Description

Part 

Number

1

Auto

fi

 re vent plate assembly

4006540

2

Exhaust plate gasket

4001662

3

Valve access cover

4002289

4

Side brick anchors (2)

4001283

5

LH Explosion relief assembly

4001286

6

RH Explosion relief assembly

4001287

7

Valve access panel gasket

4002664

8

Valve access plate

4002510

9

Shrouds (2)

4002446

10 Contemporary burner platform

4004849

11 Window frame assembly (inc. glass)

4004463S

12 Hot glass warning plate

4003093

13

Burner module assembly 

(natural gas)

4004713

Burner module assembly 

(propane gas)

4004714

14

Top gasket

4002403

15

Side gaskets (2)

4002404

16

Bottom gasket

4002405

17

Thermocouple/pilot sealing plate

4002700

18

Pipe sealing plate

4004338

19

Straight connector

220K891

20

Thermocouple interrupter

4001037

21

Switch bracket

4002566

22

GV60 valve assembly (natural gas)

4004840S

GV60 valve assembly (propane gas) 4004841S

23

36” 

fl

 ex pipe assembly

4002475

24

Main burner pipe assembly

4004047

25

Pilot shield

4004559AH

26

Pilot assembly 51 (natural gas)

4006030

Pilot assembly 30 (propane gas)

4006031

27

Thermocouple (1000 mm)

4004801

28

Pilot injector #51 (natural gas)

4000735

Pilot injector #30 (propane gas)

4000736

29

Pilot hood 2-

fl

 ame

4001756

30

Extended nut

4001855

31

Electrode

4001856

32

Injector elbow #850 (natural gas)

9730010

Injector elbow #300 (propane)

9730035

Description

Part 

Number

33

Injector nut

420K464

34

Insulation sleeve for ignition cable

4002244

35

Ignition cable (900 mm)

4004800

36

Cable interrupter

4001035

37

Switch with cable

4001036

38

Wiring harness

4001187

39

Receiver MAX

4002422

40 Auxiliary battery holder and cable

a

Battery holder

4006553

b

Battery holder cable 1500 mm

4006552

41 Handset GV60 MAX

4002251

42 Remote control wall holder

9000008

43 Driftwood Kit

1101DWK

44

Logs & Pebbles Set

4004369

45

LH rear log

4004370

46

RH rear log

4004371

47

LH cross log

4004372

48

Brown beach pebbles (2)

4003082

49

White beach pebble

4003084

50

Black beach pebble

4003085

51

Small grey beach pebbles (2)

4003086

52

Beige beach pebble

4003087

53

Mixed black/grey shale - bagged

4004503

58 Decorative Glass Murano

785XDGM

59

Pilot shield cover

4004699AH

60

Glass pad

4004798

61

Glass platform

4004696

62

Platform retainers (2)

4004697AH

63

1/2” Clear 

fi

 reglass (1 bag)

4004521

64 Liner panels—complete sets

a

Ledgestone V3

786LSLV3

b

Re

fl

 ective Glass

787RGL

c

Ceramic 

fl

 uted black

788FBLV2

d

Valor red brick

789VRLV2

65 Top panel

a

Ledgestone V3

4007997

b

Ceramic black

4002374

c

Ceramic black

4002374

d

Valor red brick

4002385

Appendix C - Spare Parts

Summary of Contents for AutoFire G4

Page 1: ...r call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Hot glass will cause burns Do not touch glass until cooled Never allow...

Page 2: ...h Vancouver BC Canada V7H 3B1 T 604 984 3496 F 604 984 0246 valorfireplaces com This appliance may be installed in an after market permanently located manufactured mobile home where not prohibited by...

Page 3: ...paration 14 Unpack the Appliance 14 Remove Window 15 Install Fan Kit if used 15 Installation 16 Connect Venting 16 Gas Supply 17 Liner Panels 19 Remove and Re install Burner if necessary 19 Fuel Beds...

Page 4: ...installed Some materials or items although safe may discolor shrink warp crack peel and so on because of the heat produced by the fireplace Avoid placing candles paintings photos and other combustibl...

Page 5: ...st use a separate vent system Common vent systems are prohibited WARNING Do not operate this appliance with the glass front removed cracked or broken Replacement of the glass front should be performed...

Page 6: ...del 785YN 785YP Gas Natural Propane Altitude Ft 0 4 500 feet Input Maximum Btu h 28 000 26 000 Input Minimum Btu h 15 000 13 000 Manifold Pressure in w c 3 2 9 5 Minimum Supply Pressure in w c 5 11 Ma...

Page 7: ...ing 4 Sided Trims 4003371AZ 798FFB Black 798FFV Vintage iron 798FFZ Bronze 799ED Edgemont Door Kits 4004348AZ 799EDFZ Bronze 799EDFN Nickel Backing Plates choose one 799BPB 1 799BPB 2 799BPB 3 3 Sided...

Page 8: ...ance by 2 13 16 72 mm Plan accordingly Dimensions 33 838 mm 24 610 mm 15 381 mm 15 381 mm 4 102 mm 3 76 mm 3 76 mm 3 76 mm 23 584 mm to top of firebox Gas line access Gas line approx 24 610 mm of flex...

Page 9: ...aterials that are reported as passing ASTM E 136 Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 C Clearances WARNING Some materials or items although safe may discolo...

Page 10: ...side of the appliance liner box Floor Hearth Clearances Combustible shims supports may be used beneath the appliance to level or raise the appliance within the existing fireplace cavity Combustible fl...

Page 11: ...eet Also check that you have A fuel bed packed separately Liner panels packed separately Venting accessories Electrical accessories if using a fan kit Any other ordered accessories 4 Carefully read th...

Page 12: ...sting non combustible hearth Combustible hearth or floors within 16 of insert must be a minimum 4 102 mm below bottomr of insert Gas insert does not require a hearth WARNING Some materials or items al...

Page 13: ...allowable vertical vent termination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vertical height 10 ft measured to bottom of termination Maximum horizontal run...

Page 14: ...ting Dampers Factory built zero clearance fireplaces will require the damper to be removed in order to install the vent liners These dampers are usually bolted into place Dampers in masonry fireplaces...

Page 15: ...commend that where possible the fan be installed before the appliance is fitted into the cavity Refer to instructions provided with the 795CFKV2 to install the fan 6 power cord Remove Window The windo...

Page 16: ...ebox by sliding it towards the back of the firebox 3 Fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure liners to collars with hose clamps inc...

Page 17: ...upply of gas su cient to meet the maximum demand of the appliance without undue loss of pressure Sealant used must be resistant to the action of all gas constituents including LP gas Sealant should be...

Page 18: ...er installation or servicing All leaks must be corrected immediately When testing for leaks Make sure that the appliance is turned o Open the manual shut o valve Test for leaks by applying a liquid de...

Page 19: ...lternate Inlet Connection In cases where local codes do not permit the flex connector to be used inside the appliance case reconnect the flex connector outside of the appliance case A cut out is provi...

Page 20: ...nifold bracket as indicated 2 Grab the burner and gently pull up the rear first while pushing back and unhooking the front tabs from their retaining lances Be careful not to hook the pilot hood as you...

Page 21: ...Note There are two sets of holes for this log de pending which type of gas is uesd for the appliance Natural gas fire Place the log forward in the fire box Propane gas fire Place the log rearward in t...

Page 22: ...add some shale on cavity outer edge Note Ensure the area within the pilot shield is clear of shale pieces Pebbles Place the pebbles on the platform as shown below IMPORTANT Approved for use only with...

Page 23: ...e glass platform on top of the retainers Installation Fuel Beds 4 Carefully spread the glass by hand on top of the burner within the platform opening 5 Install the square glass panel on top of the pil...

Page 24: ...e as indicated below Window frame Bottom railing Hot Glass Plate WARNING The window unit must be correctly installed fastened and sealed after servicing or serious bodily injury and or damage to the a...

Page 25: ...hold the receiver s RESET button until you hear one short and one long beep Release the reset button after the second beep 5 Within the subsequent 20 seconds press the small flame button on the remote...

Page 26: ...isible at the left hand end of the burner Increasing aeration open will cause the flames to appear more transparent and blue showing more ceramic e ects glow Decreasing aeration close will cause the f...

Page 27: ...ront Trim and Barrier Screen Install the front or trim chosen by the customer for their fireplace Install as well the barrier screen which is provided with the front or trim Show the customer how to a...

Page 28: ...that the holder can be installed at the base of a light switch plate IMPORTANT The location of the remote control handset is important to assure proper temperature regulation To obtain a constant temp...

Page 29: ...LOT MAN Knob Combination Control Valve Main Valve Knob PANEL red yellow Receiver Antenna RESET Button Optional Wall Switch Kit Connector Thermocouple 8 Wire Cable bundled ON OFF Switch Optional 795CFK...

Page 30: ...T33 Aluminum Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmaster and others 2280 Series AF3 35L TM ALK33 9...

Page 31: ...I RX VPHOO JDV 6TOP Follow LQ WKH VDIHW LQIRUPDWLRQ DERYH RQ WKLV ODEHO I RX GRQ W VPHOO JDV JR WR WKH QH W VWep 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER 21 2 VZLWFK LQ 21 SRVLWLRQ 0 1 NQR...

Page 32: ...arth SET scrolls through modes and settings OFF returns to set mode turns the burner and WKH SLORW R DUJH DPH EXWWRQ DPHV up sets hours temperature 6PDOO DPH EXWWRQ DPHV GRZQ DQG R VHWV PLQXWHV temper...

Page 33: ...lot is lit room temperature is measured and compared to set temperature Flame height automatically adjust to reach Daytime Set Temperature Light Dimmer Mode Not available on this replace Fan Mode Turn...

Page 34: ...ss SET to scroll to TEMP Hold SET button until TEMP ashes To set Night Time Temperature increases temperature decreases temperature Press or wait to complete setting Setting Program Timers You can pro...

Page 35: ...ended period of time the system automatically extinguishes the pilot This feature helps the consumer realize cost bene ts by automatically eliminating energy consumption during non heating months and...

Page 36: ...9 Pilot hood 2 flame 4001756 30 Extended nut 4001855 31 Electrode 4001856 32 Injector elbow 850 natural gas 9730010 Injector elbow 300 propane 9730035 Description Part Number 33 Injector nut 420K464 3...

Page 37: ...t side panel a Ledgestone V3 4007998 b Reflective Glass 4004708 b Filler panel 4002776 c Ceramic fluted black 4002377 d Valor red brick 4002381 68 Right side panel a Ledgestone V3 4007999 b Reflective...

Page 38: ...68 1 2 3 4 5 7 8 9 10 11 13 6 19 24 25 20 14 15 15 17 18 16 26 29 30 31 32 33 21 22 23 4 43 44 58 45 46 47 48 49 50 51 52 53 61 62 62 63 60 59 40 35 36 37 42 6 34 38 39 41 69 785XDGM 1101DWK 70 Appen...