background image

4003044-02

Current room 
temperature

Current time

Back cover label

G6R-H3D6

Valor 
logo 
only

© Copyright Miles Industries Ltd., 2011.

For use with Valor GV60 PLUS or MAX* Remote Control Systems ONLY

www.valorfi replaces.com

Non-Thermostatic Handset

The handset GV60NTK is used with the Valor GV60 
PLUS or MAX

*

 receivers to turn the fi re on or off 

and the set the fl ame height. It has no thermostat 
or programming functions and it does not shutdown 
automatically. The handset shows the current time and 
the room temperature.

*

NOTE: The handset GV60NTK does not operate 

the fan control, the lighting control or the duplex 
burner fi replaces with GV60 MAX systems.

Synchronizing the NT handset to the remote 
control receiver

The receiver and the handset of the remote control sys-
tem must be initially synchronized before the fi rst use 
of a new handset.

1.  Insert alkaline batteries in the remote control 

receiver and handset. The receiver is located left of 
the control valve under the burner module.

2.  With a sharp object, press and hold the receiver’s 

reset button until you hear one short and one long 
beeps. Release the reset button after the second 
beep.

3.  Within the subsequent 20 seconds, press the small 

fl ame button (     ) on the remote handset until you 
hear two short beeps confi rming the sychronization 
is set.

This is a one time setting only and is not required when 
changing the batteries in the remote receiver. The 
remote control system is now ready to use.

INSTALLATION & OPERATION INSTRUCTIONS

GV60NTK

Non-Thermostatic Kit

• 

The one-hour feature is maintained when using a 
1265WSK wall switch.

• 

One handset can be used to synchronize multiple 
receivers to activate the one-hour feature.

• 

Synchronizing the receiver again with a thermostatic 
handset will reactivate the thermostat, programming 
and auxiliary functions.

The non-thermostatic 
(NT) handset is 
identifi ed with a Valor 
logo only. It shows 
the current time and 
room temperature. 
The number shown 
on its back cover 
label is G6R-H3D6

Summary of Contents for GV60NTK

Page 1: ...trol receiver and handset The receiver is located left of the control valve under the burner module 2 With a sharp object press and hold the receiver s reset button until you hear one short and one long beeps Release the reset button after the second beep 3 Within the subsequent 20 seconds press the small flame button on the remote handset until you hear two short beeps confirming the sychronizati...

Page 2: ...AN knob on the valve is in ON position 2 Make sure that the switch on the valve is in the I position except on 650 and 1500 fireplace models 3 Press and hold the OFF and large flame buttons until you hear a short acoustic signal Release the buttons The acoustic signals will continue until the pilot lights The flame will be at maximum height until the remote control reads the temperature factory se...

Page 3: ...o back to 2 4 Press the OFF button Handset Receiver Match The remote control handset and receiver are programmed to function together In case of a replacement of the handset or the receiver you will need to reset the receiver to allow them to function together Contact your dealer for details Low Battery Indication Remote handset BATT will appear on the display when the battery needs to be replaced...

Page 4: ...intu pressez et maintenez le bouton RESET sur le récepteur jusqu à ce que un court et un long bips se fassent entendre Relâchez le bouton 3 Dans le 20 secondes suivantes pressez sur le bouton de la petite flamme sur la manette jusqu à ce que vous entendiez deux courts bips confirmant la synchronisation La télécommande est maintenant prête à être utilisée Cette procédure n est effectuée qu une seul...

Page 5: ...auteur maximale 1 Assurez vous que le bouton de contrôle MAN sur la soupape est en position ON 2 Assurez vous que l interrupteur Marche arrêt est en position I marche à l exception des foyers 650 et 1500 3 Appuyez et maintenez les boutons OFF et grande flamme jusqu à ce que vous entendiez un court signal sonore Relâchez les boutons Les signaux sonores continueront jusqu à ce que la veilleuse soit ...

Page 6: ...er recommencez l étape 2 4 Appuyez sur OFF pour terminer le réglage Indicateur de remplacement des piles Manette L indicateur BATT apparaîtra sur l écran lorsque les piles doivent être remplacées Remplacez la pile de la manette par une pile alcaline de 9 V Récepteur Trois 3 court signaux sonores lorsque le moteur de la soupape fonctionne indiquent que les piles doivent être remplacées Remplacez le...

Reviews: