![Valor BOLERO BR626 Installer'S Manual Download Page 15](http://html1.mh-extra.com/html/valor/bolero-br626/bolero-br626_installers-manual_3550227015.webp)
15
TO REMOVE THE GAS TAP/F.S.D
•
Remove the burner unit.
•
Disconnect the electrode lead from tab underneath the electrode.
•
Undo the thermocouple nut at the gas tap
•
Disconnect the inlet pipe at the tap end
•
Disconnect the pilot pipe at the tap end.
•
Disconnect the main burner pipe at the tap end
•
Pull off the control knob
•
Remove the gas tap fixing nut. Pull the tap clear of the control plate.
•
Replace in the reverse order.
TO REMOVE THE PIEZO GENERATOR
•
Remove the gas tap/F.S.D. as above
•
Make sure that the tap is in the off position
•
Remove the circlip holding the piezo unit to the tap. Remove the piezo unit.
•
Replace in the reverse order.
TO GREASE THE CONTROL TAP/F.S.D
•
Detach the tap and remove the piezo generator making sure that the tap is in the off position.
•
Remove the two screws from the head of the tap. Remove the niting head and spindle complete with collar
and spring.
•
Note the position of the slot in the plug - mark its position on the tap body.
•
Remove the plug rotating slightly while pulling.
•
Clean and grease the plug lightly with a suitable grease. Do not apply excessive grease. Particularly, make
sure that the gas ports in the tap are not restricted by grease.
•
Push the plug into the tap body and position the slot in line with the mark previously made on the tap
body.
•
Reassemble the niting head and spindle complete with collar and spring making sure that the components
are correctly engaged. Check the operation of the tap.
•
Refit the piezo generator.
TO REMOVE THE MAIN BURNER ELBOW INJECTOR
•
Remove the burner unit.
•
Disconnect the main burner pipe from the elbow injector. If necessary, loosen the pipe at the gas tap end
to swing the pipe clear of the injector.
•
Unscrew the elbow injector from the support bracket.
•
Refit in the reverse order.
TO REMOVE THE APPLIANCE FROM THE FIREPLACE
•
Remove the 14 loose coals, front base coal and rear base coal.
•
Slacken the hexagonal adjusters on the cable retainers and unscrew to release the cables.
•
Refit as described in the relevant installation sections. Make sure gas soundness, sealing spillage test and
performance are satisfactory.