State of California. Proposition 65 Warning. 

Fuels used in gas, wood-burning or oil fired appliances, and the 

products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth 

defects and other reproductive harm. California Health & Safety Code Sec. 25249.6.

State of Massachusetts Carbon Monoxide Detector/Vent Terminal Signage Requirements

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used 

in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where 

the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, 

including but not limited to decks and porches, the following requirements shall be satisfied: 

1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal 

vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide 

detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. 

In addition, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide 

detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side 

wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the 

services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, 

the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor 

level.

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the 

owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during 

said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance 

with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. 

3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at 

a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally 

vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch 

in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not 

approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage 

installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4. 

(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4: 

1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of 

NFPA 54 as adopted by the Board; and 

2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate 

from the dwelling, building or structure used in whole or in part for residential purposes. 

Safety and Warning Information

Summary of Contents for Portrait 530ICN/ICP

Page 1: ...ion Operating Instructions Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation and service must be performed by a qualified i...

Page 2: ...uld you encounter an operational problem call your dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation ma...

Page 3: ...ns 13 Vertical Termination Installations 15 Appliance Preparation 16 Air Restrictors Installation 19 Gas Supply Installation 20 Aeration Setting Check 21 Ceramic Walls Installation 21 Ceramic Logs Ins...

Page 4: ...lation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate soli...

Page 5: ...pment is installed in a crawl space or an attic the hard wired carbon monoxide detector with alarm and battery back up may be installed on the next adjacent floor level b In the event that the require...

Page 6: ...de wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements shall be satisfied by the manuf...

Page 7: ...cations and should be on site when the engine is installed as the parts to make the engine suitable for zero clearance are supplied with the front trim kits except 549 front Fuel Beds The 530I engine...

Page 8: ...supply pressure must be between the limits shown in the Ratings table on the previous page The supply connection is 3 8 NPT female The opening for the gas supply line is at the rear left corner of the...

Page 9: ...prevent condensation on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18 46 E Cle...

Page 10: ...ard may be required if terminating within 7 0 of grade or where accessible In Corner No Vertical Rise Maximum 1 x 45 elbow allowed Maximum 18 horizontal pipe length Terminal guard may be required if t...

Page 11: ...es 32 33 for allowable components 14 36 cm max combustible wall 530 engine Top Outlet w Vertical Rise Horizontal Termination See Conversion to Top Outlet for Solid Direct Vent Co axial Piping in Appli...

Page 12: ...rough the outer tube and the appliance collar with 6 screws Make sure the drill does not penetrate the inner pipe Secure the vent unit or 817VAK to the outer collar with two 6 thread cutting screws su...

Page 13: ...depending on the particular installation 1 5 16 33 mm min clearance to combustible materials all round 40 12 2 m max Total offset 4 6 137 cm max Ceiling firestop Roof flashing Approved vertical termi...

Page 14: ...y systems no combustible construction The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Flashing 2 x 3 liners 24 1 2 3 min bend radius Co linear ada...

Page 15: ...ter Place the appliance in its proper location Drop a plumb from the ceiling to the center of the appliance vent opening Mark the position on the ceiling Drill a small hole at the marked position Dete...

Page 16: ...orizontal run as shown on page 14 in this manual Fit the termination kit and flashing if required to the exterior of the chimney Secure the appliance to the floor or wall if necessary 1 Vertical Termi...

Page 17: ...inner vent collar and seal by unscrewing 8 screws To make sure that the collars are axially aligned fit the adapter 817VAK over the outer vent collar Position the inner collar and seal vertically ins...

Page 18: ...the adapter to the outer collar with two 6 thread cutting screws supplied 1 1 Co linear Conversion using Valor 556CLA Co linear Adapter Note Instructions may vary as 556CLA may be installed on Top or...

Page 19: ...e restrictors remove the center screws from the rear ports and fit the restrictors using these screws To set the restrictors at maximum port opening slacken the bottom screws in the ports slide the re...

Page 20: ...s The supply line should include a manual shut off valve and union to allow the appliance to be disconnected for servicing Pressure test the supply line for leaks The appliance and its individual shut...

Page 21: ...on in this manual for adjustment details The shutter setting is very critical A change of 1 64 can make a substantial difference to the performance Ceramic Walls Installation The 530 engine is provid...

Page 22: ...base log Locate the left side log on the ceramic pin on the left hand side of the base log Rest the narrow nose of this log on the projection at the front center of the base log ensure that the narrow...

Page 23: ...ace the right front coal behind the metal lip at the front of the firebox Its left side should rest over the projection on the left front coal The center right coal has letter R embossed underneath Pl...

Page 24: ...the window seal 1 Initial Remote Control Set up The receiver and the handset of the remote control system must be initially synchronized before the first use Insert batteries in the remote control re...

Page 25: ...dust and lint to cling to the glass surface Initially paint while curing may deposit a slight film on the glass We therefore recommend that during the first few weeks of use the glass be cleaned two o...

Page 26: ...aflet Please always quote part number and description when requesting spare parts Thermocouple probe must be in flame Correct flame appearance With Logs With Coals Your fireplace remote control helps...

Page 27: ...ime Setback temperature timer TIMER MODE appliance must be in Standby mode pilot ignited The Timer setting allows you to set two burner ON times and two burner OFF times for every 24 hour period Chang...

Page 28: ...check the tempera ture every five minutes adjusting the amount of fuel needed to give you a steady even heat The display must remain in TEMP mode on the remote handset 1 Timer It is possible to progr...

Page 29: ...y needs to be replaced Replace with one 9 V battery alkaline recommended Receiver Three short beeps will sound when the motor turns when the batteries need to be replaced Replace with four 1 5 V batte...

Page 30: ...step 3 AUTOMATIC IGNITION Fig 1 Locate the pilot Fig 3 inside of firebox at left hand side ON OFF switch 1 in ON position MAN knob 2 in ON position set Flame Adjustment knob 3 to lowest setting On th...

Page 31: ...a wall switch Circulating Fan Kit 555CFK Having variable speed and temperature control it is designed to boost the natural convection process through the appliance It may be fitted before the fireplac...

Page 32: ...o axial 46DVA VCE Co linear 3PDVCV HS C33U 99 559CLT HS C33F 1313 Snorkel 14 Rise 46DVA SNK14 4DT ST14 Snorkel 36 Rise 46DVA SNK36 4DT ST36 Vent Adapters Couplers Universal Adapter 3 Flex Coupler 2150...

Page 33: ...8 SV4L48 Black 46DVA 48B 4DT 48 B SV4LB48 Flashings Roof Flashing 46DVA F6 4DT AF6 SV4FA Roof Flashing 46DVA F12 4DT AF12 SV4B Flat Roof Flashing 46DVA FF SV4F Various Venting System Parts Wall Thimbl...

Page 34: ...other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards This warranty does not cover glass log br...

Page 35: ...tor plate 1 logs 320B396 45 Remote receiver 4001911 17 Restrictor plate 2 logs 320B397 46 Hand held control 4001910 18 Restrictor plate 3 logs 320B405 47 Wall mount plate 9000008 19 Window unit 050A21...

Page 36: ...8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 33 32 34 35 36 37 37a 37b 38 39 40 41 42 43 44 43a 45 46 47 48 42a 41a 41b NG LPG 50 51 52 53 54 55 56 57 58 59 60 61 62 49 Repla...

Reviews: