PART1: APPLIANCE DATA
This appliance does not contain any component manufactured from asbestos or
asbestos related products.
The appliance data label and wiring diagram are on a plate chained below the burner
and visible when the control cover is removed.
Gas:
Natural (G20)
Inlet pressure:
20mbar (8in w.g.)
Gross input:
Max. 6.0kW (20,500 Btu/h)
Min.2.2kW (7,500Btu/h)
Burner test pressure (cold):
18.2+0.75mbar (7.3+0.3 in w.g.)
Gas connection:
8mm pipe
Burner injector:
Bray cat. 82 size 360
Pilot & atmosphere sensing device:
SIT ref. OP9044
Ignition:
Piezo electric. Integral with gas tap
Aeration:
Non-adjustable
Electrical supply:
230V
~
50Hz AC
Fan motor rating:
55W
Fuse rating:
3A
PART2: GENERAL INSTALLATION REQUIREMENTS
The installation must be in accordance with these instructions.
For the user’s protection, in the United Kingdom it is the law that all gas appliances are
installed by competent persons in accordance with the current edition of the Gas Safety
(Installation and Use) Regulations. Failure to install the appliance correctly could lead
to prosecution. The Council for the Registration of Gas Installers (CORGI) requires
its members to work to recognised standards.
In the United Kingdom, all electrical supply installation must be installed in
accordance with the current edition of the IEE Wiring Regulations (BS7671).
In the United Kingdom the installation must also be in accordance with:
a)
All the relevant parts of local regulations.
b)
The current edition of the Building Regulations issued by the Department of the
Environment and the Welsh Office or the Building Standards (Scotland)
(Consolidation) Regulations issued by the Scottish Development Department.
All relevant codes of practice.
c)
The relevant parts of the current editions of the following British Standards:-
BS 5440 Part 1
BS 5871 Part 2 & 3
BS 6891
In the republic of Ireland the installation must also conform with:
a)
The current editions of:-
IS 813
ICP3
b)
All relevant national and local rules in force.
c)
The current ETCI National Rules for Electrical Installation.
Electrical isolation of the unit should be by means of a switched 3A fuse spur that
should be readily accessible to the user, easily identifiable and sited within reach of the
mains cable provided. It should only connect this appliance.
This fire is a fan flued appliance for installation on an outward facing wall of a
conventional home which does not have a purpose built flue or chimney.
As supplied, the appliance is suitable for homes constructed of brick, stone, etc., the
appliance can be installed into walls up to a maximum thickness as shown below.
If the fire box is in front of the finished wall surface: 600mm (23 5/8in) max.
These dimensions are from the finished internal wall surface (including any surround material) to
the external wall surface.