17
Speci
fi
cations
Approvals and Codes
This appliance is certi
fi
ed to ANSI Z21.88–2014/CSA
2.33–2014 American National Standard/CSA Standard
for
Vented Gas Fireplace Heaters
for use in Canada
and USA.
The appliance complies with CSA P4.1-09,
Testing
method for measuring annual fi replace effi ciencies
.
The installation must conform with local codes or, in
the absence of local codes with the
National Fuel Gas
Code
, ANSI Z223.1or the
Natural Gas and Propane
Installation Code
CAN/CGA-B149. Only quali
fi
ed
licensed or trained personnel should install the
appliance.
The appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the
National Electrical
Code
, ANSI/NFPA 70 or the
Canadian Electrical Code
,
CSA C22.1.
Ratings
*Tested to CGA - 2.17-91
Gas fi red appliances for use
at high altitudes
. In USA, installations may require
deration over 2000’ —Check local codes.
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certi
fi
ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas utility
to con
fi
rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Supply Gas
Heater engine 530ILN/ICN/IRN is used for natural gas
installations.
Heater engine 530ILP/ICP/IRP is used for propane gas
installations.
The supply pressure must be between the limits shown
in the
Ratings
table on the previous page.
The supply connection is 3/8 inch NPT female located
at the left side of the control valve.
The opening for the gas supply line is at the rear left
corner of the appliance.
Fuel Beds
The 530I engine is available in either natural gas or
propane gas and comes equipped with either a simu-
lated logs, coals, or rocks fuel bed in either fuel.
Electrical
The unit does not require an electrical power source
unless
fi
tted with an optional circulating fan.
Floor/Hearth
This appliance is approved for installation directly on
combustible material such as plywood and so on. Vinyl,
carpet, and soft
fl
ooring require sheet metal extending
the whole width and depth under the appliance. This
appliance does not require a hearth. Combustible
fl
ooring may extend up to the front of the unit.
Front Trims/Stove
Various fronts are available for the 530I engine. This
engine may be installed as a free standing, zero
clearance or insert application depending on which
style front trim is selected.
The front trim/stove
style affects the framing cavity, clearances and
position of the engine. A front trim kit is required
for all applications and should be on site when
the engine is installed
as the parts to make the
engine suitable for zero clearance are supplied with the
front trim kits (except 549 front).
Gas supply connection
3/8” NPT female at valve
Gas line
access at
rear left
corner
Model NG
LPG
Gas
natural
propane
Altitude (ft)*
0-4 500 pieds*
Input max. (Btu/h)
20,500
19,000
Input min. (Btu/h)
6,500
12,500
Manifold pressure (in w.c.)
3.5–3.9
10.3–10.7
Min. supply pressure (in w.c.)
5
11
Max. supply pressure (in w.c.)
10.5
14
Main burner injector (no.)
580
200
Pilot injector (no)
35
27
Min. by-pass screw
125
125