DO

 

Always use a fireguard complying with BS6539 or BS6778 for the protection of young
children, the elderly or infirm.

 

Wait three minutes before attempting to relight if the fire is switched off or the flames
are extinguished for any reason.

 

Get advice about the suitability of any wall covering near your fire. Soft wall coverings
(e.g. embossed vinyl, etc.) which have a raised pattern are easily affected by heat. They
may, therefore, scorch or become discoloured when close to a heating appliance.
Please bear this in mind whenever you are considering redecorating.

 

Provide a minimum clearance of 100mm from the outside of the fire case to any corner
wall or other combustible surface that projects beyond the front of the appliance. On
the right hand side this is also the minimum recommended clearance to non-
combustible surfaces to allow for access. On the left hand side a 10mm access
clearance from a non-combustible surface is recommended (See figure 1). Please bear
this in mind if ever you are altering the room.

DON’T

 

Hang clothing, towels or any other fabrics over the fire.

 

Throw paper or other materials onto your fire.

 

Use the fire with damaged base coals.

 

Put more loose coals on the fire than the number given in this guide or use any coals
other than those authorised for this fire. Incorrect combustion could result.

 

Attempt to clean or service the fire until it has been switched off and allowed to cool
completely.

Summary of Contents for ALPHA 647

Page 1: ...is guide gives sufficient details to enable the appliance to be operated and maintained satisfactorily However if further information is required our Valor Technical Helpline will be pleased to help P...

Page 2: ...andards Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a CORGI registered company All o...

Page 3: ...appliance by providing simple and informative instructions to ensure that you benefit from the excellent performance and features it has to offer If you require further assistance or any advice about...

Page 4: ...Safety installation use Regulations In the Republic of Ireland installation must be in accordance with all national and local regulations in force Have the chimney swept prior to installation if it w...

Page 5: ...om the outside of the fire case to any corner wall or other combustible surface that projects beyond the front of the appliance On the right hand side this is also the minimum recommended clearance to...

Page 6: ...OWNER S GUIDE Page 6 APPLIANCE DIMENSIONS Figure 1 Appliance Dimensions...

Page 7: ...expert advice This device incorporates a probe which senses that the heat from the pilot flame is correct If this probe is cool the device will prevent any gas flow unless the control knob is kept dep...

Page 8: ...ut have the fire serviced ii When first turned on the flames will appear predominantly blue The coals will take time to warm up Although some glow will be seen after approximately ten minutes the full...

Page 9: ...the release of dust is kept to a minimum To ensure that the release of fibres from these RCF articles is kept to a minimum during installation and servicing we recommend that you use a HEPA filtered v...

Page 10: ...ld rest on the ledges at the sides and back of the firebox and its rear face should touch the rear ceramic wall See figure 5 3 Place the front base coal in the firebox with its bottom front locating o...

Page 11: ...oal of the rear base coal as shown in figure 9 7 Place the remaining type B coal at the right side of the firebox between the front and rear base coals The letter B should be upright The coal should t...

Page 12: ...dom servicing can be carried out either by a Valor service engineer or a CORGI registered installer If you require your fire to be serviced please contact Valor Service on 08706 090 081 and quote the...

Reviews: