Co-Linear Vent Installations

••  The chimney and 

 replace opening sizes are shown in 

Dimensions

 and 

Location

 sections of this manual.

••  Place the appliance (

 tted with the co-linear adapter) 

near the 

 replace opening but allow space for 

manipulating the chimney liners on to the appliance.

••  Drop the 3-inch diameter 

 exible liners into the 

chimney from outside.

••  Fit the liners to the co-linear adapter paying attention to 

inlet and exhaust and move the appliance to its proper 
position. Be aware of the minimum liner bend radius 
and maximum liner horizontal run shown on page 16 of 
this manual.

••  Fit the termination kit and 

 ashing to the exterior of the 

chimney.

Secure the appliance to the 

 oor or wall if necessary. 

Rear or Top Outlet Conversion to Co-Linear Liners using Valor 
556CLA Co-Linear Adapter.

(Generic co-axial to co-linear adapter boxes may also be used as an 
alternate to the 556CLA).

Only for use when retro

fi

 tting a solid-fuel burning 

fi

 replace and chimney.

The appliance must not be connected to a chimney 

 ue serving a separate solid-

fuel burning appliance.
Requires 556CLA Co-Axial to Co-Linear Appliance Adapter (or, alternatively, a 
generic adapter), two lengths of 3-inch diameter 

 exible chimney liner, co-linear termination kit and 

 ashing and either 

high wind vertical vent terminal cap or a low pro

 le vertical termination. 

Zero Clearance stand-offs and shields supplied 

with the heater are not required for this application

.

Flashing

2 x 3”

liners

3” min.

bend radius

Co-linear

adapter

2 x 3”

liners

18” max.

horizontal run

Co-linear

adapter

534

engine

Max.
40’

Approved co-linear 

termination or approved 

co-linear adapter

and approved

co-axial

termination

 Co-Linear Venting

Co-Axial to Co-Linear Adapter 
(alternate to 556CLA)

10”

10”

3” Inlet & Exhaust

Collars

7-5/8” dia.

collar

556CLA

2 x 3” Liners

26-3/4”

14”

556CLA

2 x 3” Liners

26-3/4”

14”

556CLA on 

Rear Outlet

556CLA on

Top Outlet

Alternate to 559CLT/559FSK Conversion

559FSK Flashing Kit

559CLT Co-Linear Terminal

Co-Linear installation into existing F/P

556CLA Kit

Terminal Cap

Co-Linear to Co-Axial 

Adapter

Flashing

QUALIFIED 
INSTALLER

Summary of Contents for Horizon 534JLN

Page 1: ...of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used This appliance is a domestic room heating appliance It must not be used...

Page 2: ...O M F O R T V A LOR CO M F O R T Safety Precautions 3 Safety and Your Fireplace 4 Owner s Information 5 Remote Control Operation 9 Options 13 Lighting Instructions 14 Warranty 45 Commonwealth of Massa...

Page 3: ...and draperies Clothing or ammable material SHOULD NOT BE PLACED on or near the appliance Clothing or ammable material SHOULD NOT BE PLACED on or near the appliance This unit MUST be used with a vent...

Page 4: ...ce A physical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at...

Page 5: ...hearth or oor in front of the replace may become very hot in front of the replace may become very hot when the replace heats Do not use the hearth when the replace heats Do not use the hearth as a se...

Page 6: ...complete window unit as supplied by the manufacturer If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this appliance Owner s Information WARNING DO NOT...

Page 7: ...out from its location 2 Slide and remove the receiver cover 3 Replace batteries with 4 AA alkaline batteries 4 Replace the cover 5 Put the receiver back in its position pushing it in so it attaches to...

Page 8: ...rol Thermostatic Remote Control Wall Switch optional ON OFF Manual On Off Switch Lighting Operation and Rating Information The Lighting Operation and Rating information is located on a plate under the...

Page 9: ...e height NOTE Before using the remote control system for the first time the receiver and the handset must be synchronized See the section Remote Control Initial Set up on page 39 of this manual Set sc...

Page 10: ...ss small ame button to set the minute Press OFF or simply wait to return to MAN mode Double click large ame button Flame automatically goes to high re HI will be displayed Manual Mode Manual Flame Hei...

Page 11: ...e programming SETTING THE DAYTIME TEMPERATURE SETTING THE NIGHTTIME SETBACK TEMPERA TURE Default Settings sun 23 C 74 F Default Settings moon OFF Press large ame button to increase Nighttime Setback T...

Page 12: ...ll to TIMER moon while the time ashes Press large ame button to set the hour Press large ame button to set the hour Press small ame button to set the minutes Press small ame button to set the minutes...

Page 13: ...The remote control handset and receiver are program med to function together In case of a replacement of the handset or the receiver you will need to reset the receiver to allow them to function toget...

Page 14: ...RRr If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG VLGH 21 2 VZL...

Page 15: ...battery operated carbon monoxide detector with an alarm shall be installed 2 APPROVED CARBON MONOXIDE DETECTORS Each carbon monoxide detector as required in accordance with the above provisions shall...

Page 16: ...em instructions shall be included with the appliance or equipment installation instructions and 2 The special venting systems shall be Product Approved by the Board and the instructions for that syste...

Page 17: ...IRN JLP IRP Gas Natural Propane Altitude Ft 0 4500 Input Max Btu h 24 000 24 000 Input Min Btu h 6 500 13 000 Manifold pressure in w c 3 95 10 0 Min Supply pressure in w c 5 0 11 0 Max Supply pressure...

Page 18: ...extending the full width and depth of the appliance Flush Wall Finish Forward 534 recessed WARNING HOT HEARTH FLOOR The hearth or floor HOT HEARTH FLOOR The hearth or floor in front of the fireplace...

Page 19: ...12 305 mm 14 356 mm Dimensions Mantel 36 914 mm min See table A B 23 1 8 587 mm to rear vent center 33 1 2 850 mm 14 355 mm Gas line 32 3 16 817 mm 29 3 4 756 mm 26 3 4 679 mm 3 75 mm min To side wall...

Page 20: ...3 4 to wall finish 30 3 4 when using 645CFV Clearview Front 35 1 2 Wall Finish This is the framing width Wall finish to 32 3 16 wide 16 min straight out or off the top venting Allow for elbow if rear...

Page 21: ...completely around all joints and press rmly to seal A high temperature black silicone sealant may be used in the outer joints as a substitute to foil tape Ensure all the pipe joints have a minimum of...

Page 22: ...BLE PIPE LENGTH PIPE LENGTH PIPE LENGTH 817VAK 817VAK PIPE LENGTH 90 ELBOW CEILING FIRESTOP ATTIC FIRESTOP ATTIC INSULATION SHIELD FLASHING STORM COLLAR VERTICAL TERMINATION Typical Co Axial Venting C...

Page 23: ...Prevent rain water and moisture from entering the walls by sealing the joints between the outer vent tube and the inner and outer wall plates We recommend the use of a high quality polyurethane sealan...

Page 24: ...ded to prevent condensation on window 12 30 D Vertical clearance to ventilated sof t located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18 46...

Page 25: ...12 rise 45 elbow directly on flue collar is allowed with min 6 pipe between elbows 1 min all around vertical pipe 3 min above top of horizontal pipe 1 min around bottom sides of horizontal pipe V1 V2...

Page 26: ...quivalent 2 x 45 degrees 90 degrees can be used 5 Each 90 degrees elbow installed on the horizontal plane is equivalent to a 3 feet horizontal pipe therefore 3 feet must be subtracted from allowable h...

Page 27: ...with the dimensions shown in the Co Axial Venting section of this manual Drop a plumb from the ceiling to the center of the appliance vent opening Mark the position on the ceiling Drill a small hole a...

Page 28: ...eplace and chimney The appliance must not be connected to a chimney ue serving a separate solid fuel burning appliance Requires 556CLA Co Axial to Co Linear Appliance Adapter or alternatively a generi...

Page 29: ...inside the rear outlet opening Secure the inner collar with 8 screws 5 Fit the outer collar over inner collar Loosely t the 12 screws Place the adapter 817VAK or Valor terminal kit 551DVK over the col...

Page 30: ...ot required for the co linear application Support Angles Fitting The distance from the wall angles to the front face of the heater case is adjustable between 3 8 inch 10 mm and 1 3 16 inch 30 mm to al...

Page 31: ...the vent con guration See the table below to nd out which position is optimal for each type of installation To t the restrictors loosen the two center screws of the left and right inlet ports Place th...

Page 32: ...rom the front of the heater case to the angles is suitable for the thickness of the wall nish e g tile etc NOTE When adding optional fronts and trims it is important to install heater flush or slightl...

Page 33: ...supply connection to the appliance Pressure test the supply line for leaks The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure t...

Page 34: ...e left edge of the rebox 3 Hold the right hand side panel at an angle and insert its bottom edge inside the rebox Rotate the panel to a vertical position ensuring that the top edge is behind the ange...

Page 35: ...gainst front edge of the sheet metal support 2 Place the top left log on the pin of the rear log The bottom of the log rests against the left of the pilot shield and slightly above 3 Place the front l...

Page 36: ...log onto the pin on the front right log Rest the narrow end in the notch into the rear log 7 Pour some ceramic loose coals on each side of the logs to hide the sheet metal work Do NOT put any coal in...

Page 37: ...m in the rebox rotating down to insert the front rst behind the Front Support Lay the back of the ceramic platform against the rear ceramic panel again being careful not to scrape the ceramic panels W...

Page 38: ...as shown Make sure to leave a gap between the twig and the first rock to allow flame to come up between the twig and the rock 7 Place the right twig across the second and third rocks from the right r...

Page 39: ...indow Re tting Checking IMPORTANT To ensure a safe operation ensure that the spring loaded mechanism functions properly Safety warning plate The receiver and the handset of the remote control system m...

Page 40: ...ance with the ceramic rocks and window installed Increasing aeration will cause the ames to appear more transparent and blue showing more ceramic effects glow Decreasing aeration will cause the ames t...

Page 41: ...r can be installed at the base of a light switch plate IMPORTANT The location of the remote control handset is important to assure proper temperature regulation To obtain a constant temperature we rec...

Page 42: ...42 42 Wiring Diagram Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram QUALIFIED INSTALLER...

Page 43: ...4DSC V Co linear Flex Connector 46DVA ADF Co axial to Co linear Adapter 46DVA GCL TM 4CAA 4DCAB33 556CLA Co linear to Co axial Adapter 46DVA GK TM 4CTA 4DCAT33 Aluminum Flexible Liner 3 diameter NOTE...

Page 44: ...y Flashing TF 4MF Various Venting System Parts Wall Thimble 46DVA WT 4DT WT TM 4WT SV4RSM 4DWT Storm Collar 46DVA SC 4DT SC TM SC SV4AC 4DSC Decorative Plate 46DVA DC 4DT CS TM 4TR SV4PF 4DFPB Cathedr...

Page 45: ...ir from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not cover gl...

Page 46: ...1 29 Pipe valve to pilot 030A226 30 Olive nut for pilot pipe 220K913 31 Pilot shield 4002203 32 Pilot support bracket 330A904 33 Pilot seal 620B995 34 Access plate 4001680 Key Description Part no 35 P...

Page 47: ...1 66 Rock Set Complete 4001791 67 Rock No 1 4001821 68 Rock No 2 4001822 69 Rock No 3 4001823 70 Rock No 4 4001824 71 Rock No 5 4001825 72 Rock No 6 4001826 73 Rock Base 4001792 74 LH Twig 4001827 75...

Page 48: ...21 26 27 28 29 30 22 23 24 25 20 16a 16b 40 41 5 15a 15b 39 4 38 3 13 18 2 12 17 56 57 58 59 60 61 64 62 65 63 80 1 6 6 7 7 9 9a 8 10 11 32 31 37 36 33 34 35 50 48 55 54 53 52 51 45a 45b 46 46a 47 67...

Page 49: ...provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page ll information and mail to Miles Industries Ltd Fireplace Information Model Number...

Page 50: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...

Reviews: