Valor LINEAR SERIES Installation And Operating Instructions Manual Download Page 3

3

Remove screw

Lift burner module out of 

fi rebox

Rotate fan into position

Remove burner from 

fi rebox

Install the fan

To gain access to the fan area

1.  Remove the screw at right end of burner.

2.  Slide burner to the right to disengage it from the 

orifi ce and lift it out of the fi rebox.

3.  Remove the screw maintaining the air defl ector to 

the appliance bottom panel. Then, remove the 10 
screws around the perimeter of the burner module 
plate.

4.  Rotate the rear edge of the burner module upwards 

and remove the module plate from the fi rebox.

To install the fan

1. 

Insert the fan through the opening in the fl oor of the 

fi rebox and rotate into position.

1700J and 1800J appliances: 

Remove the plate 

to the right of the opening to access fi xing points 
for the fan (4 screws).

Remove 1 screw holding air defl ector and 
10 screws holding burner plate

Remove fan fi xing access plate (4 screws)

Summary of Contents for LINEAR SERIES

Page 1: ...supplied by electrician These instructions cover the installation of the fan unit only For instruc tions regarding how and where to locate the power outlet within the fireplace casing refer to instru...

Page 2: ...lled inside the appliance case to complete the fan installation Test the fan It may be desireable to test the fan operation before reassembling the burner module and completeing the fireplace installa...

Page 3: ...he appliance bottom panel Then remove the 10 screws around the perimeter of the burner module plate 4 Rotate the rear edge of the burner module upwards and remove the module plate from the firebox To...

Page 4: ...e heater Apply label to base next to fan Receptacle in lower right corner of liner box 2 Line up the slotted holes in the fan mounting plate with the holes in the base of the liner box and fasten usin...

Page 5: ...ransportation of defective parts or 3 incidental or consequential damages THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE WARRANTY OF MERCHANTABILITY OF F...

Page 6: ...llume Quand le foyer s teint le ventilateur continue de fonctionner temporaire ment jusqu ce que l interrupteur thermique refroidisse Note Lorsque le foyer fonctionne en bas r gime il est possible que...

Page 7: ...plateforme du milieu avant et arri re D branchez l alimentation de gaz de l appareil la soupape NOTE Le c blage lectrique doit tre d j install dans la caisse du foyer pour compl ter l installation du...

Page 8: ...10 vis retenant la plaque du module du br leur la bo te de foyer 4 Pivotez le bord arri re du module vers le haut et tirez le hors de la bo te de foyer Pour installer le ventilateur 1 Ins rez le vent...

Page 9: ...T POUR CE VENTILATEUR ET NE DEVRAIT TRE REMPLAC QU AVEC DES PI CES ORIGINALES FOURNIES PAR LE FABRICANT MOD LE 1595CFK VENTILATEUR DE CIRCULATION D 120 V CA 60 Hz MOINS DE 1 A FABRIQU PAR MILES INDUST...

Page 10: ...T LES GARANTIES DE QUALIT MARCHANDE OU D UTILISATION DE L APPAREIL DES FINS PARTICULI RES AINSI QUE TOUTES AUTRES OBLIGATIONS OU RESPONSABILIT S MILES INDUSTRIES LITD N ASSUME NI N AUTORISE AUCUNE PER...