Valor BOLERO BR626 Installer'S Manual Download Page 18

18

Safety First.

Valor fires are CE Approved and designed to meet the appropriate British Standards and

Safety Marks.

Quality and Excellence.

At the heart of every Valor fire.

All Valor fires are manufactured to the highest standards of quality and excellence and are

manufactured under a BS EN ISO 9001 quality system accepted by the British Standards

Institute.

The Highest Standards

Valor is a member of the Society of British Gas Industries which works to ensure high

standards of safety, quality and performance.

Careful Installation

Valor is a Corgi registered company. All our gas fires must be

 installed by a competent Corgi Registered Installer in accordance

with our Installer Guide and should not be fitted directly on to a

carpet or floor of combustible material.

Valor Heating, Erdington, Birmingham B24 9QP

Because our policy is one of constant development and improvement, details may vary slightly from those given in this

publication

 

© Valor Heating

Summary of Contents for BOLERO BR626

Page 1: ...A L L E R G U I D E V A L O R B O L E R O M O D E L B R 6 2 6 9 5 0 0 4 3 6 B r a s s 9 5 0 0 4 3 7 C h r o m e 9 5 0 0 4 3 8 B l a c k I n s e t L i v e F u e l E f f e c t G a s F i r e GB IE Pleas...

Page 2: ...help Please telephone 0345 626341 Local call rates apply P l e a s e l e a v e t h i s I n s t a l l e r G u i d e w i t h t h e u s e r This appliance is for use with natural gas G20 This appliance i...

Page 3: ...the work area and always wash your hands before eating or drinking This appliance does not contain any component manufactured from asbestos or asbestos related products The appliance data label is on...

Page 4: ...mponents are not replaceable Note that soft wall coverings e g embossed vinyl etc are easily affected by heat They may scorch or become discoloured when close to a heating appliance Please bear this i...

Page 5: ...table Chair brick removal may be required At least 50mm clearance must be available from the flue outlet to any fireplace component The appliance is designed to cater for low lintel installations min...

Page 6: ...ect for any evidence of mishandling which might affect the performance Each unit is flame and soundness tested before it leaves the factory and as a result there may be slight discoloration around the...

Page 7: ...through the upper of the holes as shown in figure 5c Give the cables a pull so that they grip against the debris deflector flanges On no account should plastic wall plugs be used Thread the cables thr...

Page 8: ...h the current edition of BS6891 A long brush may be required to reach some joints PRELIMINARY BURNER CHECKS Some burner operations can be checked at this stage Checking now will mean that less disasse...

Page 9: ...nce alight and set at maximum output After checking turn off the appliance Remove the pressure gauge and replace the test point sealing screw Relight the appliance Turn to the maximum output position...

Page 10: ...ngle coal in the centre of the front coal ensuring that it bridges across to the matrix as shown in figure 10 Place the other 4 coals resting between the front coal and the coal matrix each side of th...

Page 11: ...two each side of the centre coal directly behind the front row of coals Figures 13 Place the remaining four coals behind the second row of coals two each side of the centre coal shape formed within t...

Page 12: ...ck must be made before leaving the installed appliance with the customer Make this check with the appliance fully installed with the ceramic fuel effects and front surround in position Close all doors...

Page 13: ...reason wait at least three minutes before relighting Stress that if the monitoring system repeatedly shuts off the fire the appliance should be switched off and a specialist should be consulted Advise...

Page 14: ...be removed as follows with out detaching the front surround or front casting Remove the plaques clamping strips by removing the retaining screws Remove the plaques centre gasket bottom gasket and if n...

Page 15: ...tap body Remove the plug rotating slightly while pulling Clean and grease the plug lightly with a suitable grease Do not apply excessive grease Particularly make sure that the gas ports in the tap ar...

Page 16: ...ne Gas Appliances 1 577949 B Gas tap spark generator 1 569429 C Spark generator 1 521069 D Control knob 1 545979 Pilot Unit For Natural Gas Appliances OP9030 540979 E Pilot Unit For Propane Gas Applia...

Page 17: ...E 0345 626341 To report faults or arrange for your fire to be serviced VALOR SERVICE 0121 386 6203 To order spares or for sales information VALOR SALES 0121 386 6260 CALLERS IN THE REPUBLIC OF IRELAND...

Page 18: ...ards Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a Corgi registered company All our...

Reviews: