Replace the dress guard. Locate the bottom of the dress guard in the two holes in the

bottom panel apron. Push the guard back so that the two spring projections at the top of the
guard engage in the slots under the front decorative canopy.

MAINTENANCE

Regular maintenance

In order to achieve and maintain high levels of personal safety and performance
efficiency, it is essential that the opening at the back of the fire and the flue are kept clear
of any form of obstruction. It is possible that deposits of mortar or soot could fall and
accumulate causing the flue to be blocked or restricted and so preventing proper
clearance of dangerous exhaust fumes.
In the United Kingdom it is the law that a landlord must have any gas appliance, flue and
pipework which is situated in a tenant’s premises checked for safety at least every twelve
months by a competent person (In the U.K., a CORGI registered installer).
We recommend that all gas appliances and their flues, wherever situated, are checked
annually.

Servicing

 

In the United Kingdom servicing can be carried out either by a Valor Service engineer

or a CORGI registered installer.

 

If you require your fire to be serviced, please contact 

Valor Service

 on 

08706 090

081

 and quote the following details;

a)

 

Model, name and number.

b)

 

Appliance serial no. (To be found on a label near the bottom of the right side of the

case.)

 

If you wish to replace any radiants and do not know where they can be obtained

please contact 

Valor Spares 

on 

08706 000 454

 for your nearest stockist.

 

In the United Kingdom, for general advice about gas and your gas fire call the

VALOR TECHNICAL HELPLINE      08706 061 065.

 

In the Republic of Ireland call 

0044 08706 061 065 

for all enquiries.

Summary of Contents for Firelite OXYSAFE 2

Page 1: ...We trust that this guide gives sufficient details to enable your appliance to be operated and maintained satisfactorily However if further information is required our Valor Technical Helpline will be...

Page 2: ...st Standards Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a CORGI registered company...

Page 3: ...on of your Valor gas fire by providing simple and informative instructions to ensure that you benefit from the excellent performance and features it has to offer If you require further assistance or a...

Page 4: ...le or non combustible materials This clearance is necessary to allow the case to be lifted off for servicing and also allows sufficient access to operate the control knob For a shelf made from wood or...

Page 5: ...or become discoloured when close to a heating appliance Please bear this in mind whenever you are considering redecorating Provide a minimum clearance of 50mm between the outer case sides and any corn...

Page 6: ...OWNER S GUIDE Page 6 Figure 1 Dimensions clearances APPLIANCE DIMENSIONS...

Page 7: ...goes out due to lack of oxygen or for any other reason If this device starts to repeatedly shut off the gas get expert advice This device incorporates a probe that senses that the heat from the pilot...

Page 8: ...4 Centre radiant fully on Outer radiants on low 5 All radiants fully on To turn off partially depress the knob and turn clockwise to off Wait at least three minutes before attempting to relight Light...

Page 9: ...lways use the correct type of replacement radiant Ask for Valor part number 0544649 GC No 125 164 Turn the fire off and allow it to cool before attempting to remove the radiants Remove the dress guard...

Page 10: ...ue and pipework which is situated in a tenant s premises checked for safety at least every twelve months by a competent person In the U K a CORGI registered installer We recommend that all gas applian...

Reviews: