27
Flashing
1 x 3”
intake
liner
and
1 x 4”
exhaust
liner
3” min. bend radius
for intake liner and
4” min. bend radius
for exhaust liner
3” intake
liner
4” exhaust
liner
46DVA-34CLAA
or 46DVA-GCL34
Co-linear
adapter
Engine
Approved 3 x 4
co-linear termination
Framed
wall
Clearances
to combustible
materials listed
elsewhere in this
manual apply
Flashing
1 x 3” intake liner
and
1 x 4” exhaust liner
Max. 12”
3” min. bend radius
for intake liner and
4” min. bend radius
for exhaust liner
3” intake
liner
4” exhaust
liner
46DVA-GCL34
or 46DVA-34CLAA
Co-linear
adapter
Engine
Approved 3 x 4
co-linear termination
Framed
wall
Clearances
to combustible
materials listed
elsewhere in this
manual apply
Installation using 46DVA-34CLAA
Installation using 46DVA-GCL34
Venting
Co-Linear Conversion
Note:
Co-linear
fl
exible aluminum venting should be
professionally inspected periodically for corrosion
and damage and replaced when necessary. If the
installation does not allow for future inspection or
replacement of the
fl
exible aluminum venting, then
stainless steel vent liners should be used.
Note:
Co-linear portion of vent system may only be
installed within a solid-fuel burning
fi
replace and
chimney.
Installation into existing adjacent chimney
The appliance can be adapted to co-linear applications
using an existing chimney. The appliance must not be
connected to a chimney
fl
ue serving a separate solid-
fuel burning appliance.
Requires the Co-Axial to Co-Linear appliance Adapter
46DVA-34CLAA or equivalent, two lengths of 2-ply
fl
exible chimney liner both approved for venting gas
appliances: one 3” diameter liner for intake and one 4”
diameter liner for exhaust, a 3 x 4 co-linear termination
kit and
fl
ashing.
The appliance must be fully enclosed while maintaining
clearances to combustibles detailed elsewhere in this
manual.
Rules for Co-Linear Venting
• Maximum 40 feet vertical pipe
• Minimum 10 feet vertical
• Maximum o
ff
set 8 feet with liners at minimum
45 degrees from horizontal plane
• Restrictor: Not required when using co-linear venting.