![Valor Ultimate Turbochim BR517S Installer'S Manual Download Page 4](http://html1.mh-extra.com/html/valor/ultimate-turbochim-br517s/ultimate-turbochim-br517s_installers-manual_3284036004.webp)
4
This product uses fuel effect pieces. It makes sense to take care when handling
these articles to ensure that the release of dust is kept to a minimum
.
This appliance does not contain any component manufactured from asbestos or
asbestos related products.
The appliance data label and wiring diagram are on a tie below the burner and
are visible when the bottom front cover is removed.
Gas
Natural (G20)
Propane (G31)*
Inlet Pressure
20mbar
37mbar
Input - Max. (Gross)
6.0kW (20,500Btu/h)
6.1kW (20,800Btu/h)
Input - Min. (Gross)
2.2kW (7,500Btu/h)
3.6kW (12,280Btu/h)
Output - Max.
3.12kW (10,600Btu/h)
3.6kW (12,280Btu/h)
Output - Min
1.1kW (3,750Btu/h)
1.8kW (6,140Btu/h)
Burner Test Pressure
(Cold)
18.2±0.75mbar
(7.3±0.3in w.g.)
35.6±0.75mbar
(14.3±0.3in w.g.)
Gas Connection
8mm pipe
8mm pipe
Burner Injector
Bray Cat. 18 Size 360
Bray Cat. 18 Size 170
Pilot & Atmosphere
Sensing Device
SIT Ref. OP9044
SIT Ref. OPLPG9222
Ignition
Piezo Electric. Integral
with Gas Tap
Piezo Electric. Integral
with Gas Tap
Aeration
Non-adjustable
Non-adjustable
Electrical supply
230V
~
50Hz AC
230V
~
50Hz AC
Fan motor rating
55W
55W
Fuse rating
3A
3A
*
When converted using kit 591149
P A R T 1 :
A P P L I A N C E D A T A