51
6. Default settings
There are three default values available:
● High capacity mode (e.g. L.CAPA.)…….......for large tanks;
● Medium capacity mode (e.g. M.CAPA.)…....for medium tanks;
● Low capacity mode (e.g. S.CAPA.)………....for small tanks.
7. Manual regeneration
Press and hold „ ” key for 5 seconds to unlock the screen.
Press and hold the “■” key for 5 seconds while valve in standby condition to access the manual regen-
eration interface:
(1) If ‘DELAY’ is chosen and „ ” is pressed to exit the menu, valve shall commence regeneration when
regeneration time is reached (factory value 02:00).
Note: Regeneration model “METER IMMEDIATE” has no “DELAY” option
(2) If “IMMEDIATE“ is chosen and “ ” is pressed to exit the menu, the valve shall commence regenera-
tion immediately.
When regeneration starts, the screen displays:
XX REMAIN blinks on the screen. When valve reaches the BACKWASH position, display is permanent
during the process, except for the minutes the blink during the BACKWASH cycle. Push any key in
order to advance the valve to the next cycle (BRINE).
The screen displays:
Valve advances to subsequent regeneration cycles (RINSE and REFILL)
same as before.
8. Softened water adjustment (Optional)
Users may set desired hardness by operating the
mixture valve (Fig. 2).
Method:
Rotate the mixture valve clockwise.
The more the valve is rotated, the more hardness
value shall increase.
MAN.REG.
DELAY
MAN.REG.
IMMEDIAT
BACKWASH
XX REMAIN
BRINE
XX REMAIN
Mixture
valve
Summary of Contents for aquaPUR MIX 25
Page 107: ...107 2 2 1 2 2 1 4 100 12 1 4 2 3 12 99 5 NaCl 2 4 2 5 service bypass 3 5 12 12 22...
Page 122: ...122 4 4 4 09 00 CC 07 09 00 MI 01 12T 09 00 MD 01 12T 09 00 MO 01 12T...
Page 125: ...125 4 5 1 1 1 2 2 3 3 3 4 4 5 5 2 1 1 2 2 3 3 4 4 5 5 3 6 6 4 7 7 6 8 8 3 1 1 2 2 Valrom 3 3...
Page 126: ...126 4 1 1 2 2 5 1 1 2 2 3 3 6 4 4 5 5 7 6 1 1 2 2 3 3 4 4 1 4 5 5 6 6 7 1 1 2 2 3 3 4 4 5 5 A...