Set and check manifold pressure and 
aeration

Set the manifold pressure.
1.  Remove the valve access panel (5 screws) on the 

left hand side of the appliance case. If the appliance 
is already installed, you will need to pull the left 
hand side out of the cavity.

2.  Fit a manometer to the 

manifold pressure test 
tap on the valve—see 

fi

 gure at right. 

3.  Light the appliance and 

turn the control to full 
input. 

4.  Adjust the pressure 

adjustment screw using 
a small jeweller’s size 

fl

 at 

blade screwdriver—as 
shown below—while 
the appliance is running 
at full input to produce 
manifold pressure, as per 

Speci

fi

 cations 

table on page 1.

Manifold Pressure 
Test Tap

Valve Inlet 
Pressure

Loosen screw to check 

(tighten afterwards)

Pressure Test Tappings

Front Face of 
Control Valve

Pry off 
plastic cap

Front Face of 
Control Valve

Pressure
adjustment
screw behind
plastic cap

Increases pressure

Decreases pressure

5.  Check the aeration and adjust the air shutter if 

necessary.

6.  Turn off the appliance, remove the manometer and 

tighten the test tapping screw. Check for leaks.

7.  Fit the label 

“This control has been converted...”

 on 

the left hand side of the appliance near the valve.

8. Re

fi

 t the valve access panel (5 screws).

Add baf

fl

 e to rear log support 

(when 

converting to 

LPG only

)

Fix the secondary air baf

fl

 e provided to the underside 

of the rear log support with 4 screws provided as 
indicated. The baf

fl

 e can also be riveted to the support 

from the top.

0B293

6 mm

AERATION GAP

Flashback 

shield

LPG Air Shutter 

Slider

Open

Close

LPG

Open

Open

Close

Close

NG

NG Air Shutter 

Slider & Cover

6 mm

Valve

3

Summary of Contents for Legend G4 Series

Page 1: ...ver to set pressure Small flat blade screwdriver to release pressure tap on valve Nut driver 8 mm or 5 16 to remove burner nuts Needle nose pliers to remove by pass screw Hex Allen wrench 4 mm or 5 32...

Page 2: ...brackets from the burner by removing 2 nuts using a 5 16 8 mm wrench 4 Transfer the burner support brackets to the new conversion burner securing them with the 2 nuts removed in step 3 Note do not ove...

Page 3: ...ck tighten afterwards Pressure Test Tappings Front Face of Control Valve Pry off plastic cap Front Face of Control Valve Pressure adjustment screw behind plastic cap Increases pressure Decreases press...

Page 4: ...plied with the appliance 1 Refit the ceramic panels first then the front brick support and the rear log support 3 screws 2 Reinstall the grate with logs only the fuel bed the window the front trim and...

Page 5: ...la pression sur la soupape Nut driver 8 mm or 5 16 to remove burner nuts Pince bec effil pour enlever la vis d incice Cl hexagonale Allen de 4 mm ou 5 32 pour enlever l injecteur de la veilleuse Mano...

Page 6: ...enlevant deux crous l aide d une cl de 5 16 8 mm 4 Installez les supports de br leur sur le br leur de conversion en r utilisant les deux crous enlev s l tape 3 Note Ne serrez pas trop les crous pour...

Page 7: ...evez le manom tre et serrez la vis de v rification de pression V rifiez tous les raccords pour voir s il y a des fuites 7 Fixez l tiquette Cette commande a t convertie pr s de la soupape 8 R installez...

Page 8: ...neaux de c ramique le support de briques avant et ensuite le support de b che arri re 3 vis 2 R installez le porte b ches avec b ches seulement les b ches ou pierres la fen tre la bordure et la porte...