Reference-

of these operating instructions. 

Having checked that the fastener driving tool is functioning correctly, apply the tool to a work piece and actuate the trigger. 

Check whether the fastener has been driven into the work piece in accordance with the requirements. 

- if the fastener is protruding, increase the air pressure in increments of 0.6 bar, checking the result after each new adjustment; 

- if the fastener is driven into an excessive depth reduce the air pressure I increments of 0.6 bar until the result is satisfactory. 

You should endeavor in any event to work with the lowest possible air pressure. This will give you three significant advantages; 

  1.energy will be saved, 2.less noise will be produced,    3.a reduction in fastener driving tool wear will be achieved. 

Avoid triggering the fastener driving tool if the magazine is empty. 

Any defective or improperly functioning fastener driving tool must immediately be disconnected from the compressed air 

supply and passed to a specialist for inspection. 

In  the  event  of  longer  breaks  in  work  or  at  the  end  of  the  working  shift,  disconnect  the  tool  from  the  compressed  air 

supply and it is recommended to empty the magazine. 

The compressed air connectors of the fastener driving tool and the hoses should be protected against contamination, the 

ingress of coarse dust chips, sand etc, will result in leaks and damage to the fastener driving tool and the couplings. 

DANGER! Potential hazard that could result in serious injury or loss of life 

Disconnect the tool from the compressed air source before loading fasteners. 

Do not point the tool towards the operator or other people while changing fasteners. 

Do not hold the tool with the trigger depressed while changing the fasteners. Failure to comply will lead to serious 

injury or loss of life. 

WARNING! 

Potential hazard that could result in serious injury or loss of life.

 

CAUTION! 

Potential hazard that may result in moderate injury or damage to equipment. 

Operate the tool with the utmost care when connected with the air compressor. 

Failure to comply may result in moderate injury or damage to equipment. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for SF5040E

Page 1: ...if effective hearing protection is not worn Health defects resulting from vibration emission if the power tool is being used over longer period of time or not adequately managed and properly maintain...

Page 2: ...ut the tool PERSONAL SAFETY These precautions are intended for the personal safety of the user and others working with the user please take time to read and understand them DANGER Potential hazard tha...

Page 3: ...r in an elevated position that could allow the unit to fall or be tipped over Always replace a damaged gauge before operating the unit again CAUTION Potential hazard that may result in moderate injury...

Page 4: ...rown staples 5 8 1 5 8 If feature a die cast aluminum housing and a comfortable handle for optimal control and comfort even during extended use It is well balanced for stability and ergonomically desi...

Page 5: ...an existing fastener Failure to comply could lead to serious injury or loss of life TYPES OF FASTENERS Please see the TECHNICAL SPECIFIACTIONS WARNING Potential hazard that could result in serious in...

Page 6: ...tool if the magazine is empty Any defective or improperly functioning fastener driving tool must immediately be disconnected from the compressed air supply and passed to a specialist for inspection I...

Page 7: ...efore making any adjustments Repairs must be performed by a qualified service technician only SYMPTOM PROBLEM SOLUTIONS Air leak near top of tool or in trigger area 1 O ring in trigger valve are damag...

Page 8: ...ety Stand Rectangle Seal Trigger Valve Guide Compressed Spring Trigger Valve Stem Pin 2 5 1 5 Trigger Valve Seat O ring 11 2 2 Compressed Spring Pin 2 5 16 Safety Space Trigger Bolt M4 10 Spring Washe...

Reviews: