Vent Con
fi
gurations
10’
15’
20’
25’
30’
35’
40’
4’6”
5’0”
5’6”
6’0”
6’6”
7’0”
7’6”
8’0”
9’0”
10’0”
8’6”
9’6”
3” Liners
3” min. Bend
Radius
V
e
rtical V
e
nt
Height
Allowable Horizontal Offset
10’
min.
- 40‘ max.
559CLT
Co-Linear Terminal
See
Chart
559CLT
Termination
3” Inlet & Exhaust
Collars (exhaust collar
is slighthly longer)
10”
10”
Allowable Vent Confi gurations
The RF24 is certi
fi
ed for use with approved 3” diameter
fl
exible venting installed into an approved existing solid
fuel burning masonry or factory built chimney system.
The venting system must terminate vertically at the
roof using an approved termination cap. Both inlet and
exhaust liners must be run continuously from appliance
to roof termination.
Where possible, avoid joints in
fl
ex pipe. If joints
are required, use only connectors approved by the
manufacturer of the
fl
ex pipe. Field fabricated joints are
not allowed.
Any generic 3” diameter
fl
exible venting
approved
for venting gas appliances
is acceptable. See list of
the approved venting components on page 27 of this
manual.
WARNING
Failure to position the parts in
Failure to position the parts in
accordance with these diagrams or
accordance with these diagrams or
failure to use only parts speci
fi
cally
failure to use only parts speci
fi
cally
approved with this appliance
approved with this appliance
may result in property damage or
may result in property damage or
personal injury.
personal injury.