Valor LEGEND G4 785XN Installation And Owner'S Manual Download Page 29

Install Driftwood Kit 1101DWK

Material required

•  Long Beach Driftwood Kit, which contains:

• 

3 logs

• 

5 pebbles

• 

1 x 1.5 lb bag of 3/4” grey/black shale

•  Gloves, if desired

Installation

Logs

Carefully unpack the kit.
Each log has pegs to help you locate them on the 
ceramic burner platform. Install the logs as shown 
below.
1.  Place the left log on the left side of the ceramic 

burner inserting the two pegs of the log in the holes 
of the burner. NOTE: There are two sets of holes for 
this log depending which type of gas is used for the 
appliance.

NG 

fi

 re:

 Place the log forward in the 

fi

 rebox for 

natural gas (NG) 

fi

 re.

LPG 

fi

 re:

 Place the log rearward in the 

fi

 rebox for 

propane gas (LPG) 

fi

 res.

2.  Place the right log on the right side of the ceramic 

burner inserting the two pegs of the log in the holes 
of the burner. The rear end of the log rests on the 
pilot shield. NOTE: There are two sets of holes for 
this log depending which type of gas is used for the 
appliance.

NG 

fi

 re:

 Place the log forward in the 

fi

 rebox for 

natural gas (NG) 

fi

 re.

LPG 

fi

 re:

 Place the log rearward in the 

fi

 rebox for 

propane gas (LPG) 

fi

 res.

3.  Place the center log inserting its front end peg in 

the hole in the front of the burner and resting its rear 
end in the slight depression on top of the left log.

Installation

LPG

NG

LPG

NG

29

QUALIFIED 
INSTALLER

Summary of Contents for LEGEND G4 785XN

Page 1: ...ible en fran ais sur demande This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used...

Page 2: ...e Remote Control 34 Check Operation 35 Adjust Aeration if needed 35 Install Side Shrouds 36 Install Front Trim and Barrier Screen 36 Install Handset Wall Holder 36 Wiring Diagram 37 Approved Venting C...

Page 3: ...BE PLACED on or near the appliance This unit MUST be used with a vent system as described in this installation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assemb...

Page 4: ...ace A physical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at...

Page 5: ...ied dealer Each Valor fireplace is fully tested during the production process for your safety and comfort Your unit has been professionally installed by Dealer Name ________________________________ Ph...

Page 6: ...lts from the products listed below We cannot however guarantee the results of these products BRASSO POLISH PLUS by KELKEM COOK TOP CLEAN CREME by ELCO WHITE OFF by RUTLAND TURTLE WAX Do not clean the...

Page 7: ...angerous conditions Damage caused by incorrect window installa tion is not covered by the Valor warranty DANGER The window unit must be correctly installed fastened and sealed after servicing or serio...

Page 8: ...ILL HOT Let the fireplace cool first before touching it Wall Switch optional Thermostatic Remote Control Manual On Off Switch WARNING Battery box The appliance area must always be kept clear and free...

Page 9: ...OFF Switch Remote control handset Wall Switch optional OFF ON ON parallel to pipe OFF perpendicular to pipe Owner s Information How to Ensure Your Fireplace Cannot Be Turned ON Inadvertently You can u...

Page 10: ...t NOTE Before using the remote control system for the first time the receiver and the handset must be synchronized See the section Remote Control Initial Set up on page 34 of this manual Set scrolls t...

Page 11: ...ersa The time display will flash after either Installing the battery or Simultaneously pressing the large flame and small flame buttons Press large flame button to set the hour Press small flame butto...

Page 12: ...r NOTE The display shows the set temperature every 30 seconds NOTE 8 seconds after the fan has been set the handset will automatically go into temperature control mode The fan starts 4 minutes after t...

Page 13: ...pm in each 24 hour cycle The Programs P1 and P2 must be set in the following order during a 24 hour cycle and The icon indicates the beginning of the period ON and the icon indicates the end of the p...

Page 14: ...no communication between the receiver and the handset for a period of 6 hours the appliance goes into pilot mode No change in flame height If there is no change in flame height for a period of 6 hour...

Page 15: ...ood Kit 785XDGM Decorative Glass Murano 785XDGS Decorative Glass Set Liner Panels 786LSLV2 Ledgestone Liner Set 787RGL Reflective Glass Liner Set 788FBLV2 Fluted Black Liner Set 789VRLV2 Valor Red Bri...

Page 16: ...STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG VLGH ON OFF switch 1 in ON positio...

Page 17: ...ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 High Altitude Installations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4 500 feet 1 370 m ab...

Page 18: ...th as required for existing solid fuel burning fireplaces Combustible hearths or floors must be mininum 4 102 mm below bottom of heater Trim sold separately WARNING HOT HEARTH FLOOR The hearth or floo...

Page 19: ...el is combustible see following section for allowable clearances A hearth that is at a height within 4 102 mm of the bottom of the heater MUST be non combustible all trims except 799 Edgemont Door wit...

Page 20: ...Combustible Mantel Clearances Measure taken from the underside of the mantel to finished hearth or surface that the unit is sitting on Finishing Materials Combustible materials Material such as wood c...

Page 21: ...w hits the outside vent terminal from any direction Check local codes for allowable vertical vent termination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vert...

Page 22: ...points must be considered before inserting the 785 into an existing fireplace cavity Generally no modifications are allowed to the existing fireplace that will compromise the integrity of the existin...

Page 23: ...1 5 inch 38 mm or less through the lower sides or bottom of the firebox The access hole must be plugged with non combustible insulation after the gas supply line has been installed See Dimensions sec...

Page 24: ...before the appliance is fitted into the cavity Refer to instructions provided with the 795CFKV2 to install the fan Remove Window The window is held in place by a spring loaded lever on each side 1 To...

Page 25: ...ack of the firebox 3 Apply RTV sealant to the collars on the vent slider and fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure with 4 tapping...

Page 26: ...ment shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Failure to either disconnect or isolate the appliance during pre...

Page 27: ...es where local codes do not permit the flex connector to be used inside the appliance case reconnect the flex connector outside of the appliance case A cut out is provided in the appliance case for th...

Page 28: ...etaining lances Be careful not to hook the pilot hood as you pull the burner up 3 To reinstall the burner fit the burner in the firebox inserting the front tabs first in the lances Note Ensure that th...

Page 29: ...og forward in the firebox for natural gas NG fire LPG fire Place the log rearward in the firebox for propane gas LPG fires 2 Place the right log on the right side of the ceramic burner inserting the t...

Page 30: ...of shale pieces Pebbles Place the pebbles on the platform as shown below WARNING CHOKING HAZARD Ensure that the fireplace area is clear fireglass particles as these could be ingested by small childre...

Page 31: ...e front 3 Install the glass platform on top of the retainers 4 Carefully spread the glass on top of the burner within the platform opening 5 Install the square glass panel on top of the pilot shield N...

Page 32: ...er the pilot shield The lip on the top surface goes to the front 3 Carefully fill the metal tray with fireglass leveling it with the top of the tray s flange NOTE Ensure the pilot area is clear of gla...

Page 33: ...nents cause overheating resulting in dangerous conditions Damage caused by incorrect window installa tion is not covered by the Valor warranty DANGER The window unit must be correctly installed fasten...

Page 34: ...y box upside on the left of the firebox Battery box connection Reset button Battery box Remove cover Connect battery box to wire 5 With a sharp object press and hold the receiver s reset button until...

Page 35: ...cts glow Decreasing aeration will cause the flames to appear more yellow or orange showing less ceramic effects glow Too little aeration may result in black carbon forming on logs or roof panel and dr...

Page 36: ...Switch Plate Alternative 1 Alternative 2 Alternative 3 Install Handset Wall Holder The remote control kit for this fireplace comes complete with a wall mounted holder This holder is not required in al...

Page 37: ...Wiring Diagram Remote Battery Box Optional Fan 795CFKV2 Control Module Optional Wall Switch Kit 1265WSK Red Yellow 4 AA Batteries GV60 Wiring Diagram Connector 37 QUALIFIED INSTALLER...

Page 38: ...o axial Adapter 46DVA GK TM 4CTA 4DCAT33 Aluminum Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmaster and...

Page 39: ...mage to the unit due to i Improper installation operational or environmental conditions ii Inadequate ventilation in the area or competition for air from other household equipment or appliances iii Ch...

Page 40: ...tor 51 NG 4000735 Pilot Injector 30 LPG 4000736 35 Pilot Tube 4000732 36 Pilot Hood 2 Flame 4001756 37 Extended Nut 4001855 38 Electrode 4001856 39 Insulation sleeve for ignition cable 4002244 40 Inje...

Page 41: ...r red brick 4002385 72 Rear panel a Ledgestone 4004267 b Reflective Glass 4004707 b Rear filler panel 4004799 c Ceramic fluted black 4004268 d Valor red brick 4004266 73 Left side panel a Ledgestone 4...

Page 42: ...43 44 45 46 47 48 49 50 70 71 72 73 74 1 2 3 7 8 9 10 12 14 15 13 11 16 23 25 26 17 18 19 19 21 22 20 32 38a 42 40 41 27a 27b 29 9 39 51 52 53 54 55 55 56 57 58 59 60 65 66 67 61 62 63 64 63 42 OWNER...

Page 43: ...tion provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model...

Page 44: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...

Reviews: