background image

Packing Contents:

1 Wall Bracket A

2 Screws B

1 Screw C

2 Wall Anchor D

1 Spacer E
   (detach before assembly)

1 Wall Bracket F

Switch Plate

Alternative 1

Alternative 2

Alternative 3

Door hinge tabs 

should face inwards

Remote Control Handset Wall Holder Installation

Side Shrouds Installation

The remote control kit for this 

fi

 replace 

comes complete with a wall-mounted holder. 
This holder is not required in all installations 
but is provided as an optional feature for 
those customers who wish to mount the 
remote handset to the wall.
To install the holder to the wall, 

fi

 nd a 

convenient location and use the hardware 
provided with the kit. See the diagram below 
for required hardware and con

fi

 gurations. 

Note that the holder can be installed at the 
base of a light switch plate.

IMPORTANT

. The location of the remote 

control handset is important to assure proper 
temperature regulation. To obtain a constant temperature, we recommend that the handset should be between 3 
and 15 feet away from the appliance 

but not directly above it

. We also advise that the handset should be located 

away from any other heat source and not in direct sunlight as this may affect the temperature sensor located in the 
remote handset.

The side shrouds are required to install the front on 
the appliance. They are supplied with the engine.
Fit them to the appliance outer case as indicated 
(2 screws/side).

Front, Trim and Barrier Screen Installation

Install the front or trim chosen by the customer for their 

fi

 replace. Install as well the barrier screen which is 

provided with the front or trim.
Show the customer how to access the controls when 
the front or trim are installed and how to remove them. 

Follow the instructions provided with the front or trim 
and leave those instructions behind for the customer’s 
further reference.

34

QUALIFIED 
INSTALLER

Summary of Contents for 785ILNV2

Page 1: ...is appliance is not convertible for use with other gases unless a certified kit is used This appliance is a domestic room heating appliance It must not be used for any other purposes such as drying cl...

Page 2: ...stment 33 Side Shrouds Installation 34 Front Trim and Barrier Screen Installation 34 Remote Control Handset Wall Holder Installation 34 Wiring Diagram 35 Approved Venting Components 36 Warranty 37 Spa...

Page 3: ...e and draperies Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance This unit MUST be used with a...

Page 4: ...al contact with a hot surface A physical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers y...

Page 5: ...the hearth as a seat or shelf as a seat or shelf Some materials or items although safe may Some materials or items although safe may discolor shrink warp crack peel and so on discolor shrink warp cra...

Page 6: ...BRASSO POLISH PLUS by KELKEM COOK TOP CLEAN CREME by ELCO WHITE OFF by RUTLAND TURTLE WAX Do not clean the glass while it is hot Always securely replace the window and the barrier screen before lighti...

Page 7: ...attery box from the receiver The appliance uses four 1 5 V AA alkaline batteries for its battery box and one 9 V alkaline battery for its handset Batteries should last one to two seasons depending on...

Page 8: ...ically see pages 9 14 The Wall Switch optional can be used to turn on off and to increase or decrease the flame height see 1265WSK Wall Switch Kit NOTE The remote control in the AUTO mode will overrid...

Page 9: ...Before using the remote control system for the first time the receiver and the handset must be synchronized See the section Remote Control Initial Set up on page 32 of this manual Set scrolls through...

Page 10: ...ersa The time display will flash after either Installing the battery or Simultaneously pressing the large flame and small flame buttons Press large flame button to set the hour Press small flame butto...

Page 11: ...nd goes to the displayed level after 10 seconds The fan stops 10 minutes after the gas is OFF or at pilot NOTE The function AUX is blocked in programming mode TIMER P1 or P2 when the Nighttime Set bac...

Page 12: ...simply wait to complete programming SETTING THE DAYTIME TEMPERATURE SETTING THE NIGHTTIME SETBACK TEMPERATURE Default Settings sun 23 C 74 F Default Settings moon OFF Press large flame button to incr...

Page 13: ...ashes Press large flame button to set the hour Press large flame button to set the hour Press small flame button to set the minutes Press small flame button to set the minutes SETTING P1 ON TIME SETTI...

Page 14: ...appliance shuts off completely when it is continually in pilot position without any change for a period of 5 days Timer Programming Example default temperatures shown 6 00 a m P1 Start time 4 00 p m P...

Page 15: ...ll gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG VLGH 21 2 VZLWFK LQ 21 SRVL...

Page 16: ...ctrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 High Altitude Installations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4 500 fe...

Page 17: ...re hearth or floor in front of the fire place may become very hot when place may become very hot when the fireplace heats Do not use the the fireplace heats Do not use the hearth as a seat or shelf So...

Page 18: ...y Valve access panel X Y Dimensions Cavity Check that masonry step does not interfere with install dimensions or vent pipe If mantel is combustible see following section for allowable clearances A hea...

Page 19: ...n Finishing Materials Combustible materials Material such as wood compressed paper plant fibers plastics or any material capable of igniting and burning whether flame proofed or not plastered or un pl...

Page 20: ...w hits the outside vent terminal from any direction Check local codes for allowable vertical vent termination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vert...

Page 21: ...points must be considered before inserting the 785 into an existing fireplace cavity Generally no modifications are allowed to the existing fireplace that will compromise the integrity of the existin...

Page 22: ...ole of 1 5 inch 38 mm or less through the lower sides or bottom of the firebox The access hole must be plugged with non combustible insulation after the gas supply line has been installed See Dimensio...

Page 23: ...d before the appliance is fitted into the cavity Refer to instructions provided with the 795CFKV2 to install the fan Window Removal The window is held in place by a spring loaded lever on each side 1...

Page 24: ...s ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure with 4 tapping screws per liner If the vent slider was removed from the firebox slide the firebox onto the v...

Page 25: ...shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Failure to either disconnect or isolate the appliance during pressur...

Page 26: ...ere local codes do not permit the flex connector to be used inside the appliance case reconnect the flex connector outside of the appliance case A cut out is provided in the appliance case for this pu...

Page 27: ...e anchor back down to hold the panel The ceramic panels can be installed without removing the burner However you can remove the burner for additional space if desired 1 Remove the 2 screws fixing the...

Page 28: ...right hand end over the key in the ember bed Slide the log back until it rests against the vertical sheet metal edge 2 Place the left hand middle log in front of the rear log locating it over the key...

Page 29: ...t hand base log locating its notch on the key in the ember bed as indicated 6 Place the right hand middle log locating its notch on the key in the ember bed as indicated 7 Place the left hand cross lo...

Page 30: ...ht hand cross log locating its notch on the key on the top of the rear log as indicated Rest the front end of the log centered on top of the center base log Ensure the logs do not cover the burner hol...

Page 31: ...window seal 4 If the Hot Glass Warning plate has been removed from the front lower corner of the window reinstall it by sliding it between the glass and the frame as indicated below Window frame Bott...

Page 32: ...e battery box upside on the left of the firebox Battery box connection Reset button Battery box Remove cover Connect battery box to wire 5 With a sharp object press and hold the receiver s reset butto...

Page 33: ...warm up for 10 15 minutes to evaluate the flame picture Burners are equipped with an adjustable shutter to control primary aeration See the figures below The shutters are factory set to an aeration g...

Page 34: ...control handset is important to assure proper temperature regulation To obtain a constant temperature we recommend that the handset should be between 3 and 15 feet away from the appliance but not dire...

Page 35: ...ing Diagram Remote Battery Box Optional Fan 795CFKV2 Control Module Optional Wall Switch Kit 1265WSK Latching Solenoid Valve Red Yellow 4 AA Batteries GV60 Wiring Diagram Connector 35 QUALIFIED INSTAL...

Page 36: ...M 4CAA 4DCAB33 556CLA Co linear to Co axial Adapter 46DVA GK TM 4CTA 4DCAT33 Aluminum Flexible Liner 3 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufac...

Page 37: ...m other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not cover glass lo...

Page 38: ...Injector 51 NG 4000735 Pilot Injector 30 LPG 4000736 35 Pilot Tube 4000732 36 Pilot Hood 2 Flame 4000730 37 Extended Nut 4001855 38 Electrode 4001856 39 Insulation sleeve for ignition cable 4002244 C...

Page 39: ...4002365 b Enamel black 4002371EB c Ceramic fluted black 4002377 d Valor red brick 4002382 64 Right side panel a Ledgestone 4002366 b Enamel black 4002372EB c Ceramic fluted black 4002378 d Valor red...

Page 40: ...e Parts 65 43 44 45 46 47 48 49 50 60 61 62 63 64 51 58 59 57 56 55 54 53 52 1 2 3 7 8 9 10 12 14 15 13 11 16 23 25 26 17 18 19 19 21 22 20 32 38 42 F R 40 41 27a 27b 30 29 31 9 39 40 OWNER S INFORMAT...

Page 41: ...n provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model Num...

Page 42: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...

Reviews: