6. OPERATING THE STOVE
Pre-lighting checks.
Ensure all the building work and flue sealing is complete.
Ensure the deflector plate is fitted correctly.
Ensure all the coals are correctly placed.
Ensure that the stove door is closed and secured.
Ensure that the stove door is completely sealed.
Lighting the burner.
If closed
,
open the isolating valve at the inlet elbow.
Depress the control knob and rotate it SLOWLY anticlockwise to the pilot ignition
position. A 'click' will be heard as the
integral piezo operates.
Turn the control knob clockwise to
the 'Off' position. Repeat this operation
until a flame appears at the pilot. The
pilot can be seen by looking through the
gap in the fuel effect (See figure 10).
There may be a delay before the pilot
lights due to air being purged from the
system. When a flame appears at the
pilot keep the control knob depressed
and hold the pilot ignition position for five
seconds. When the control knob is
released the pilot flame should remain lit.
Operating the burner.
When the pilot burner is operating properly, gradually turn the control knob anti-
clockwise to 'HIGH' (Depress the knob slightly to get past the pilot ignition position).
The main burner should now light. Depress the control knob slightly to release from
the 'HIGH' position and turn back (clockwise) to 'LOW'. While turning, the burner
flames should gradually become lower but remain alight. Depress the control knob
slightly to release from the 'LOW' position and turn back (clockwise) to the ‘Pilot
ignition’ position. The main burner should extinguish but the pilot should remain alight.
Depress the control knob slightly and turn back (clockwise) to turn OFF. This will
extinguish the pilot.
Page 15
©
Baxi Heating U.K. Limited 2010.
Figure 10.
INSTALLER GUIDE