21
Venting
Co-Linear Conversion
Co-Linear Vent Installations
The
fi
replace dimensions are shown below.
1. Place the appliance (
fi
tted with the co-linear adapter)
near the
fi
replace opening but allow space for manip-
ulating the chimney liners on to the appliance.
2. Drop the 3-inch diameter
fl
exible liners into the chim-
ney from outside.
3. Fit the liners to the co-linear adapter paying attention
to inlet and exhaust and move the appliance to its
proper position. Be aware of the minimum liner bend
radius and maximum liner horizontal run as indicated
at right.
4. Fit the termination kit and
fl
ashing to the exterior of
the chimney.
5. Secure the appliance to the
fl
oor or wall if necessary.
Rear or Top Outlet Conversion to Co-Linear Liners using
Valor 556CLA Co-Linear Adapter
(Generic co-axial to co-linear adapter boxes may also be used
as an alternate to the 556CLA).
Only for use when retro
fi
tting a sollid-fuel burning
fi
replace and chimney.
The appliance must not be connected to a chimney
fl
ue serving a
separate solid-fuel burning appliance.
Requires 556CLA Co-Axial to Co-Linear Appliance Adapter (or, alternatively, a
generic adapter), two lengths of 3-inch diameter
fl
exible chimney liner, co-linear
termination kit and
fl
ashing and either high wind vertical vent terminal cap or a
low pro
fi
le vertical termination.
Zero Clearance stand-o
ff
s and shields supplied with
the heater are not required for this application.
Exhaust Spigot
Exhaust
Intake
Outer
Plate
Gasket
556CLA
2 x 3” Liners
26-3/4”
14”
556CLA
2 x 3” Liners
26-3/4”
14”
556CLA on Rear Outlet
556CLA on Top Outlet
Co-Linear installation into
existing F/P
556CLA Kit
Flashing
2 x 3”
liners
3” min.
bend radius
Co-linear
adapter
2 x 3”
liners
18” max.
horizontal run
Co-linear
adapter
650
engine
Max.
40’
Co-Linear installat
existing F/P
Co-linea
adapter
Approved co-linear
termination or approved
co-linear adapter
and approved
co-axial
termination
NOTE: Min. 1/2”
gap required
for air flow