![Valor H3 Series Homeowner'S Manual Download Page 17](http://html.mh-extra.com/html/valor/h3-series/h3-series_homeowners-manual_851422017.webp)
17
Pilot Flame
Pilot Flame
Pilot Flame
1000DWKV2—Driftwood
1000LSKV2—Traditional Logs
1000BLKV2—Birch Logs
Pilot
fl
ame
Thermocouple
probe must be in
fl
ame
Correct
fl
ame appearance
A periodic check of the pilot and burner
fl
ames
should be made. Check after the
fi
re has been on for
at least 30 minutes. The pilot
fl
ame must cover the tip
of the thermocouple probe. The main burner
fl
ame
pattern will vary from
fi
replace to
fi
replace depending
on the type of installation and climatic conditions.
Performance of propane gas
fi
replaces may be
a
ff
ected by the quality of commercial gas supplied
in your area.
The
fi
replace area must always be kept clear and
free from combustible materials, gasoline and other
fl
ammable vapors and liquids.
Inspect the vent terminal outdoors regularly to make
sure that snow, trees, bushes, leaves, or other objects
do not obstruct it. We recommend at least an annual
inspection.
Checking pilot and burner flames
Note
The height and color of your flames can vary
depending on fuel type, fuel quality and mixture,
altitude, and aeration adjustment at or after
installation.
The photos of typical flame appearance are for
illustrative purposes only. Your fireplace may be
operating normally but appear different than the
photos.