![Valor HORIZON 534JN Installation Manual Download Page 12](http://html2.mh-extra.com/html/valor/horizon-534jn/horizon-534jn_installation-manual_3646008012.webp)
12
Planning
Framing
• A non-combustible hearth is not necessary in front of
this appliance.
• Note that the appliance is installed at the framing
stage and secured to framing using support angles.
See page 24, 26. Wall
fi
nish is then installed
afterwards over the support angles and up to the
perimeter of the unit.
NOTE
When the appliance is installed directly on
carpeting, tile or other combustible material
other than wood flooring, the appliance shall be
installed on a metal or wood panel extending the
full width and depth of the appliance.
33-3/4” to
header
- 29-3/4” to wall finish
- 30-3/4” when using
645CFV Clearview Front or
673 Edgemont Front
See installation manual
packed with front trim
35-1/2”
Wall Finish
This is the framing
width. Wall finish
to 32-3/16” wide.
16” min. straight out or off the top venting.
Allow for elbow if rear vent with rise.