Safety and your fireplace

Glass window

• The glass front assembly must be in place and sealed 

before the unit can be placed into safe operation.

• The glass front assembly must only be replaced as a 

complete unit, as supplied by the 

fi

 replace manufac-

turer. No substitute material may be used.

• Do not use abrasive cleaners on the glass front as-

sembly. Do not attempt to clean the glass when it is 

hot.

Venting

• This unit must be used with a vent system as de-

scribed in its installation manual. No other vent 

system or components may be used.

• Never obstruct the 

fl

 ow of combustion and ventila-

tion air. Keep the front of the appliance clear of all 

obstacles and materials for servicing and proper 

operation.

• This gas 

fi

 replace and vent assembly must be vented 

directly to the outside and must never be attached 

to a chimney serving a separate solid fuel burning 

appliance. Each gas appliance must use a separate 

vent system. Common vent systems are prohibited.

Intended use 

• This appliance is designed and approved as a supple-

mental heater and provides the potential for most 

energy conservation when used while attended. The 

use of an alternate primary heat source is advisable.

• This unit is not for use with solid fuel.

• Do not use this heater as a temporary source of heat 

during construction.

Installation and Servicing

• Installation and repair should be done by a quali

fi

 ed 

service person. The appliance should be inspected 

before use and at least annually by a professional 

service person. More frequent cleaning might be 

required due to excessive lint from carpeting, bed-

ding material, et cetera. It is imperative that control 

compartments, burners, and circulating air passage-

ways of the appliance be kept clean.

• Do not use this appliance if any part has been under 

water. Immediately call a quali

fi

 ed service technician 

to inspect the appliance and to replace any part of 

the control system and any gas control that has been 

under water.

Maintenance

• Keep the unit’s control compartment, burner, and 

circulating air passageways clean to enable adequate 

combustion and ventilation air.

• Inspect the external vent cap on a regular basis to 

ensure that no debris, plants, trees, or shrubs are 

interfering with air 

fl

 ow. 

WARNING

Do not operate this appliance with the 

glass front removed, cracked, or broken. 
Do not strike or slam the glass front.
Replacement of the glass front should 

be performed by a licensed or quali

fi

 ed 

service person. 

Summary of Contents for G3 739

Page 1: ...you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Hot glass will cause burns Do not to...

Page 2: ...market permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convert...

Page 3: ...___________________ ________________________________________________ Please ask your installer for these details if they are not already provided or see page 7 Welcome to Valor Contents Safety and you...

Page 4: ...are installed Some materials or items although safe may dis color shrink warp crack peel and so on because of the heat produced by the fireplace Avoid placing candles paintings photos and other combus...

Page 5: ...ded The use of an alternate primary heat source is advisable This unit is not for use with solid fuel Do not use this heater as a temporary source of heat during construction Installation and Servicin...

Page 6: ...nition Young children should be carefully supervised when they are in the same room as the appliance Toddlers young children and others may be sus ceptible to accidental contact burns A physical barri...

Page 7: ...supervision device which will shut o the gas supply if for any reason the pilot flame goes out This device incorporates a fixed probe which senses the heat from the pilot flame If the probe is cool th...

Page 8: ...vidual fireplace may appear differently depending on your model and installed options Barrier Screen Window Liners Fuel Bed Logs embers pebbles Fret or Access Panel Front Trim Bolts Top of Window Bolt...

Page 9: ...te or ON OFF button on wall switch If the flames or pilot are on they will go out and you will hear the valve motor wind down You will hear a clunk and a beep indicating that the valve has received th...

Page 10: ...from the battery holder in the control area see next page and the handset To activate the fireplace again press on I WARNING Risk of severe burns Surface of the fireplace are very hot during operation...

Page 11: ...eplace is hot Let the fireplace cool first before touching it Caution Do not use a screwdriver or other metallic object to remove the batteries from the battery holder or the handset This could cause...

Page 12: ...cleaner Abrasive cleaners must not be used Be careful not to scratch the glass when cleaning See Cleaning your fireplace on page 14 Inspect the operation of the flame safety sys tem Pilot or Flame re...

Page 13: ...Remove the window for cleaning 1 Unhook the trim with barrier screen 2 Locate the four spring loaded bolts at the top and bottom of the window Turn each bolt a quarter turn to release the bolt s pin f...

Page 14: ...by Rutland Turtle Wax Do not clean the glass while it is hot Always securely replace the window and the barrier screen before lighting see next page If broken glass panes may only be replaced as a co...

Page 15: ...Glass Warning plate has been removed from the front lower corner of the window reinstall it by sliding it between the glass and the frame as indicated below 7 Re install the front and barrier screen W...

Page 16: ...and burner flames should be checked periodically Check after the fire has been on for at least 30 minutes The pilot flame must cover the tip of the thermocouple probe The main burner flame pattern wil...

Page 17: ...lor of your flames can vary depending on fuel type fuel quality and mixture altitude and aeration adjustment at or after installation The photos of typical flame appearance are for illustrative purpos...

Page 18: ...ntrol handset but the batteries in the battery holder See page 11 for instructions on how to replace the batteries Why do I hear popping or snapping noises As your fireplace heats and cools with norma...

Page 19: ...d service Please contact your dealer see page 3 or visit valorfireplaces com contact for a list of dealers near you Who can service my fireplace We recommend having your fireplace serviced before init...

Page 20: ...form to all applicable codes including national and local gas appliance installation codes and building and re codes d The owner must comply with all operating instructions e The Company is not respon...

Page 21: ...install repaired or replacement parts f The initial owner of the unit will be responsible for any shipping charges for replacement parts as well as travel time incurred by the dealer to perform the w...

Page 22: ...h SET scrolls through modes and settings OFF returns to set mode turns the burner and WKH SLORW R DUJH DPH EXWWRQ DPHV up sets hours temperature 6PDOO DPH EXWWRQ DPHV GRZQ DQG R VHWV PLQXWHV temperatu...

Page 23: ...MAN Manual Mode Manual ame height adjustment TEMP Daytime Temperature Mode When pilot is lit room temperature is measured and compared to set temperature Flame height automatically adjusts to reach D...

Page 24: ...n each 24 hour cycle Programs P1 and P2 must be set in the following order during a 24 hour cycle P1 P1 P2 and P2 Day Time temperature high program period Night Time temperature low program period Def...

Page 25: ...extended period of time the system automatically extinguishes the pilot This feature helps the consumer realize cost bene ts by automatically eliminating energy consumption during non heating months a...

Page 26: ...26 Notes...

Reviews: