background image

Important Safety Notice

READ AND SAVE THESE INSTRUCTIONS

2

WARNING 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. 

WARNING 

TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 

a.  Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. 
b.  Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally. 

When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service
panel.

CAUTION

For general ventilating use only. Do not use to exhaust hazardous or explosive materials  and vapors.  Take care when using cleaning
agents or detergents. Suitable for use in household cooking area. 

WARNING 

TO REDUCE THE RISK OF RANGE TOP GREASE FIRE: 

a.  Never leave surface units unattended at high settings.  Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly 

on low or medium settings. 

b.  Always turn hood ON when cooking at high heat or when fl aming food   
c.  Clean ventilating fans frequently.  Grease should not be allowed to accumulate on fan or fi lter. 
d.  Use proper pan size.  Always use cookware appropriate for the size of the surface element. 
e.  Keep fan, fi lters and grease laden surfaces clean. 
f.  Use high setting on hood only when necessary. 
g.  Don’t leave hood unattended when cooking. 
h.  Always use cookware and utensils appropriate for the type of and amount of food being prepared. 

WARNING 

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING: 

a.  SMOTHER FLAMES with a close-fi tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. 

If the fl ames do not go out  immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.  

b.  NEVER PICK UP A FLAMING PAN – You may be burned.  
c.  DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d.  Use an extinguisher ONLY if:

1.  You know you have a Class ABC extinguisher, and you already know how to operate it.
2.  The fi re is small and contained in the area where it started.
3.  The fi re department is being called.
4.  You can fi ght the fi re with your back to an exit

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a.  Installation work and electrical wiring must be done by qualifi ed person(s) in accordance with all applicable codes and standards. 

Including fi re-rated construction.

b.  Suffi cient air is needed for power combustion and exhausting of gases through the fl ue (chimney) of fuel burning equipment to prevent 

back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National
Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and
the local code authorities.

c.  When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d.  Ducted fans must always vent to the outdoors.
e.  NEVER place a switch where it can be reached from a tub or shower.
f.  Make sure the power is off before installing, wiring or maintenancing.

Summary of Contents for VLA-E30AS

Page 1: ...Use Care and Installation Guide Model number Serial Number Lateral Wall VLA E30AS VLA E36AS JUN11 0101...

Page 2: ......

Page 3: ...Height Clearance 6 Ducting Options 7 Hood Specifications 8 Mounting the Hood 9 Ductless Recirculating 10 FEATURES CONTROLS Electronic Controls 11 MAINTENANCE Hood and Filter Cleaning 12 Light Bulbs 13...

Page 4: ...of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or me...

Page 5: ...is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes...

Page 6: ...s Extension duct cover accessory V1C 00LA Recirculating kit accessory VRC 00LA HARDWARE PACKAGE CONTENTS 1 Suction Cup PARTS SUPPLIED MODELS VLA E30AS VLA E36AS 1 Hood with internal blower 1 Duct cove...

Page 7: ...ent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round ro...

Page 8: ...performance and efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differe...

Page 9: ...e unless using the recirculating option Use single wall rigid metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting O...

Page 10: ...od Specifi cation 6 CL 29 15 16 35 7 16 14 1 8 2 13 16 20 1 16 STANDARD min ducted 26 min recirc 31 max 53 V1C 00LA EXTENSION min ducted 42 min recirc 46 max 80 11 7 1 16 9 7 16 10 9 16 2 3 16 3 9 16...

Page 11: ...just below the ceiling or soffit using 2 M6 x 1 screws FIG A 3 10 Install duct work and seal with aluminum duct tape Re install junction box with cable lock and install the electrical FIG B 2 11 Power...

Page 12: ...usted from cooking for re circulation RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED Kit includes charcoal filters charcoal filter brackets and air diverter plate Hood Models Part No Filters Bracket...

Page 13: ...Blower Speed Selection 2 Delay Off Timer 4 Blower On Off Press to turn blower on and off If lights are on they will also switch off when this button is pressed Press to cycle through light levels Brig...

Page 14: ...otton cloth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Aluminum Mesh Filters The aluminum mesh filters installed by the factory are intended to fil...

Page 15: ...by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach the included glass suction cup or...

Page 16: ...e defective part The unit is vibrating 1 The motor is not secured in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the insta...

Page 17: ...15 Wiring Diagrams...

Page 18: ...ght Bulb GU 10 50W each Z0B 0020 Optional Accessories Recirculating Kit VRC 00LA Replacement Charcoal Filters Qty 2 V0F C002 Extension Duct Cover V1C 00LA Order replacement parts from us by calling 1...

Page 19: ...labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE F...

Reviews: