Propane gas.
Propane gas appliances must not be installed in a cellar, basement or other room
which is built entirely below ground level (See Gas Safety (Installation and use)
Regulations).
Gas connection.
A nut and olive are provided for an 8mm pipe inlet connection to the elbow at the
bottom front of the appliance. The elbow can be rotated to allow a connection from
any direction. The elbow includes a valve for isolating the gas supply.
The supply pipe must be rigid material. Flexible pipe must not be used.
Note: Prior to connecting the gas supply it is advisable to blow out the gas
supply so that any dirt which may be present in the pipe is cleared and cannot
enter the gas valve or pilot burner and so cause a blockage.
With the supply connected pressure check the installation pipework for gas
soundness. In the United Kingdom check in accordance with the current edition of
BS6891. In the Republic of Ireland check in accordance with the rules in force.
Fitting the control knob.
Locate the control knob spindle
extension onto the gas tap spindle as in
figure 9 ensuring that the ‘D’ form and
screw are aligned. Secure in place with
the screw.
Locate the control knob onto the
control knob spindle extension ensuring
that the ‘D’ forms are aligned.
Fitting the ceramic fuel effect.
The installer and owner guide for the
ceramic fuel effect is supplied with the
ceramic fuel effect. It is important that the
installer guide for the ceramic fuel effect be placed inside or attached to this guide
and handed to the customer following completion of the ‘Final review and servicing’
section.
Page 14
©
Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE
Figure 9.